Locked
Re: Logix
Thank you to everyone that contributed to my problem.? I have at last a train that can go around a loop with Dispatcher and stop in the station and then continue after a time.? I have successfully
By
Graham Orriss <graham.orriss@...>
·
#149730
·
|
Locked
Re: Using a Large Number of Connections to JMRI
Large numbers of C/MRI connections via Ethernet should not be a problem. Each one will use less than a MB of additional RAM. The network stacks are pretty efficient of CPU time, and don¡¯t care about
By
Bob Jacobsen
·
#149729
·
|
Locked
Re: JMRI Throttle
Richard, Check the Edit->Preferences->Defaults, make sure the options selected LocoNet for all of them. -Ken Cameron, Member JMRI Dev Team www.jmri.org www.fingerlakeslivesteamers.org www.cnymod.com
By
Ken Cameron
·
#149728
·
|
Locked
JMRI Throttle
At our club we have a windows 7 32 bit computer loaded with Decoder Pro 4.12 with the latest JAVA for 32 bit. It is connected through USB com port 4 to a Digitrax DCS 240, Decoder Pro set as a PR3
By
fire5506
·
#149727
·
|
Locked
Re: Using a Large Number of Connections to JMRI
I'm thinking about using Arduino Mega modules. These have 54 I/O ports available at a lower cost than CMRI hardware and also can be programmed to implement logic locally. The Ethernet connection only
By
jerryk4884@...
·
#149726
·
|
Locked
Re: Using a Large Number of Connections to JMRI
Jerry, Why the high number of connections instead of being nodes on a bus? Given the usual cost of interfaces for the connections, it adds up kind of fast for most hardware. -Ken Cameron, Member JMRI
By
Ken Cameron
·
#149725
·
|
Locked
Re: Using a Large Number of Connections to JMRI
Jerry, Why multiple connections ? CMRI uses a piggyback connection for the RS232/485 communications buss. All you need is one comm port connection to accommodate any number of CMRI nodes. The system
By
Nick <cornwall9@...>
·
#149724
·
|
Locked
Using a Large Number of Connections to JMRI
Hi, I would like to know what the limitations are to using a large number of connections to JMRI. I'm looking at defining in the area of 10 CMRI connections using either USB or Ethernet to connect to
By
jerryk4884@...
·
#149723
·
|
Locked
HO/HOn3 vs OperationsPro
I have an HO/HOn3 layout and have successfully built trains for the narrow gauge portion of the layout. I¡¯m new to JMRI and do not have a strong computer background. I am now trying to integrate the
By
Phil Miller
·
#149722
·
|
Locked
Re: Newbie control panel file question
Don, Select Panels >> Save Panels... from the main PanelPro window. There are other locations but this one always works. Dave Sand
By
Dave Sand
·
#149721
·
|
Locked
Newbie control panel file question
Sorry to bother you about this, but here goes: I have an embarrassingly basic question, it's about control panel but probably applies to other JMRI functions as well... I attempted to create a control
By
Don Weigt
·
#149720
·
|
Locked
Re: Detection going crazy
Sounds like maybe your cab bus is underpowered? You mentioned adding boosters? But there is still only one command station and unless I¡¯m mistaken that is the only source of power unless there are
By
Mark Ziebell
·
#149719
·
|
Locked
Re: Decoder Pro returns 123 for all decoder settings
... and upgrade to 4.12 - what you're encountering is a typical 4.10 problem, and it will happen again (and again). Wouter
By
whmvd
·
#149718
·
|
Locked
Re: Decoder Pro returns 123 for all decoder settings
Bob, Make sure that LocoNet is selected in Preferences >> Defaults. Dave Sand
By
Dave Sand
·
#149717
·
|
Locked
Decoder Pro returns 123 for all decoder settings
OK, using DP V4.2 and LocoBuffer-USB and WIN10. Haven't used DP in several months. The last time I used it it was working properly. Today the problem is that when trying to read values from a decoder,
By
nebrzephyr
·
#149716
·
|
Locked
Re: Detection going crazy
Sorry one more thing. That is when we started adding the power boosters and the problem seemed to go away. That is until yesterday.
By
Albert Matzelle Jr
·
#149715
·
|
Locked
Re: Detection going crazy
Thanks folks ... i'll look into these suggestions and get back with results. FYI ... The throttle numbers are unique. That was double checked since we did experience that once several months ago
By
Albert Matzelle Jr
·
#149714
·
|
Locked
Re: Logix
What would you use to trigger the missing layout sensor(internal) to be active. Could you say when previous block is occupied to turn the internal sensor active after a delay guessing when the engine
By
AD
·
#149713
·
|
Locked
Re: Logix
Graham, It is possible to use Logix and internal sensors to simulate missing layout sensors. The biggest challenge is that you also have to simulate the direction of traffic so that the virtual
By
Dave Sand
·
#149712
·
|
Locked
Re: Logix
Thank you all for your replys.? Am I best to install more physical sensors, which will cost,? If I have a physical sensor on a block, turnout,? track with a block reference, turnout, track with a
By
Graham Orriss <graham.orriss@...>
·
#149711
·
|