Re: RS-232 commands that only worked over an unconventional termination...
Wait - Sharp changed parts of their protocol?? Inconceivable! On Thu, Jul 29, 2021 at 6:30 PM Lincoln King-Cliby via <lincoln=[email protected]> wrote:
|
Re: Simpl compiled zipped file is missing sgd
Also seen this recently when getting files from our other programmer. He had to send me the SGDs manually. Why did they break this feature? Its getting ridiculous these days. I am on software and databases that are probably 5-6 months old because I am tired of things breaking.?
|
Re: NVX Switchingh in simpl
Hmm, well I now have it working on a 2-series........
I have written a quick and dirty module to collect the input stream locations from the E30's and route to the D30's on receipt of an analogue value. Seems to work fine. I found a document about using the XIO symbol video out analogue to switch values but it seems to also require entering the subscription streams into a section under an "XIO routing" tab on the decoder....I cant seem to find this on the D30 GUI running V6 firmware....I have setup subscriptions on the decoder under the "subscriptions" tab by entering them manually, but this doesnt seem to allow the Video_Out signal to select them. Sending the location string works fine though, so ill take that for now. Site is having a processor / TP / NAX upgrade once we have rewritten the program and GUI to suit. |
Re: NVX Switchingh in simpl
Single subnet flat network 192.168.1.0 (setup in my office and stand-alone from anything else). I should mention that the processor in use is a CP2E as this is what is currently installed on the site we will be implementing the NVX to.
Site does have VLANS configured but will cross that bridge when we move the hardware from the office to the site! |
Re: NVX Switchingh in simpl
pearce.bruce
toggle quoted message
Show quoted text
On 30 Jul 2021, at 11:45, nick_masterson_uk <nmasterson@...> wrote:
|
NVX Switchingh in simpl
Hi,
First NVX install, and having a struggle switching from the program. Following on from the advice previously given here, I have installed a Luxul POE switch and added my E30 and D30 units. I have successfully configured my subscriptions and can switch sources from the decoder web gui. What I am struggling to do is switch sources from my simpl program. My NVX training was quite some time ago (pre release of the 30 series) but IIRC it was possible to do basic analogue switching, the values equating to the stream subscription list position. Looking at the D30 symbol I am assuming that this is the "video_Out" signal on the XIO routing sub-symbol? if so changing values here does not implement switching!? Am I looking in the wrong place / using the wrong signal /missing additional logic here? Cant find an example program to confer with...im sure its something simple, can anyone point me in the right direction? |
Simpl compiled zipped file is missing sgd
I seems like the compiled zip file generated by simpl windows does not include the smart graphics definition anymore...?If I send the file to somebody, there will be a bunch of warnings popping up because the GUI extenders will be missing.
I miss the days when you could just send someone the compiled zip file knowing that it included everything necessary for a clean compile... now this does not seem to be the case anymore.
anybody else noticed this? ?
|
Re: RS-232 commands that only worked over an unconventional termination...
开云体育What pins were connected on each end? ? Was is really only the program that was changed, or was hardware changed as well? ? To answer some of your curiosity: ? As it happens, RS-232c voltage specifications are not always “strictly” adhered to by various manufacturers, on both the control side and the controlled side. ? For example, the “com” ports on a 2-series processor use the full voltage swing but the IR port when used for “one-way serial” does not.? This means that some devices that are very robust (forgiving) will work on either and some devices that are more picky will not.? ? An older processor like a CP2e or a QM-RMC can be handy to use in your situation as it can be connected in place of the TV to check baud rate and commands.? You can also put one between the processor and the TV, using 2 com ports and a program that just connects rx of one port to tx of the other and then you can monitor both commands and responses as they pass through. |
Epiphan Livescrypt Integration?
I've been told to integrate this into a Council Chambers build. No published API or control inputs. All documented control is either from the local web interface, Epiphan Cloud, or the touchscreen built into the unit. Boo.
Before I start doing it, has anyone had some success reverse engineering any IP control protocol from the unit? From a quick look it looks like it has a basic web api and uses websocket communications on the admin page. I'm looking to get control over starting/stopping transcription and getting the current transcription status. As a bonus I would also like to get the current transcription output stream URL so I can scrape that too and get the text output from the unit live to re-distribute to the Youtube stream for the Council Chamber so they have proper subtitles and not permanently baked in subtitles. -Scott |
Re: RS-232 commands that only worked over an unconventional termination...
It wasn't that. The code worked perfectly once I routed it through a room controller, rather than the oddly run COM port coming out of the processor.
I'm confident the Serial settings were set correctly as well. It is very mysterious. |
Re: RS-232 commands that only worked over an unconventional termination...
开云体育And how many spaces may need to be in there . . .? that’s why I only put the RSPW ? Their protocol designer is probably the same person that determines how much a traffic ticket costs in Ca.???? Spin the wheel, throw a dart.? Thank you, please drive through. ? From: <[email protected]> on behalf of "Lincoln King-Cliby via groups.io" <lincoln@...> ? Except for the versions that required RSPW?? 2\x0D and a few iterations 1 had to be used instead of 2 (instead of 2 being network + serial active, 2 seemed to be network only, 1 kept serial alive) ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D ? From: [email protected] [mailto:[email protected]] On Behalf Of eagrubbs via groups.io ? Haven't you guys heard of RSPW2? ?\x0D? |
Re: RS-232 commands that only worked over an unconventional termination...
开云体育Except for the versions that required RSPW?? 2\x0D and a few iterations 1 had to be used instead of 2 (instead of 2 being network + serial active, 2 seemed to be network only, 1 kept serial alive) ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D ? From: [email protected] [mailto:[email protected]]
On Behalf Of eagrubbs via groups.io
Sent: Thursday, July 29, 2021 6:02 PM To: [email protected] Subject: Re: [crestron] RS-232 commands that only worked over an unconventional termination... ? Haven't you guys heard of RSPW2? ?\x0D? |
Re: RS-232 commands that only worked over an unconventional termination...
开云体育RSPW . . . ? Sharp! that's your problem!!...HaHa!!? The old units that I dealt with had an issue where the serial port would turn off after the set was turned off, which would require IR to run it on...Beautiful!! |
Re: Resi NVX install - cost effective compatible 24 port switch
开云体育I have had excellent results for small systems using Snap AV Araknis 310 series switches.? You need to set up IGMP querying as it is not ready to rock out of the box.? They have a white paper on set-up for NVX.? You can also set them up with Snap’s OvrC application for remote management. ? ? |