Keyboard Shortcuts
Likes
- Jmriusers
- Messages
Search
Locked
Re: cmri turnout
HP:
The common here is the power to the SUSIC-I/O "ground" (-) is connected to the power (-) of the switch controls boards. If not the same power supply a 5VDC for the SUSIC and 12VDC for the switch board. Salvaged computer supply with both will have a common. Maybe a -5 or -12 if old enough so beware my (-) minus sign! The data lines pull to low (-) to activate so if that is not common the switch boards don't see a command to change their output. Inputs too when you get there. Should that be in place and solid... The only thing I'm not sure of with your description is the almost solid data in LED (yellow) I'm like Ken, it's been too long... these things just work... that I diagnosed a node... Data out red should be very active if you have the input table open to watch the inputs but I thought the in should only blink when you change something.;.? Try closing one and the other and see if the data lights change. Another test is a temporary loop back of one output to one input... since the inputs work... Pin one to pin one watch the input and change the output. Jim Albanowski |
Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
¿ªÔÆÌåÓýI am going down the Lenz route. Just changing over from ZTC.
|
Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
"What about the new Peco Servo Kit?"
Way over priced for a servo, toggle switch and a couple of bits of bent metal. Check out the price of servos on Ebay or Hobbyking. You will need a module to control servos from either DCC or a Layout Control Bus (LCB) such as Merg's CBus. |
Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
¿ªÔÆÌåÓýIan,I will be looking into this shortly for my layout. What about the new Peco Servo Kit? Dave
|
Locked
Re: Change Turnout on my Layout
Hello from Paris!
?
THANK YOU ! ! !
?
The solution was so simple under my nose that I did not see it (French expression).
?
Yet used so often right click I had not thought.
?
Thanks again !
?
For the update 4.14 I will think about it too.
?
I'm listening to this super group, we learn so much :-)
?
Next step change the appearance of turnouts between closed and thrown.
?
I wish you all a wonderful Christmas! ! ! |
Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
do a kit for a replacement PCB to fit Dapol semaphore signals so that they operate more logically, with a simple on-off switch, or logic level. This means JMRI and the signal position will always be in sync. It is quite fiddly to make and fit, so I would not recommend it to a beginner with a soldering iron, but it does work well.
I never did understand why Dapol went for the current arrangement where a pulse changed the signal position, and another pulse changed it back again, giving no indication of which position it moved from and to. Ian Morgan Hampshire UK |
Locked
Re: cmri turnout
suggestions for common ground check??
only see this repeated over and over : Poll ua=0
Receive ua=0 IB=FF FF FF FF 0 0 20 0 |
Locked
Re: Engine Roster ?
With a large roster, I recommend opening the JMRI System Console (from the Help menu) and after clicking on "Rebuild Roster", watch that window for the "Roster rebuilt, stored in..." message. If no errors on the way, quit and restart JMRI to ensure the new index is picked up by the Roster screen.
toggle quoted message
Show quoted text
-- Dave in Australia On 24 Dec 2018, at 2:06 PM, Marc <forfoum@...> wrote: |
Locked
Re: cmri turnout
No need to test this. The node is responding to the polls, so the address is correct, wiring is right, etc.
If the C/MRI card configuration is right (which is likely if the polling is working), then I¡¯d suspect that the output wiring (i.e. from not to turnout) has a problem. Perhaps no common ground? Bob On Dec 23, 2018, at 9:51 PM, Ken Cameron <kcameron@...> wrote:-- Bob Jacobsen rgj1927@... |
Locked
Re: Operations: trains to and from staging
Ok Dan,? I¡¯m almost there I¡¯ve now got it so it pulls all the Car Float cars and routes them to Storage. BUT, It won¡¯t move any cars back to the float because the float tracks don¡¯t have the space as they still show occupied by the cars that will be picked up.? I see in the instructions where you can set Planned Pickups to 100 % so it will send the 8 cars to the float even though 8 still show there.? But I can¡¯t find where to enter that percentage.? And if I do is that percentage by location or by train/route???Because I don¡¯t want to overload the Float during normal train operations only during storage swaps. This is the build report for each car in storage that it would not send to the float ? Find destinations for (GACX 50138) type (Hopper Plast) load (E) at (Storage off layout, off layout) ??? Searching location (Car Float) route id (11r5) for possible destination ??? Can't send (GACX 50138) to yard (overflow track) due to rolling stock length 54 feet, available track ??? space 48 feet ??? Can't send (GACX 50138) to yard (Float) due to rolling stock length 54 feet, available track space 26 ??? feet ?? Could not find a track for (GACX 50138) at destination (Car Float) ?? Did not assign a destination for car (GACX 50138) |
Locked
Re: cmri turnout
Hp,
Sounding good so far, the outbound message will change as soon as you alter one or more turnouts. My usual test is to set the first couple of even turnouts to normal and the odd turnouts to reverse (closed and thrown for some people). It should put out a pattern. Then change the turnouts to swap the positions. The pattern should change. One catch, as I recall JMRI will only send the output message when something changes in JMRI, OR if JMRI thinks the node might have reset (timeout to a poll for example). I used to know that part better, but I've not had to look at a traffic trace for CMRI in a couple of years, so I've forgot if it repeats the outputs or not. But my usual guess is if the dip switch is mounted the wrong way, the on/off relation gets messed up and you are not addressing the board like you think you are setting. So I usual give it a try where I flip them all the other way. I mean if I thought they should be off-off...-on, I also try on-on-...-off. Worth a shot. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.com www.syracusemodelrr.org |
Locked
Re: Layout Editor issues
Don,
? ?If you are zooming out on your Layout Editor, it's hard to move objects for some reason.? Go back to 100%. Roger |
Locked
Re: cmri turnout
yes cs1 thru cs64? ?... sensors are working ...
yes outputs labeled ct1 thru ct32 ... the following is the only messages on the CMRI monitor (repeated constantly) ... Poll ua=0
Receive ua=0 IB=FF FF FF FF 0 0 20 0 susic green light - blinking ? ? ? ? ?yellow light - steady? ? ? ? ? ? ? ?red light - steady rs232 to rs485? ? ?red light - fast blinking (basically steady) ?yellow light - fast blinking (basically steady) 32 bit output card - address 0 32 bit input card - address 1 32 bit input card - address 2 |
Locked
Re: Engine Roster ?
¿ªÔÆÌåÓýI clicked on rebuild roster, after that the screen went back to the window that reads at top decoder pro. New loco, identify, help. Is it working? ?I can¡¯t tell? ?Is that all you need to do. ?Thanks Russ Austin On Dec 23, 2018, at 7:00 PM, Dave Heap <dgheap@...> wrote:
|
Locked
Re: Using Dapol semaphore signals signalist sc1 and dp8
Hi Wrightstuart...
The Dapol semaphores are just a 2-aspect when connected this way. You can just configure each arm using the single output driver as either head or mast (or head controlled mast) with Green (off or inclined) and Red (on or horizontal home) or Yellow (caution or horizontal distant). Once synchronised with the button on the DP8 the signal arm should follow the state in JMRI as long as the signal is powered while JMRI is in use. If you have used BR2003 colour lights then you should have no problem using the Dapol semaphores. Splitting signal masts get a bit more complicated, but I suspect you do not have any of them yet. Suzie x |
Locked
Re: Engine Roster ?
¿ªÔÆÌåÓýRuss, Have you tried Recreate/Rebuild Roster Index? This rebuilds the "roster.xml" file to an index of the actual loco files in the "roster" folder found at Roster Location. Note that: - The rebuild takes a while. Its completion is announced in the JMRI System Console. - You'll probably need to restart JMRI to see the results of the rebuild. - The "roster.xml" file is not your roster. It's just the index to your individual roster files. They are what is important. - Don't confuse "Recreate/Rebuild Roster Index" with "Recreate/Rebuild Decoder Index". You don't need to do the decoder index. It won't help you and may create other problems. --? Dave in Australia On 24 Dec 2018, at 6:51 AM, Marc <forfoum@...> wrote:
Open? HELP and then open LOCATIONS, cut and paste a screen capture into this thread.? |
Locked
Re: Layout Editor issues
3. Delete is the correct option. This deletes the panel from your current run of JMRI and NOT from your files. You can just reopen the panel again if you want without the need to restart JMRI.
-- Peter Ulvestad JMRI Users Group Moderator - ( ) Tam Valley Group Moderator - ( ) Sprog-DCC Group Moderator - ( ) Edmonton Model Railroad Association - |
Locked
Re: Layout Editor issues
Don,
toggle quoted message
Show quoted text
1. Select the group, use "Tools >> Translate (Move) Selection¡±. This allows you to set the precise move distance. 3. Exit JMRI to close without saving. A panel is not an independent item. 4. Turn off "Options >> Grid Options >> Snap to Grid when Moving¡±. I used to always enable snap to grid for adding and moving. I now leave those options off and use a key combination that enables temporary snap to grid. On macOS, the combination is option-command. I don¡¯t know the combinations for Windows or Linux. Dave Sand On Dec 23, 2018, at 4:05 PM, Don Weigt <dweigt47@...> wrote: |
Locked
Re: WiThrottle Roster display of non decoder entries
¿ªÔÆÌåÓýRoger, ? If you look at the right side of the WiThrottle Server window, you will see a pull-down menu indicating the roster group that is displayed by Engine Driver and WiThrottle. You can define a roster group in DecoderPro and then check entries you want displayed and don¡¯t check entries you do not want displayed. ? Mark Granville |