Dear testers,
I have just downloaded the current test version of JMRI as you can see by the title. ?I have had a look to see what ‘Cabs’ are on my NCE Powercab handset and can only set the current cab in use. ?Is it possible to show more cabs on a single handset please as I can RECALL upto 6, thank you.? Kind regards Duncan Hamilton |
Locked
Re: What would it take to enable "read full page" with Programming on the main? (when capable). Anyone have thoughts about thish?
Scott
Using Roco I can read all / read sheet, but, I cannot read any indexed CV. Steve G. |
Locked
Position and size of windows
What determines the position and size of windows in jmri? At some point the positions and sizes were recorded. Now no matter how much I reposition and resize windows, saving using "store all tablets content and panels", nothing changes and remains with some past definition
|
Tim Kelley
Good morning,
I am in the planning stages of my layout. I am currently trying to figure out where I need to place my "blocks". I am using all Digitrax hardware including a Digitrax BXP88 for power management and also block occupancy detection. I believe the BXP88 reports block occupancy status to LocoNet. I'm also using Peco ElectroFrog turnouts. I've watched some videos on youtube and I'm thinking of setting up my Peco ElectroFrog turnouts so that each one of those turnouts is it's own individual block. I'm planning to use JMRI software for running my layout and someday maybe CATS software. Someday I plan on adding signals to my layout. I believe there are a couple of different ways of wiring up the Peco ElectroFrog turnouts. So should I plan on setting up my turnouts so that each one of them is it's own block? What do you guys think? Is that the best plan? Thanks, Tim |
Locked
Re: I have apparently created a loop or message storm in Loconet - I don't know if it's JMRI or not -- any suggestions on how to diagnose?
Douwe, The send count option is only applicable to signal mast drivers that talk directly to the layout, such as the "DCC Signal Mast Decoder". ? ? Dave Sand ----- Original message ----- From:?douwe@... Subject: Re: [jmriusers] I have apparently created a loop or message storm in Loconet - I don't know if it's JMRI or not -- any suggestions on how to diagnose? Date: Monday, May 01, 2023 10:47 AM I followed this discussion and was triggered by the comment that you can set the number of 'send counts' to a mast. ? -- Douwe |
Thanks Tim. My decoders are not locked. I will lock them when I figure it out. Mark. On Mon., May 1, 2023, 11:39 a.m. Tim Kelley, <tim.kelley@...> wrote: Good morning Mark, --
MARK TAYLOR |
Locked
Re: I have apparently created a loop or message storm in Loconet - I don't know if it's JMRI or not -- any suggestions on how to diagnose?
I followed this discussion and was triggered by the comment that you can set the number of 'send counts' to a mast. ? -- Douwe |
Since this is a decoder issue and not JMRI you should take your questions to the TCS group.
/g/TCS-Users -- Peter Ulvestad JMRI Users Group Moderator ( ) Tam Valley Group Moderator ( ) Sprog-DCC Group Moderator ( ) Edmonton Model Railroad Association ( ) |
Tim Kelley
Good morning Mark,
I have 3 TCS WOW-121 Steam Decoders. I think they are very similar. Sometimes hickups can happen on the rails and the decoders can sometimes interpret them as programming commands. I have been "LOCKING" all of my TCS WOW-121 Steam Decoders. That way they are locked and will NOT accept any programming commands. When the time comes and you want to make programming changes to the decoders you can then unlock them to make the CV changes. I know this doesn't exactly answer your question right now but it might avoid some future problems down the road. Good luck! Tim |
Hello group.
I have a question about this decoder. I have 2 GP38's that are consisted together. I have not run these 2 locos for a week or so. --Today when I started to run this consist the locos ran for about 15 seconds and the one loco stopped moving. Before it stopped there was a beeping sound for about 5 seconds. When I turn the throttle to 0 and then turn the throttle up again the loco that beeps and stopped, now sounds like a brake release and starts moving again. Then about 15 seconds later it beeps and stops. I use JMRI for programming and these two locos are programmed the same. They have been running together for 3 years. Seems strange how this happened. Any thoughts would be appreciated. Thanks, MARK TAYLOR |
On Mon, May 1, 2023 at 07:33 AM, <stephenjohnson500@...> wrote:
I'll give that new version of the sketch a go when I get back from work tonight. If it is okay, which I'm sure it will be, then is it possible to modify it for the PN532 readers? There is a slight problem with the existing PN532 sketch, but I was waiting to get the MFRC522 Ethernet/Serial sketch sorted first.?Steve, I have a jumpstart already on the PN532 version, so yes, we can tackle the Ethernet/Serial version of that one next! :-) Tom |
Locked
Re: Jmri printing issue
#operationspro
Try only printing the 1st page when the printer popup window appears.? If that doesn't work, print to pdf, and only print the 1st page.
|
Locked
Re: Jmri printing issue
#operationspro
Thanks I went there but it won’t let me print just this page even though I select to print inly on this page. It will only print 16 pages, which includes all the train info for all trains listed. I just need the train list sheet.? What am I missing? Frank Kenny
Central Pacific Railway - CPRX
310-344-9145
Los Angeles area
Instagram:?
Facebook:?
Blog:?? ?(Updated occasionally)
|
Locked
Team track
#operationspro
Gentlemen,?
I wish to set up a team track. this track will have multiple industries.? my dilemma is, I wish to have each industry listed individually as far as set-out and pickups go. example,? team track is called Lakeville spur,? industry is Ryan's Rebar,? I would like the train Manifest to read something like flat 123, destination Lakeville spur, set-out Ryan's Rebar.? how is the best way to go about this? John? -- Sent from my gosh darn droid! Please excuse the fat finger mistakes... John |
Ethernet/Serial
Tom I'll give that new version of the sketch a go when I get back from work tonight. If it is okay, which I'm sure it will be, then is it possible to modify it for the PN532 readers? There is a slight problem with the existing PN532 sketch, but I was waiting to get the MFRC522 Ethernet/Serial sketch sorted first.? I can then try the two Ethernet Uno's with different readers as network connections into JMRI and see how that goes. Steve |
On Mon, May 1, 2023 at 03:26 AM, <stephenjohnson500@...> wrote:
Here was me thinking it might be an easier option! Lol!Steve, No, you are completely correct in your summation of how the board works. It IS 2 boards in 1, operating exactly as you described. We can certainly give it a go though! :-) Tom |
开云体育You should be able to. ?They’re DCC decoders so once set up, they should work on any DCC system. You just need to know the decoder’s address.Mick ________________________________ Mick Moignard m: +44 7774 652504 Skype: mickmoignard The week may start M,T but it always ends WTF. |
On Mon, May 1, 2023 at 12:28 AM, Thomas Seitz wrote:
On Sun, Apr 30, 2023 at 07:17 PM, <stephenjohnson500@...> wrote:Tom Here was me thinking it might be an easier option! Lol! Interesting article though. Apart from the hassle programming it, it basically looks like two units on one board. From what I can see, the Uno part can use the standard Serial tag reading sketch. The ESP would need it's own sketch to set WiFi Credentials and TX/RX. Then surely the Uno would just send/recieve data via the internal serial connection from the ESP? Or is that just an over simplistic view? Lol! Steve |