I just went through the same scenario where my Norcold won't cool the same on LP after cleaning and replacing the burner and igniter, so I'm also curious if anyone has any suggestions.
On Tue, Jun 1, 2021 at 4:50 PM David Horner <dahorner@...> wrote:
My Norcold works well on AC, and for many years it worked extremely well on LP, too, even freezing items on the coldest setting of the dial.? Today I fired up the fridge on AC with the fridge dial turned to maximum cooling, and after 2.5 hours the temperature was down to 37 F.? At that point I switched over to LP.? After 3 hours on LP the temperature had risen to 42 F.? Outside temperature was 77-79 F.? One data point I don't have yet is how cold it can get on AC. ?
On a trip a few years ago I noticed that the fridge was not cooling well on LP and the burner exhaust was very dirty/oily.? You folks helped me diagnose the dirty exhaust problem, suggesting it was a bad burner.? I pulled the fridge and replaced the burner, and after that the LP burned clean.? But the fridge still didn't get as cold as it used to on LP.? So now I'm hoping someone can help diagnose that problem. ?
David 2002 EVC
--
~~~~~ Big Shots 3201 Corte Malpaso, Unit 302 Camarillo, CA 93012 805-484-9111