Re: Norcold not cooling well on LP #Norcold


 

¿ªÔÆÌåÓý

Have you checked the air intake/exhaust lines for wasps/ spiders/ etc? Sounds like a lack of combustion air or back pressure on the exhaust side. Have you checked the thermostat? I am about to replace mine because I have been unable to control the temperature of my NOrcold. Are the fans working on the condenser side? sometimes the thermoswitch fails and the fans don't come on. You should be able to achieve ~ 50 deg F differential between ambient and fridge temp.


Sam

02 EVC

On 6/1/2021 7:55 PM, Darin Hornbaker wrote:

I just went through the same scenario where my Norcold won't cool the same on LP after cleaning and replacing the burner and igniter, so I'm also curious if anyone has any suggestions.

Cheers all,
Darin

1995 Camper 168k

On Tue, Jun 1, 2021 at 4:50 PM David Horner <dahorner@...> wrote:
My Norcold works well on AC, and for many years it worked extremely well on LP, too, even freezing items on the coldest setting of the dial.? Today I fired up the fridge on AC with the fridge dial turned to maximum cooling, and after 2.5 hours the temperature was down to 37 F.? At that point I switched over to LP.? After 3 hours on LP the temperature had risen to 42 F.? Outside temperature was 77-79 F.? One data point I don't have yet is how cold it can get on AC. ?

On a trip a few years ago I noticed that the fridge was not cooling well on LP and the burner exhaust was very dirty/oily.? You folks helped me diagnose the dirty exhaust problem, suggesting it was a bad burner.? I pulled the fridge and replaced the burner, and after that the LP burned clean.? But the fridge still didn't get as cold as it used to on LP.? So now I'm hoping someone can help diagnose that problem. ?