CrestronConsole.Printline 2 #programming #simplsharp
I have a weird situation where one method in a simpl# module won¡¯t write to the console. for argument sake. Public string test() { CrestronConsole.PrintLine(¡°Hello World¡±); Return (¡°Success"); } I know that the method is being successfully called from simpl+ because it returns the string and that is seen by simpl+. But the Hello World doesn¡¯t show in toolbox. the strange thing is that every other method in the simpl# code will show message when printed to the console.
Started by gbnet.hifi@... @ · Most recent @
HR-310s battery corrosion 2
I am having a rash of HR-310s that the batteries are corroding within a very short time period, before the batteries die. This causes the remotes to not power up from batteries. Anyone else seeing this?
Started by Greg B @ · Most recent @
Intercom recommendations - Not 2N or Doorbird 6
Hi all. Just wondering if anyone knows of any IP intercoms/access control systems out there that might integrate well with Crestron? I currently use 2N IP Verso (gen1) and a couple of access control units (keypads) which do everything I want in terms of integrating with my Crestron but the thing that is killing me is the video quality of the door camera. Its horrible. Low res, grainy and unusable at night. I am also not a big fan of the 2N licensing structure and having to pay extra for this and extra for that and even just the subscription cost to have it call our phones. Ultimately I wanted 2N for the ability for the intercom to be used on our TSW panels but as it turns out, we just dont use that feature. When the doorbell rings, one of us has answered it on our phone before getting anywhere near a TSW! Im looking for something that can provide a higher quality image, with the ability to add access control units to the system, and there are a few options out there, but I need the ability to control the units IO ports via an API through Crestron at the same time. I use this for door locking/unlocking from Crestron and also door open/close monitoring among a few other things. Hikvision do a very similar system to the 2N which ticks all the boxes, but as far as I know, their API is non existent so I would lose Crestron control. Have also seen another brand called Akuvox which looks interesting and they seem to have control support for their devices, but I am just unfamiliar with the brand. I could always upgrade to the 2N IP Verso 2.0 but again, their prices are ridiculous and then add on the required automation licenses and ongoing subscription costs for each mobile device and it becomes a rather unattractive option. Any thoughts or recommendations? Or am I looking for a fairytale project that just doesnt exist in the price range of common folk?
Started by Bambam_101 @ · Most recent @
TCL display IP control 3
Does anyone have the specs on how to control a TCL display via IP? It's their new 115" display. I can turn it on via WOL, but I can't find anything else on it's IP control. I've spoken to their tech support, and tier two took all my contact information and I never heard back. All I need is power off and inputs. TIA
Started by Jim Germany @ · Most recent @
DM-NVX-360 - USB Routing (NUX) 8
Hello Crestron Family, I have an NVX system here where we are now trying to implement NUX (USB-Over-IP) as well. The layout looks a little something like this: IFP110 Viewsonic Smartboard USB-B -> USB-A DM-NVX-360 Decoder -> Aruba CX-6100 PoE switch -> DM-NVX-360 Encoder USB-C -> USB-A Client OFE Computer Basically we are trying to get a ViewSonic touch screen display to act as another mouse on the client's computer via NVX USB routing. I have the NVX routing working fine and I manually route USB via layer 2 transport mode, and both NVX-360's say "Paired" and act like the USB is connected and will work, but my touch screen is not controlling the computer on the far end at all. I get the same reslult with layer 3 transport mode as well. I have tried both the HOST port and HID port on the touch screens decoder, but I get the same result. "Paired" but doesn't control anything. Perhaps someone has done this before and can tell me what I am missing? Thanks in advance for any input. -- Stephen H Programmer / Installation Technician
Started by Stephen @ · Most recent @
LightShark module
Hi, Has anyone ever worked with LightShark lighting setup (LS-1 console and LS-Node-4 DMX/ethernet node). Are there any crestron modules for LightShark? I couldn¡¯t find any in the usual places. Thanks!
Started by Dominion @
Topics in Home Automation - New Article in Residential Tech Today 13
Smart motorized shades are a valuable addition to a smart home. However, a consumer has only had two choices when choosing shades: 1) Off-the-shelf shades that have limited options and typically won't fit your window. 2) Custom shades that include a wide range of fabric choices, are custom cut to exactly fit your window, and come with a premium price tag. SwitchBot's new Roller Shade bridges the gap between these 2 choices. While SwitchBot currently only offers their Roller Shade with a single fabric choice, the shade can be custom fit by the homeowner to exactly fit their window. My latest article looks at this new shade option for smart home owners in detail. You can find the article here: https://restechtoday.com/reviewing-the-switchbot-smart-roller-shades/ For those interested in earlier articles that I've written, you can find those here: https://restechtoday.com/author/jaybasen/ For these interested in even earlier content that I wrote, you can find it all here though older content has formatting issues due to a transfer from blogspot to wordpress. https://topicsinhomeautomation.wordpress.com/ Thanks
Started by jbasen @ · Most recent @
Sensibo and crestron stopped working 12
I am hoping that @jbasen will see this. I have been using your sensibo module for a few years and it has been working fantastically well. Today the module has started erroring. Seems to be an SSL issue. The error is: 00:20:29.047: [Console Data] : Sensibo_Air - Refresh - Error Sending Device Command: Crestron.SimplSharp.Net.Https.HttpsException: Peer certificate cannot be authenticated with given CA certificates 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.ProcessInternalError(HttpsClientResponse response) 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.d(HttpsClientRequest A_0, Boolean A_1) 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.TryDispatch(HttpsClientRequest aRequest) 00:20:29.047: [Console Data] : at Crestron.SimplSharp.Net.Https.HttpsClient.Dispatch(HttpsClientRequest aRequest) 00:20:29.047: [Console Data] : at Sensibo_Air_Integration.Sensibo_Air.Refresh() 00:20:29.047: [Console Data] : at Sensibo_Air_Integration.Sensibo_Air.Initialize(String Device_ID, String API_Key, Int16 Default_Target_Temperature, String Default_Temperature_Unit, Int16 Debug) 00:20:29.047: [Console Data] : at UserModule_SENSIBO_AIR_V1_6.UserModuleClass_SENSIBO_AIR_V1_6.INITIALIZE_OnPush_0(Object __EventInfo__) 00:20:29.047: [Console Data] : at Amib.Threading.Internal.WorkItem.o() 00:20:29.047: [Console Data] : at Amib.Threading.Internal.WorkItem.Execute() 00:20:29.047: [Console Data] : at Amib.Threading.SmartThreadPool.e(WorkItem A_0 Thanks
Started by gbnet.hifi@... @ · Most recent @
Alternativce SACN module 7
Hi, I?m using the ?SACN SenderDirectSockets¡± module from the SIMPL device database to control an Enttec Ethergate Artnet/SACN to DMX gateway. In general, it works. However, it seems as if the module sends out all 512 channels, even if I change only one of them. This is very unfortunate, as I?m using an Enttec S-Play mini to send out prerecorded scenes to my fixtures via the Ethergate in parallel to the Crestron processor. Is there any alternative to SACN module (Artnet would be OK as well) available that sends out only the values for the DMX channel that has actually changed? Thanks, Thorsten
Started by Thorsten K?hler @ · Most recent @
DSC Neo Pro
Has anyone tried to use the DSC Neo IP modules with DSC Neo Pro? Thanks
Started by MGmail @
Topics in Home Automation - New Article in Residential Tech Today
Aqara has just announced significant new support for the Matter Smart Home Standard. My latest article explores the details of this announcement. You can find the article here: https://restechtoday.com/aqara-announces-new-support-for-the-matter-smart-home-standard/ For those interested in earlier articles that I've written, you can find those here: https://restechtoday.com/author/jaybasen/ For these interested in even earlier content that I wrote, you can find it all here though older content has formatting issues due to a transfer from blogspot to wordpress. https://topicsinhomeautomation.wordpress.com/ Thanks
Started by jbasen @
TST-1080 (html5 Construct) Subpage and text punch-through 2
In VT-Pro, overlaying text or a subpage over a button enables you to interact with controls underneath. This no longer appears to be the case in Construct. I have two instances in this particular project: * I have a footer menu subpage with a clear background - I'm using a Div (border) to form a background image with a button acting as a tab to hide or show this menu |--tab--| |--------------| | menu | |--------------| The area each side of the tab is clear. One of the buttons in the menu slides up a wireless mic list from the bottom of the page (under the menu) and then appears on the main page. The bottom mic in the list cannot be controlled because the menu clear space sits over it. I can't change the UI as this is a pre-agreed UI based on an existing TSW VTP project and I'm not allowed to deviate. * I have a button in a widget list that has 3 text objects over it containing event information This takes the form of: number - event name - event time Placing the text straight on the button just looks like shit as the placement gets messed up with the List header and it's impossible to get the text to line up correctly. In VTP, this works perfectly, in Construct, it appears that you can't pass a press event through a text object. Anyone know if it's possible to enable press-through?
Started by Slip Cougan @ · Most recent @
TST-1080 image resource path 5
I did ask this on the Crestron Discussions forum, but it seems to take days to get a response there. So posting here in the hope that you guys can help out. On a TSW panel, I can send an image to the panel like this: \images\icon - camera 100px wht.png The actual location on the panel is in: /display/swf/images On a TST, sending \images\icon - camera 100px wht.png does not work. The location on the TST where this graphic is stored appears to be: /display/app/project/assets/img Attempting to send: \display\app\project\assets\img\icon - camera wht 100px.png Yields no image What is the correct path to retrieve an image from the TST? I've tried a few combo's but nothing seems to work.
Started by Slip Cougan @ · Most recent @
How to control DT8 driver in Crestron DIN-Dali2 16
Hello everyone, I want to control DT8 driver using DIN-Dali2 module. I have already controlled DT6 drivers. My issue is when I add DT8 driver, it takes one address. How I can control a CCT led strip using simpl program. Currently I have CP3 processor and up to date firmware and database. Needs help/guidance to configure DT8 drivers. Thanks in advance for support.
Started by ManjitSingh @ · Most recent @
question about using ODT censor to turn on/off TV
Hi all, For a newly installed Flex Teams room, the client wish to turn on / off the TVs (2 x LG) automatically based on occcupancy. aside form the MX70 kit, I'm using an RMC4 and CEN-ODT-POE. I basically have the ?Room_Occupied / Room_Vacant? going to ?Multiple One shot? then to ?Crestron Connected ?. A senior programmer suggested i insert a ?Toggle? between the ?One Shot? and ?Crestron Connected?. Any reasons/advantages doing it this way? Thanks,
Started by Anhtu Vu @
Taurus UCX Series Module or TCP/IP Control 3
Hi All, Has anyone controlled the Lightwave Taurus UCX series device from the Crestron processor? If anyone shares the module or direct commands, it would be very useful for me. Thanks Bharath B
Started by Bharath @ · Most recent @
Autonomic M5Pro Integration 6
Is anyone aware if these new autonomic media servers integrate as seamlessly as the old ones? Do we still access the web gui and enter IPID and processor information to connect and get online, then just use CRPC joins on media object? I do not see the specific device to add to my program, wondering if I can just add it as an MMS-5? Or do these not integrate the same way the E series did? Thanks in advance.
Started by Dillon Costanza @ · Most recent @
UMC Creation issue 2
I'm wondering if anyone has started to see this lately. It's been pinching me this week... When making or updating .UMCs I will often have version as the suffix. ex: Module v1.0.1 Historically when I SaveAs, the Windows SaveAs dialog has the .umc type already selected and everything is good, like for decades... This week I noticed that when I update/save a module ending in a dot-#, even though Windows dialog has the type, the module gets saved WITHOUT the .umc extension. It will be saved as file name - Module v1.0 (Not Module v1.0.1.umc) and of course has no file reference. This is an easy fix, except for the wasted time and process workflow, but just wondering if others have seem this. Not sure if this is SMW, Windows or general digital crap...but I've only just started seeing this. It could be my PC, Windows 11...
Started by ckangis @ · Most recent @
NAX/AES67 Streams disappearing from some NVX devices 3
We have over 60 NVX endpoints installed in a building and a few weeks ago the audio streams stopped working on the NVX-351 and NVX-360 units, but still work on the E20 units. Video streams still work on all the units, but the audio streams just disappear from the stream list in Q-SYS Designer (the cores do the audio routing and processing for the building). If we subscribe to video and audio on a decoder connected to a TV via HDMI there is video but no audio as well. A reboot brings the stream back for 3-5 minutes and then poof! Gone again. IGMP snooping is enabled on all the switches, as is QoS, and no changes were made recently on the network configuration or other devices, so we're all a little baffled.
Started by mikecm@... @ · Most recent @
CP3 FW 6
Hi All, I have not been updating CP4's to the latest FW versions as, though I don't use the HomeKit features, I have no confidence that there will be other issues related to the HK/OpenSSL that will bite me... Thus I've paused at the xxx_2.8003.00056.01.puf firmware for 4-series. Regarding 3-series (CP3 primarily) I have paused at the xxx_1.8001.0251.puf Firmware. The latest 3-series version is xxx_1.8001.0295.puf. release notes don't mention anything about the HK/OpenSSL issue so I'm assuming that this is not an issue with this platform. Can others chime in about your use/dis-use and experience with this FW version? TIA!
Started by ckangis @ · Most recent @