Re: Raspberry Pi with DCC++ and PR3 Stand-alone LocoNet
Solved.? Problem was with how the RPi assigns ports.? When only the DCC++ was connected it was assigned ttyACM0.? When two devices are connected the first one RPi recognizes is given port ttyACM0 and the second is ttyACM1.? When you plug in a 3rd device OR unplug a device and re-plug it that device will be given port ttyACM2, and so on.
So the RPi saw the port with the LocoNet first and assigned it port number ttyACM0.? I switched the ports in Preferences and the problem was solved.? This would make a great comment to add to JMRI help. Ken, thanks for suggesting the ports issue.? BTW the defaults were correctly assigned to DCC++. |
Locked
Re: propertyChangeListener
Thanks everyone - I created a class called runTask? and called it with the standard invocation? runTask.start() as Bob suggested and it worked for me.
Billybob - sorry did not know about the developers group so will go take a look at that for future reference.? class runTask(jmri.jmrit.automat.AbstractAutomaton) :
? ? ? def inti(self):
? ? ? ? ? return
? ? ? def handle(self):
? ? ? ? ?print(str(time.ctime())+" Run task runnning")
? ? ? ? ?time.sleep (15)
? ? ? ? ?print(str(time.ctime())+" Run Task finished")
? ? ? ? ?return
? |
Locked
Re: propertyChangeListener
James,
Your issue contains some deep programming issues and may not be of interest to the average jmriusers list member. The jmri-developers.groups.io list is more programming-oriented, and is a better fit for your issue. Regards, Billybob |
Locked
Re: propertyChangeListener
Take a look at the jython/BackAndForth.py sample script. (In the JMRI distribution or here: )
It creates an indepedent thread via the AbstractAutomaton class, which handles those details. That then waits for sensors and commands a throttle. For more: Bob On Jan 30, 2020, at 1:16 AM, James Anderson <james_anderson_999@...> wrote:-- Bob Jacobsen rgj1927@... |
Thanks Steve, the main problem has been resolved, actually quite simple, I had a turnout MT+N0E9 as well as MT+N0E09, same for E6 and E7.
Checking the turnout table in 4.14 only showed N0E9 and not N0E09 and I guess the new address validation in 4.18 quite correctly picked up on this. No idea why but could not delete the turnouts using the button in the table, clicking delete had no effect even though I had removed the signal heads associated with them, no error message, edited the XML and the panel now works with 4.18. PT5/6T-11T-PT7C-PT8T-PT9T etc. are just user names, the system name follows the standard JMRI / MERG naming convention. I use Logix to determine the state of the five turnouts, "PT5/6T-11T-PT7C-PT8T-PT9T"?will be Thrown if any of the turnouts are not set as required, setting PT5/6T-11T-PT7C-PT8T-PT9T to Closed changes the turnouts to the required position by sending a specific event e.g.+N0E103 which has been taught to each of the turnouts. Makes the Jython script a lot simpler, just one route to check and set. I used Node 0 as I thought this was necessary as the event is produced by the PC / JMRI but since learnt that I could used any node number providing it was not a duplicate. Thanks Pete |
Locked
Re: 4.17.3ish and csvreader
#scripting
Randall Wood
The release notes already cover how to use the old CSV API by linking into the documentation for setting JMRI parameters. The draft release notes for 4.19.3 are at |
Locked
Re: Raspberry Pi with DCC++ and PR3 Stand-alone LocoNet
Dave,
You should do the test of watching /dev while plugging and unplugging the devices. From the confused traffic, I would suspect that the picks might be reversed for the ports. ttyACM1 and ttyACM0 may not be the device you think it may be. Make sure of which name shows up when you plug in the device. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.org www.syracusemodelrr.org |
Locked
Re: Raspberry Pi with DCC++ and PR3 Stand-alone LocoNet
Dave,
You might want to check the Edit->Preferences->Defaults, it may not have the selections you think it should. It may have some things defaulting to the LocoNet that should be on the DCC++. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.org www.syracusemodelrr.org |
Locked
Re: Raspberry Pi with DCC++ and PR3 Stand-alone LocoNet
One more thing, on the PR3 the green LED is mostly on and winks off and the red LED is on solid indicating no LocoNet signal.? So yesterday I unplugged the BDL and plugged a LocoNet cable from a DCS50 Zephyr into the PR3.? The red LED went out, but the problem in JMRI with Unknown throttle was still there.
Below is the info from the System Console: 2020-01-08 10:37:26,686 util.Log4JUtil? ? ? ? ? ? ? ? ? ? ? ? INFO? - * JMRI log ** [main]
2020-01-08 10:37:27,292 util.Log4JUtil? ? ? ? ? ? ? ? ? ? ? ? INFO? - This log is appended to file: /home/pi/.jmri/log/messages.log [main]
2020-01-08 10:37:27,296 util.Log4JUtil? ? ? ? ? ? ? ? ? ? ? ? INFO? - This log is appended to file: /home/pi/.jmri/log/session.log [main]
2020-01-08 10:37:27,448 apps.Apps? ? ? ? ? ? ? ? ? ? ? ? ? ? ?INFO? - PanelPro version 4.18+R37ad3d0 starts under Java 11.0.5 on Linux arm v4.19.75-v7+ at Wed Jan 08 10:37:27 EST 2020 [main]
2020-01-08 10:37:35,364 apps.Apps? ? ? ? ? ? ? ? ? ? ? ? ? ? ?INFO? - Starting with profile DCC.3f4cd52a [main]
2020-01-08 10:37:36,067 node.NodeIdentity? ? ? ? ? ? ? ? ? ? ?INFO? - Using c6f3cdb0-4677-11e9-8000-b827eb71f7dc as the JMRI storage identity for profile id 3f4cd52a [AWT-EventQueue-0]
2020-01-08 10:37:37,251 xml.AbstractSerialConnectionConfigXml INFO? - Starting to connect for "DCC++" [main]
2020-01-08 10:37:38,058 serial.DCCppAdapter? ? ? ? ? ? ? ? ? ?INFO? - ttyACM0 port opened at 115200 baud with DTR: true RTS: true DSR: false CTS: true? CD: false [main]
2020-01-08 10:37:43,267 jmrix.AbstractMRTrafficController? ? ?WARN? - Timeout on reply to message: s consecutive timeouts = 0 in serial.SerialDCCppPacketizer [serial.SerialDCCppPacketizer Transmit thread]
2020-01-08 10:37:48,471 xml.AbstractSerialConnectionConfigXml INFO? - Starting to connect for "LocoNet" [main]
2020-01-08 10:37:48,590 pr3.PR3Adapter? ? ? ? ? ? ? ? ? ? ? ? INFO? - PR3 adapter set hardware flow control, mode=2 RTSCTS_OUT=2 RTSCTS_IN=1 [main]
2020-01-08 10:37:48,596 locobuffer.LocoBufferAdapter? ? ? ? ? INFO? - ttyACM1 port opened at 57600 baud with DTR: true RTS: true DSR: false CTS: true? CD: false [main]
2020-01-08 10:37:48,855 loconet.LnPacketizer? ? ? ? ? ? ? ? ? INFO? - lnPacketizer Started [main]
2020-01-08 10:37:49,087 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: 9B 9D [LocoNet receive handler]
2020-01-08 10:37:49,099 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,126 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: ee ended early. Expected length: 195 seen length: 2 unexpected byte: 9f [LocoNet receive handler]
2020-01-08 10:37:49,133 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: 9F 9F [LocoNet receive handler]
2020-01-08 10:37:49,138 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,155 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: c2 ended early. Expected length: 6 seen length: 2 unexpected byte: e6 [LocoNet receive handler]
2020-01-08 10:37:49,164 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: e6 ended early. Expected length: 255 seen length: 2 unexpected byte: 8c [LocoNet receive handler]
2020-01-08 10:37:49,171 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: 8C 10 [LocoNet receive handler]
2020-01-08 10:37:49,175 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,185 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: bd ended early. Expected length: 4 seen length: 2 unexpected byte: c8 [LocoNet receive handler]
2020-01-08 10:37:49,196 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: c8 ended early. Expected length: 6 seen length: 3 unexpected byte: b8 [LocoNet receive handler]
2020-01-08 10:37:49,205 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: B8 28 31 29 [LocoNet receive handler]
2020-01-08 10:37:49,209 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,225 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: c4 ended early. Expected length: 6 seen length: 5 unexpected byte: 80 [LocoNet receive handler]
2020-01-08 10:37:49,232 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: 80 48 [LocoNet receive handler]
2020-01-08 10:37:49,237 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,247 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: c8 ended early. Expected length: 6 seen length: 2 unexpected byte: c8 [LocoNet receive handler]
2020-01-08 10:37:49,256 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: c8 ended early. Expected length: 6 seen length: 2 unexpected byte: c8 [LocoNet receive handler]
2020-01-08 10:37:49,271 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: C8 D6 08 48 08 0A [LocoNet receive handler]
2020-01-08 10:37:49,275 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,284 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: 88 0E [LocoNet receive handler]
2020-01-08 10:37:49,288 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,299 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - LocoNet message with opCode: cc ended early. Expected length: 6 seen length: 2 unexpected byte: 8e [LocoNet receive handler]
2020-01-08 10:37:49,306 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: 8E 06 [LocoNet receive handler]
2020-01-08 10:37:49,311 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:49,326 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - Ignore LocoNet packet with bad checksum: 9E D6 [LocoNet receive handler]
2020-01-08 10:37:49,331 loconet.LnPacketizer? ? ? ? ? ? ? ? ? WARN? - run: unexpected LocoNetMessageException: {} [LocoNet receive handler]
jmri.jmrix.loconet.LocoNetMessageException
at jmri.jmrix.loconet.LnPacketizer$RcvHandler.run(LnPacketizer.java:317)
at java.base/java.lang.Thread.run(Thread.java:834)
2020-01-08 10:37:52,776 withrottle.FacelessServer? ? ? ? ? ? ?INFO? - Published ZeroConf service for 'rpi-jmri dcc++._withrottle._tcp.local.' on 192.168.6.1:12090 [WiThrottleServer]
2020-01-08 10:37:52,782 withrottle.FacelessServer? ? ? ? ? ? ?INFO? - Creating new WiThrottle DeviceServer(socket) on port 12090, waiting for incoming connection... [WiThrottleServer]
2020-01-08 10:37:53,132 jmrix.AbstractMRTrafficController? ? ?WARN? - Timeout on reply to message: s consecutive timeouts = 1 in serial.SerialDCCppPacketizer [serial.SerialDCCppPacketizer Transmit thread]
2020-01-08 10:37:54,227 server.WebServer? ? ? ? ? ? ? ? ? ? ? INFO? - Starting Web Server on port 12080 [WebServer]
2020-01-08 10:37:57,244 simpleserver.SimpleServer? ? ? ? ? ? ?INFO? - JMRI SimpleServer started on port 2048 [AWT-EventQueue-0]
2020-01-08 10:37:57,267 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path program: is /home/pi/JMRI/ [main]
2020-01-08 10:37:57,272 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path preference: is /home/pi/JMRI_UserFiles/ [main]
2020-01-08 10:37:57,276 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path profile: is /home/pi/.jmri/DCC/ [main]
2020-01-08 10:37:57,281 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path settings: is /home/pi/.jmri/ [main]
2020-01-08 10:37:57,285 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path home: is /home/pi/ [main]
2020-01-08 10:37:57,288 util.FileUtilSupport? ? ? ? ? ? ? ? ? INFO? - File path scripts: is /home/pi/JMRI_UserFiles/jython/ [main]
2020-01-08 10:38:00,997 server.WebServer? ? ? ? ? ? ? ? ? ? ? INFO? - Starting ZeroConfService _http._tcp.local for Web Server with properties {path=/, json=5.2.0} [WebServer]
2020-01-08 10:38:02,813 PanelPro.PanelPro? ? ? ? ? ? ? ? ? ? ?INFO? - Main initialization done [main]
2020-01-08 10:38:05,859 jmrix.AbstractMRTrafficController? ? ?WARN? - Timeout on reply to message: 0 consecutive timeouts = 2 in serial.SerialDCCppPacketizer [serial.SerialDCCppPacketizer Transmit thread]
2020-01-08 10:38:10,865 jmrix.AbstractMRTrafficController? ? ?WARN? - Timeout on reply to message: 0 consecutive timeouts = 3 in serial.SerialDCCppPacketizer [serial.SerialDCCppPacketizer Transmit thread]
2020-01-08 10:38:18,275 jmrix.AbstractMRTrafficController? ? ?WARN? - Timeout on reply to message: 0 consecutive timeouts = 4 in serial.SerialDCCppPacketizer [serial.SerialDCCppPacketizer Transmit thread]
? |
Locked
propertyChangeListener
Hi, I have included a small cut down version of something I am trying to do.? I set up a propertyChangeLlistener for a sensor. When the sensor is activated it runs. I have simulated it running a long time just by putting a time.sleep in. Is there a way to have the propertyChageListener run without the main function waiting for it to complete. Thanks jim. ?Code? import jmri class _SET_SENSOR(jmri.jmrit.automat.AbstractAutomaton) : ? ? def init(self): ? ??? def handle(slef): ? class _LISTENER(java.beans.PropertyChangeListener): test=_SET_SENSOR() ? OUTPUT from script |
Locked
Re: help with creating xml decoderfile [solved]
Thanks for the help!
I created the Decoder File for the Digital Bahn WaLD Decoder and it works. So from now on, i can set up the interior lightning stripe with decoder right aut of jmri. I think, i will upload the files to the projekt, so everyone can use them in future. |
Locked
Raspberry Pi with DCC++ and PR3 Stand-alone LocoNet
I have a small track that has been successfully running DCC++ connected to a Raspberry Pi currently running PanelPro 4.6.? I am attempting to add block detection using a BDL168 and PR3.? I use TightVNC on a laptop for programming the RPi.
First, the track was cut into 16 blocks with feeders thru the BDL and the train ran normally.? Next, BDL OpSw 12 was set to "t" to terminate the LocoNet, and track power from Rail A was connected to pin 6 on the LocoNet to provide a RailSync signal per the BDL manual. Opened Preferences to add a second connection: Mfr - Digitrax; Connection - LocoNetPR3; Serial port - /dev/ttyACM1; Cmd station - Stand-alone LocoNet.? Saved and restarted. The console window shows -? Active profile: DCC++ DCC++: using DCC++ Serial port on /dev/ttyACM0 LocoNet: using LocoNet PR3 on /dev/ACM1 The track power button is stuck on "Unknown".? Removed and added the PR3 to Preferences a couple of times with the same results.? Tried Steve Todd's latest image v4.18 with the same results. What am I missing?? Where do I look next.? It's probably something simple that I have overlooked. Thanks for any help or suggestion you may be able to offer. Dave |
Locked
Re: Working offline with version 14
John, Yes, as long as the "User Files Location" for both profiles have the exact same file path. ?If you are also doing decoder programming, you want to make sure the "Roster Location" for each profile matches. Use "Help >> Locations..." to see the current location information. If you go to Preferences >> Config Profiles, at the bottom of the screen you can enable "Show profile selector". ?This makes it easy select the proper profile based on the layout connection state. Dave Sand ----- Original message ----- From: John <gross144john@...> Subject: Re: [jmriusers] Working offline with version 14 Date: Wednesday, January 29, 2020 9:22 PM So, once a simulator protocol is created, I can move back and forth between online and offline mode without losing any of the programming that has been done as long as I switch to simulator mode when opening panel pro offline? Thank you, John On Wed, Jan 29, 2020 at 5:10 PM Dave Sand <ds@...> wrote:
|
Locked
Re: CV48
#esu-decoders
CV163 to value 4 did the trick. Thank you to all who replied now to fix that caboose LOL On Wed, Jan 29, 2020 at 1:24 PM Dave Heap <dgheap@...> wrote: David, --
David Epling Nevada Pacific Custom Model Trains & Repair Stockton CA |
Locked
Re: Working offline with version 14
John
So, once a simulator protocol is created, I can move back and forth between online and offline mode without losing any of the programming that has been done as long as I switch to simulator mode when opening panel pro offline? Thank you, John On Wed, Jan 29, 2020 at 5:10 PM Dave Sand <ds@...> wrote:
|
Locked
Re: No serial port found
#locobuffer-usb
#windows10
Are drivers installed for the LocoBuffer?
-- Peter Ulvestad JMRI Users Group Moderator - ( ) Tam Valley Group Moderator - ( ) Sprog-DCC Group Moderator - ( ) Edmonton Model Railroad Association - |
Locked
No serial port found
#locobuffer-usb
#windows10
New to group and this may have been covered before, if so can someone direct me where to look. I have the latest jmri and java installed on a new Laptop using Windows 10. JMRI works correctly but I cannot connect to the layout; I am using a Digitrax DCS100 and LocoBuffer-USB combination that has worked on older setups but with the latest equipment I get the message "no serial port found" What can I do to find a serial port? Jim Dickinson |