Hi Tim,

I have tested your panel file using a?simulated Loconet connection and simulated OpenLCB connection.
These simulated connections are to represent a layout connection when you've got no physical connection, enabling you to work with the layout offline.
PanelPro > Edit > Preferences > Connections > + >
OpenLCB / CAN Simulation
Digitrax / LocoNet Simulator

With your panel, I'm seeing OpenLCB Light flickering with v4.17.3
I am NOT seeing the flickering with v4.17.4 ( actual 4.17.4, not an ish )

If I'm not able to recreate them with the OpenLCB Simulator, it'll definitely need someone with more OpenLCB experience than me to assist.

Steve.


Locked Problem to reset slots with JMRI

 

We are running JMRI V 4.17.4 and Digitrax DCS 240. Closing OpSw 36 with JMRI has no effect on the command station. To clear all slots we must use the loco reset button on the DCS 240. Is there any setting we overlooked.

Jacques


Locked Re: SECTIONS TABLE NEW BUG

 

Mitch,

? ? ?Delete the section the sensor is working with then try to delete the sensor.? I've seen a few cases during recent JMRI versions where the programmers would not let you delete an item until it's associations had been severed.?

Roger


Locked Re: SECTIONS TABLE NEW BUG

 

Any ideas, anyone?
--
Thanks
Mitch


Locked Re: Issue with Engine Driver and functions

 

Thomas,
Any progress on this?
--SteveT


Locked Turnouts work only in Edit mode

 

The 4 new points I installed only work when My Layout is in edit mode.
Any idea what I have done wrong?

Thanks for all your help.?
PanelPro 4.16
RasPi
Java 1.8.0-65
Switch 8 to Tortoise motors
Insufrog points


Locked Possible roster problem #zimo

 

You may recall I have been unable to control old Lenz LE103 decoders with JMRI throttles, although I can control newer basic NCE decoders and SoundTraxx Econami steam decoders, at least the one of each I've tried so far.

The LE103s are controllable with my EasyDCC throttles, including the light function. Neither their throttles or the lights can be controlled via JMRI.

The NCE and Econami decoders throttles and functions can be controlled by EasyDCC throttles or JMRI. So, it is puzzling that all aren't controllable with JMRI.

Tonight I got a new data point. I finished servicing an engine with an old Zimo MX-61 or MX-62 decoder. It also works fine with an EasyDCC throttle, including functions. I had hoped JMRI would be able to control it. First indication was good, as I could toggle a function on and off. But, when I advanced the throttle, nothing happened. I can control its functions, but not its speed! This got me to wondering about the roster entry. Might the problems with this Zimo and with all my LE103s be due to something wrong in their roster entries?

Since the Zimo was working on EasyDCC throttles, I didn't program it with DecoderPro, just tried to create an appropriate roster entry. Perhaps there is some setting needed to make the throttle work right, that I don't understand? Might there be such a thing even with basic Lenz LE103s? The EasyDCC tech support person told me that they've never heard of a problem with EasyDCC and Lenz decoders. Said to see my "JMRI manufacturer." Hah!

I plan to revisit the DecoderPro help to carefully review what I'm trying to do. Maybe I have been making some beginner mistake? I would appreciate knowing if this sounds like a worthwhile step to you experts! Did anyone have an "Ah hah!" moment reading this?

Don Weigt
RPi 3B+ running Steve Todd's JMRI image
Connecticut, USA


Locked Re: Signal Mast Appearance definition file

 

"Haltz" (or whatever "friendly name" you would prefer),

Setting up JMRI "signal mast logic" _does not require_ that you modify any "Signal Mast Appearance definition file" if you are using one of JMRI's pre-defined "Signaling Systems".

If you are using a pre-defined "Signaling System", have you looked at the "JMRI: Signaling Quickstart" page ( )? This may be a better place to look for help on setting up some signaling than the "JMRI Signal Mast Logic" page.

If you are indeed creating a new "Signaling System", then it will be necesasry necessary to create one or more "Signal Mast Appearance definition files". Information on this may be found in the "JMRI: Defining your own Signaling System" page ( ). "Signal Mast Appearance definition files" are part of the "Signaling System" files. File location information for "Signaling System" files may be found in the first paragraph of the "Creating a new Signaling System" section of the "JMRI: Defining your own Signaling System" page.

Regards,
Billybob


Locked Re: NCE PowerPro Connection Issues

 

¿ªÔÆÌåÓý

Hi Jeff

?

You said the USB to Serial cable worked in your mate¡¯s computer, that confirms the Cable is okay.

From your Console Log, it shows COM 3.

Make sure you are using the SAME USB Port on your computer each time.

?

With Decoder Pro showing the Roster page:

Select the Edit Tab, then

Select the Preferences Tab, then

Select Defaults on the Drop Down window.

?

Make sure ALL selections are ¡°ticked¡± for NCE and not Internal.

?

If you made any changes, make sure you select SAVE at the L/H bottom.

?

As others have said, maybe you need to upgrade from 4.16

?

If it still does not work, check your ¡°Serial¡± connection using this page:

?

?

Regards

Marcus

??

?

From: [email protected] [mailto:[email protected]] On Behalf Of Jeff Mutter
Sent: Thursday, 19 September 2019 5:58 AM
To: [email protected]
Subject: [jmriusers] NCE PowerPro Connection Issues

?

Hello Everyone,

I have an NCE PowerPro connected to a Dell laptop (Win10)?using a serial-USB adapter cable.? Command station version is 19:08 Mar 1, 2007C.? I have had intermittent luck connecting to DecoderPro/PanelPro; to try and fix it I just upgraded to JMRI version 4.16 and still have the problem.

When I start PanelPro, if the system finds the COM port (which is about half the time, but I think that's another issue), I get the green "connected" message at the bottom of the DecoderPro/Roster screen.? However, after about 30 seconds it drops the connection and I get the red "not connected" message.? I've checked baud rate (9600 in both the command station and JMRI) and?NCE's AIU Broadcast (off).? JMRI is set to NCE command station version 2006 or later.? I read the recent NCE USB thread but that seemed to apply to the USB-PowerCab system.

Please help!? Here is the system log from my last attempt:

2019-09-18 15:23:03,219 util.Log4JUtil??????????????????????? INFO? - * JMRI log ** [main]
2019-09-18 15:23:03,235 util.Log4JUtil??????????????????????? INFO? - This log is appended to file: C:\Users\Jeffrey Mutter\JMRI\log\messages.log [main]
2019-09-18 15:23:03,235 util.Log4JUtil??????????????????????? INFO? - This log is stored in file: C:\Users\Jeffrey Mutter\JMRI\log\session.log [main]
2019-09-18 15:23:03,250 apps.Apps???????????????????????????? INFO? - PanelPro version 4.16+R6f9aced starts under Java 1.8.0_201 on Windows 10 x86 v10.0 at Wed Sep 18 15:23:03 EDT 2019 [main]
2019-09-18 15:23:06,105 apps.Apps???????????????????????????? INFO? - Starting with profile My_JMRI_Railroad.3ee7110a [main]
2019-09-18 15:23:06,401 node.NodeIdentity???????????????????? INFO? - Using 08fea99e-6b01-44fe-8e8b-1bbc47625414 as the JMRI storage identity for profile id 3ee7110a [AWT-EventQueue-0]
2019-09-18 15:23:06,522 xml.AbstractSerialConnectionConfigXml INFO? - Starting to connect for "NCE" [main]
2019-09-18 15:23:07,309 serialdriver.SerialDriverAdapter????? INFO? - NCE COM3 port opened at 9600 baud [main]
2019-09-18 15:23:07,695 util.FileUtilSupport????????????????? INFO? - File path program: is C:\Program Files (x86)\JMRI\ [main]
2019-09-18 15:23:07,695 util.FileUtilSupport????????????????? INFO? - File path preference: is C:\Users\Jeffrey Mutter\JMRI\My_JMRI_Railroad\ [main]
2019-09-18 15:23:07,695 util.FileUtilSupport????????????????? INFO? - File path profile: is C:\Users\Jeffrey Mutter\JMRI\My_JMRI_Railroad\ [main]
2019-09-18 15:23:07,710 util.FileUtilSupport????????????????? INFO? - File path settings: is C:\Users\Jeffrey Mutter\JMRI\ [main]
2019-09-18 15:23:07,710 util.FileUtilSupport????????????????? INFO? - File path home: is C:\Users\Jeffrey Mutter\ [main]
2019-09-18 15:23:07,710 util.FileUtilSupport????????????????? INFO? - File path scripts: is C:\Users\Jeffrey Mutter\JMRI\My_JMRI_Railroad\ [main]
2019-09-18 15:23:08,080 PanelPro.PanelPro???????????????????? INFO? - Main initialization done [main]
2019-09-18 15:23:17,450 jmrix.AbstractMRTrafficController???? WARN? - Timeout on reply to message: AA consecutive timeouts = 0 in nce.NceTrafficController [nce.NceTrafficController Transmit thread]
2019-09-18 15:23:17,550 nce.NceConnectionStatus?????????????? WARN? - Incorrect or no response from NCE command station [nce.NceTrafficController Transmit thread]
2019-09-18 15:23:17,550 jmrix.AbstractMRTrafficController???? WARN? - sendMessage: Exception: In jmri.jmrix.nce.NceTrafficController port warn:? [nce.NceTrafficController Transmit thread]
java.io.IOException
?at purejavacomm.PureJavaSerialPort$1.write(PureJavaSerialPort.java:642)
?at java.io.DataOutputStream.write(Unknown Source)
?at java.io.FilterOutputStream.write(Unknown Source)
?at jmri.jmrix.AbstractMRTrafficController.forwardToPort(AbstractMRTrafficController.java:690)
?at jmri.jmrix.nce.NceTrafficController.forwardToPort(NceTrafficController.java:494)
?at jmri.jmrix.AbstractMRTrafficController.transmitLoop(AbstractMRTrafficController.java:475)
?at jmri.jmrix.AbstractMRTrafficController$1.run(AbstractMRTrafficController.java:771)
?at java.lang.Thread.run(Unknown Source)
2019-09-18 15:23:17,550 jmrix.AbstractMRTrafficController???? ERROR - run: Exception: java.io.IOException in class jmri.jmrix.nce.NceTrafficController [nce.NceTrafficController Receive thread]
java.io.IOException
?at purejavacomm.PureJavaSerialPort$2.read(PureJavaSerialPort.java:887)
?at java.io.DataInputStream.read(Unknown Source)
?at jmri.jmrix.AbstractMRTrafficController.readByteProtected(AbstractMRTrafficController.java:947)
?at jmri.jmrix.AbstractMRTrafficController.loadChars(AbstractMRTrafficController.java:978)
?at jmri.jmrix.AbstractMRTrafficController.handleOneIncomingReply(AbstractMRTrafficController.java:1050)
?at jmri.jmrix.AbstractMRTrafficController.receiveLoop(AbstractMRTrafficController.java:871)
?at jmri.jmrix.AbstractMRTrafficController$2.run(AbstractMRTrafficController.java:795)
?at java.lang.Thread.run(Unknown Source)
2019-09-18 15:23:17,550 jmrix.AbstractMRTrafficController???? ERROR - Exit from rcv loop in class jmri.jmrix.nce.NceTrafficController [nce.NceTrafficController Receive thread]
2019-09-18 15:23:27,552 jmrix.AbstractMRTrafficController???? WARN? - Timeout on reply to message: AA consecutive timeouts = 1 in nce.NceTrafficController [nce.NceTrafficController Transmit thread]
2019-09-18 15:23:27,652 jmrix.AbstractMRTrafficController???? ERROR - Transmit thread terminated prematurely by: java.lang.NullPointerException [nce.NceTrafficController Transmit thread]
java.lang.NullPointerException
?at jmri.jmrix.AbstractMRTrafficController.getPortName(AbstractMRTrafficController.java:819)
?at jmri.jmrix.nce.NceConnectionStatus.nceEpromPoll(NceConnectionStatus.java:132)
?at jmri.jmrix.nce.NceTrafficController.pollMessage(NceTrafficController.java:430)
?at jmri.jmrix.AbstractMRTrafficController.transmitLoop(AbstractMRTrafficController.java:470)
?at jmri.jmrix.AbstractMRTrafficController$1.run(AbstractMRTrafficController.java:771)
?at java.lang.Thread.run(Unknown Source)

Any help is appreciated!
Jeff Mutter

?

Virus-free.

?


Locked Re: Edit of build report #operationspro

 

Is your Mac editor "TextEdit"? If so, try pressing Command F.


Locked Re: NCE PowerPro Connection Issues

 

Jeff,

One trick is to confirm if the serial out to the command station is working.
The trick is you need to look real close at the 9 pin connector and then
jumper pins 2 to 3. If you do this, then start JMRI. The message about
command 0xAA will change. Instead of timeout, it will complain it doesn't
make a proper response since the 0xAA is now looping back to itself. That
would prove all the way to the front of the command is working ok. Then I'd
say the other step to take (not likely to help) is to open the command
station and make sure the upper board is seating right onto the lower board.
Also inspect around the back side of the 9 pin connector incase you see
something like a broken solder joint. These haven't been the case many times
over the years, but it might have helped a couple of times.

-Ken Cameron, Member JMRI Dev Team
www.jmri.org
www.fingerlakeslivesteamers.org
www.cnymod.org
www.syracusemodelrr.org


Locked Re: NCE PowerPro Connection Issues

 

Jeff, I was going to direct email you, but realized that it's better having all these wonderful folks see my response - just in case I'm too far off base!? We discovered recently that there are some problems with some interfaces in 4.16, and it might be worth your while to try the most recent test release, 4.17.4.? If this isn't good advice, there will be helpful comments, and you should heed their advice - these guys are the greatest!
See you soon!
John Swanson


Locked Re: Edit of build report #operationspro

 

Is the editor the same one that you used previously?? Maybe something on your computer changed, so that you're using a different editor.??

Dan


Locked Re: Edit of build report #operationspro

Frank in Houston
 

Sorry...yes...I get the preview...then text editor...then I can scroll down the build report...but I cannot find the "FIND" option which normally appears at the top of the build report...THANK YOU...Frank in Houston


Locked Re: Edit of build report #operationspro

Frank in Houston
 

Hi Dan....Just to clarify....YES....It is the first line of the options and it is checked. ?I did not confuse it with the option to print the manifest in text editor format on the main settings page...

THANK YOU....Frank in Houston


Locked Re: Edit of build report #operationspro

 

I don't understand your answer. But if you have the "Use text editor to preview build reports" selected, that should bring up your computers text editor when previewing the build report for a train.? Are using using the "preview" for your build reports?

Dan


Locked Re: Edit of build report #operationspro

Frank in Houston
 

Hi Dan.....YES....It gives me the manifest but not the "FIND" in the build report....THANK YOU....Frank in Houston..


Locked Re: Edit of build report #operationspro

 

Frank,

In the Build Report Options window, do you have the option to use an editor selected?

Dan


Locked Signal Mast Appearance definition file

 

Hello. I am trying to learn how to set up Signal Mast logic. The JMRI documentation "JMRI: Signal Mast Logic" is pretty good but has me stumped when it talks about the?Signal Mast Appearance definition file. I've loaded a sample panel file (AFarfelu16Fadj1.xml) in order to learn something, but can't figure out where the?Signal Mast Appearance definition file would be for this. Nor do I know how to view r modify it. Thanks!


Locked Re: NCE PowerPro Connection Issues

 

Ok...I updated the driver for the adapter, but my computer didn't like that
and Device Manager kept refreshing about every 10 seconds or so. When I had
a bad adapter several years ago, it did the same thing, so I rolled back to
the previous driver and it's stable again.

Is there a way to check the command station to see if the RS232 port is
working properly? I'll call NCE in the morning, but if there's any easy way
I'd like to try tonight. Are there any other settings in the command
station I should check? I REALLY don't want to reset the CS to factory
settings, because I'll lose all my consists.

Thanks for your help!
-- Jeff

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Ken
Cameron
Sent: Wednesday, September 18, 2019 5:50 PM
To: [email protected]
Subject: Re: [jmriusers] NCE PowerPro Connection Issues

Jeff,

I'll let Dave speak about the different USB-serial devices. He has a
standard
page explaining some of the principle ones.

But looking at your log, it NEVER talks with the command station. It
tries,
but never gets an answer. As I said, it gives a green status at first
because
the test had not timed out yet. Maybe we should show it as yellow for
'unknown' and then green if we get a replay or red if we don't. But color
isn't real good for interfaces, some people don't see colors that well. So
at
first it could say 'testing' until it knows one way or the other. Minor
point,
generally people wait long enough to start that it doesn't matter.

-Ken Cameron, Member JMRI Dev Team