Re: OMG SB 3.10.....

 

Am I mussing something somewhere? I have added the weather module into SB but I don't get any pages. I click on the info for the module and it states This module works in conjunction with the "Crestron Weather Touch Panel Interface." Where do I find this interface? I have looked all over the crestron site as well as re-built and added tp to the program with still no luck.

Thanks

Paul

--- In Crestron@..., "neil.dorin" <neildorin@...> wrote:

Crestron DB --> Manufacturer --> Crestron --> Software --> Crestron Weather

Also the same location as the new MyCrestron Dynamic DNS symbol.

Cheers,

-Neil

--- In Crestron@..., Simon Cope <sjcope@> wrote:

I tried looking at the weather module myself yesterday with the same aim,
but couldn't find it in SB - where should I be looking?

Ta,

Simon C

On 15 February 2011 18:00, neil.dorin <neildorin@> wrote:



Ok, so has anyone tried the new SB release since yesterday...

I just added the new Crestron Weather device to my AMP-AIP system at home
to test the intended functionality and translate it to a SIMPL system I'm
currently programming.

When I read the release notes, I was skeptical at best....

My average build time for my home system was about 12 minutes.

I just added another MLX-2 to the program as well as the weather module and
a few other small changes.

Interface build time - about the same
Program generation - 2:33!!!!!!!!!!!!!!!!
Compile time - about the same

On the Finish tab, there are not options to simply "update system" which
according to the release notes can update portions of the program without
rebuilding in it's entirety.

This is revolutionary.... all my complaining was worth it LOL!

Cheers,

-Neil





Re: Free Terminal Program - Update

 

Just grabbed the new EXE and the crashing seems to be fixed! Great job Rick!

Jeff

--- In Crestron@..., Eric Walters <sentry07@...> wrote:

I have a Belkin as well and I don't have any crashing issues. Have you guys
grabbed the latest .EXE from his site? That's the version that is working
for me.


Re: 8G crimp tool generic alternative

 

Answered my own question: fortunately their "zoomable photo" is enough to give the game away since the part numbers are clear to see...and it's really $287...

OP

--- In Crestron@..., "Oliver" <oliver@...> wrote:

Is there a "generic" alternative to the DM-8G-CRIMP crimp tool for 8G cable? Anyone bought one of these? Who really makes it, Palladin or one of those manufacturers? Would love their part number if possible.

Thanks in advance

OP


Re: Crestron Mobile Pro G - Designing in Landscape

 

I wish Crestron would come out with an update to designing for iPad in VTPROe... I feel like it's not even worth messing with until I can start my design in landscape mode. I don't really trust or want to get involved with CommandFusion, although I hear it works well.

To make me happy all they would need to do is let me chose to make pages in landscape, portrait, or both, and lock the orientation if I'm only using one of them.

--- In Crestron@..., "xsdesignstudios" <xsdesignstudios@...> wrote:

Thanks for the replies guys.

CommandFusion is not an option this late in the game. For one I am not going to mess with having an issue with more than 5 iPads at once. The job is not using 3 series processors so I cannot afford to waste days at a time figuring out in the end that it won't work and having to start from scratch.


8G crimp tool generic alternative

 

Is there a "generic" alternative to the DM-8G-CRIMP crimp tool for 8G cable? Anyone bought one of these? Who really makes it, Palladin or one of those manufacturers? Would love their part number if possible.

Thanks in advance

OP


Re: TV One Option connection

mjrtoo2000
 

My application is to cross scale between analog rgbhv and SDI inputs to analog rgbhv and SDI outputs. I pulled the products and hooked them up this morning (controlling via tcp/ip). The switching worked just fine, the S2 and C2 product switches automatically.

I'll post back about the quality when the project is complete.

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

I haven't worked with one yet, but have been seeing them pop in to consultant designed projects a lot. I think they are using it mostly to strip HDCP, scale, and output as Analog. I'd be interested in hearing about hands on experiences with them.

--- In Crestron@..., "mjrtoo2000" <mjrtoo@> wrote:

Has anyone worked with a TV One scaler (in this case a C2-2355a) connected via the option cable to an S2-105PCA? If so, can you confirm that if you set the output of the C2 to any RGB input 1) Does it automatically set the S2 to the input you select? 2) Does it automatically switch the C2 to the RGB input?

Just getting the framework together for a system and the protocol/documentation is confusing to me.

Thanks,

Matt


Android control from Crestron coming Q2

 

Finally:


Re: Licensing source code for multiple usages

christian_oates
 

This is incredibly helpful. Moving forward I'll be tying each program to a MAC address, and of course updating my contract. I also like the idea of a support/modification retainer, which I hadn't considered. I'll keep you posted with developments. Thanks everybody.

Christian

--- In Crestron@..., "Witmarquzot" <tdurrant420@...> wrote:

Well it is by definition work for hire.

I agree with mr mjrtoo2000, why is a huge reason. Are they upset about the work you did? Are they leaving you? Do they want a backup seeing as there has been a slew of companies closing their doors? How are you supposed to learn from an experience if you don't ever find out what you are doing wrong.
--- In Crestron@..., "mjrtoo2000" <mjrtoo@> wrote:

I agree, but sometimes I wonder if its worth worrying about, there are probably bigger money leaks in a business to worry about. I suppose it's a different story if you're a CAIP.

What bothers me is when a sales guy tells me a client is asking for their code and doesn't even ask why and expects me to just send it. We always do, but at least ask. If a client is asking for code to replicate a system with another vendor, maybe its better they're gone anyway.


--- In Crestron@..., "Steve Kaudle" <steve@> wrote:

My boiler plate reads:



"Upon completion of the Description of Services and receipt of full payment
on or prior to the invoice due date, upon request from the Client, (my
company) shall on at least one occasion provide to the Client all code [pre
and post compilation] necessary to operate the control system[s] included in
the Specification of the Project. . . . Any code (my company) distributes to
the Client is provided with a license to utilize said code as desired only
in the control system[s] included in the Specification of the Project. Any
use or application of the provided code in part or whole in control
system[s] not included in the Specification of the Project is prohibited.
Any distribution of the provided code in part or whole to parties not named
in this quotation is prohibited."



I would view the replication of the system as falling outside of the
license. Whether or not A) I'd ever find out and B) be in a position to
and/or want to do anything about it is another matter.



Some sort of 'replication fee' would seem appropriate.



_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of christian_oates
Sent: Friday, February 18, 2011 3:18 PM
To: Crestron@...
Subject: [Crestron] Licensing source code for multiple usages





Gentlemen

I recently began working with a commercial dealer programming small
conference rooms (Picture an MPS-M5, DVD, PC input, and display - very
small). They took my advice and used a cookie cutter approach for future
conference rooms.soon one room turned into sixteen, and it looks like there
may eventually end up being over a hundred implementations.

It has always been my policy (a policy held by many of you) that after final
payment, the code belongs to the dealer. I've just never had a dealer plan
to use one small piece of code in possibly hundreds of instances. I've sold
modules on a per use basis, but (alas) none have been so wildly successful
as to warrant a licensing policy. Thusly: Do any of you license on a per use
basis? One well worded sentence added to my contract could mean a ridiculous
difference in income from this dealer. That is, if I can get my head around
the ethical issues (if there are any).

Christian Oates
Interactive Media Systems
917-945-4703





[Non-text portions of this message have been removed]


Re: Crestron Mobile Pro G - Designing in Landscape

 

Thanks for the replies guys.

CommandFusion is not an option this late in the game. For one I am not going to mess with having an issue with more than 5 iPads at once. The job is not using 3 series processors so I cannot afford to waste days at a time figuring out in the end that it won't work and having to start from scratch.

Secondly, I know about anchors but all that gives me is the protrait size on a landscape page so I have unused space all over the place.

From what I am hearing it looks like I am boned and need to develop it in portrait and have excess space on the sides....


Re: Issue Touch Tone (DTMF) via control system

 

CEN-TIA?

--- In Crestron@..., "yellowfin684" <jaredhaleck@...> wrote:

Thanks for the input. I will look at both approaches. Chris, your approach is particularly intriguing. I'll probably tinker with that first.


Thanks again!!


--- In Crestron@..., Joseph Vossen <jkv@> wrote:

I couldn't find a commercial product, but the webatron is filled with circuits to build your own, here is one example: <>


On Feb 22, 2011, at 7:45 AM, yellowfin684 wrote:

Ive got a gate to control that has momentary contact closure inputs to both open and close the gate. But the phone system is tied to the gate and from the phone system, you have more control. By pressing the following buttons:

1 = open (closes after 30 sec)
2 = open for 30 min
3 = Close
4 = Open indefinitely until the user closes it from phone system

The gate seems to be sensing the touch tone from the phone system to determine its behavior. The problem is, if the gate is open indefinitely or for a 30 min stretch, my little momentary contact closure from the control system won't close the gate.

I am looking for a widget that can issue touch tones (at least buttons 1-4)


Re: First Alert Alarm

 

Wow how did I miss that, As soon as I can get the alarm company back out here I will give it a try Thanks

--- In Crestron@..., "weddellkw" <weddellkw@...> wrote:

Thats probably your problem, see this document (from Honeywell Tech):


Note the Figure.6 (for the Vista BP series) vs. Figure.7 (for the FBP series). I have had to fix this behind our own techs multiple times (I keep meaning to cut the important sections out of that PDF and put them into my own cheat-sheet to be included with the job-spec...since technicians don't like reading instructions apparently.)

-kw

--- In Crestron@..., "bolina_1999" <bolina_1999@> wrote:

The 4100SM is connected to a header on the alarm board not to a zone.

--- In Crestron@..., "weddellkw" <weddellkw@> wrote:

Do you have the 4100SM connected to zone 9 of the security panel?

--- In Crestron@..., "bolina_1999" <bolina_1999@> wrote:

Has anyone intigrated a FirstAlert FA-1670C
I currently am having trouble communicating with the alarm panel
The alarm company says it's a re-branded Vista 128bp
All the setup feilds seem to be the same in that alarm setup.
The interface module is a Honeywell 4100SM.
I can see data on the from_device$ in Debugger whenever I open or close a door, but I cannot get the alarm to respond to a Poll or get feedback out of the zone status module.
Thanks Jim A


Re: Free Terminal Program - Update

 

I have a Belkin as well and I don't have any crashing issues. Have you guys
grabbed the latest .EXE from his site? That's the version that is working
for me.

On Tue, Feb 22, 2011 at 8:56 AM, jbudz1977 <jbudz1977@...> wrote:

What type of USB to Serial adapter are you using? I have a Belkin and am
having the same problem. I bought a different one to try but forgot to
bring it to work today.

Can't wait for this glitch to get worked out, since the program is great
otherwise.

- Jeff

--- In Crestron@..., "erikm_101" <erikm101@...> wrote:

Hi Rick,

I just downloaded your HTWin yesterday, but cannot get it to work with a
serial connection. As soon as I set the type to serial and configure the
port and click OK/Apply, the app crashes.

An ideas what might be happening?

Windows 7 Enterprise, 32 bit.


erik



--- In Crestron@..., "rickmcneely" <rickmcneely@> wrote:

Hi folks,

I have upgraded my terminal software with some neat new features.

Network connections come with much better error reporting. When a
connection fails, it is much more likely to respond with a useful error
message.

You can now EASILY create 'remotes'. A remote is an on-screen
representation of a remote with up to fifty buttons, each with programmable
push/repeat/release/toggle events.

It's being hosted at www.rickmcneely.com. There are plenty of screen
shots. Take a look and let me know what you think.

Rick



------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links




Re: First Alert Alarm

 

Thats probably your problem, see this document (from Honeywell Tech):


Note the Figure.6 (for the Vista BP series) vs. Figure.7 (for the FBP series). I have had to fix this behind our own techs multiple times (I keep meaning to cut the important sections out of that PDF and put them into my own cheat-sheet to be included with the job-spec...since technicians don't like reading instructions apparently.)

-kw

--- In Crestron@..., "bolina_1999" <bolina_1999@...> wrote:

The 4100SM is connected to a header on the alarm board not to a zone.

--- In Crestron@..., "weddellkw" <weddellkw@> wrote:

Do you have the 4100SM connected to zone 9 of the security panel?

--- In Crestron@..., "bolina_1999" <bolina_1999@> wrote:

Has anyone intigrated a FirstAlert FA-1670C
I currently am having trouble communicating with the alarm panel
The alarm company says it's a re-branded Vista 128bp
All the setup feilds seem to be the same in that alarm setup.
The interface module is a Honeywell 4100SM.
I can see data on the from_device$ in Debugger whenever I open or close a door, but I cannot get the alarm to respond to a Poll or get feedback out of the zone status module.
Thanks Jim A


Re: Storing history of analog values

 

Way cool shift register Jeremy.

--- In Crestron@..., Jeremy Weatherford <xidus.net@...> wrote:

Quick and dirty SIMPL solution is to use an ABUF to make a sort of
delay line, and send a WPULSE (single logic wave pulse) to the enable
to shift everything by one:

Value -> Value1
Value1 -> Value2
Value2 -> Value3
Value3 -> Value4

etc. Value1 will be the most recent saved, Value4 will be the oldest.
Use an ARAM if it needs to survive program reboots.

On Tue, Feb 22, 2011 at 10:01 AM, merriweather.randolph
<merriweather.randolph@...> wrote:
I want to keep a history of 5 to 10 changes to a single analog value. Does anyone have a suggestion of how I might accomplish this?

mer



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links





--
Jeremy Weatherford


Re: iPad issues

 

A bad dynamic graphic serial path. I was doing a project with an Axis Video server. On one page of my iPad I used the internal IP address of the Axis and I was able to view the MJPEG stream. However on a second page I used the WAN address and port with a supposedly proper port forwarded router but the app crashed right away. It stayed open but no button presses worked. Had to close the app and relaunch and avoid that page.

I called TB with some general iPad questions at the time and mentioned this and the resident iPad guru acknowledged the behavior saying it was the bad dynamic graphic serial path. TMI? Anyway, HTH/

Evan

--- In Crestron@..., "jacobbalcit" <jacobtbal@...> wrote:

The actual VTPro-E file is about 23,600KB. There are dynamic graphics for weather icons (x4), shade animations (x2), and iPod album art (x2) but none of them are ever updated simultaneously. The button that always freezes the app up is the iPod button which is only tied to logic that shows the iPod subpage, routes audio, and shows a note if there is no device docked or the database is loading/failed etc. Nothin has been changed with this button since it previously worked for about 3 days. What should I look for graphic wise that would cause the app to lock up?

Thanks,
Jacob
--- In Crestron@..., "Tres" <tres@> wrote:

No to be sore, but it is either in your graphics or you are doing some funky
coding and killing the app with a bunch of updates at once.



I have yet to see the app lockup on its own since the latestes iteration of
the app and database.



Is your file really large? Are you sending dynamic graphics? Etc?



From: Crestron@... [mailto:Crestron@...] On Behalf
Of jacobbalcit
Sent: Friday, February 18, 2011 2:53 PM
To: Crestron@...
Subject: [Crestron] iPad issues





So this is the first iPad I've used and until today everything was going
great. I've been working with this control system for a couple days and
everything was fine. I was only making minor changes and little things that
were missed so nothing really changed. Now Mobile Pro G seems to keep
locking up.

Sometimes as soon as the flash page loads its already locked and nothing
happens. The time at the top of the screen doesnt change or anything. When
it doesnt lock up from the start, it always locks up when you press the 3rd
item on a list control from the main page. Once that is pressed it becomes
unresponsive, server one disconnects, than a minute or two later it connects
to server 2. The panel than flashes with the right sub pages and immedietly
goes to "Updating". You can see the updates sent from the processor in the
debugger and 2 seconds later server 2 disconnects...the panel gets stuck on
"Updating" and eventually connects to server 1 a few minutes later back and
forth until you quit the app and restart the program.

I tried deleting the list control and making a new one. It worked for a few
minutes after the new upload but now the same problem is occuring. Any help
would be appreciated! It's extremely frustrating because it was working fine
the last few days and now that I'm 99% done it's all going to hell.

Thanks,
Jacob





[Non-text portions of this message have been removed]


Re: First Alert Alarm

 

The 4100SM is connected to a header on the alarm board not to a zone.

--- In Crestron@..., "weddellkw" <weddellkw@...> wrote:

Do you have the 4100SM connected to zone 9 of the security panel?

--- In Crestron@..., "bolina_1999" <bolina_1999@> wrote:

Has anyone intigrated a FirstAlert FA-1670C
I currently am having trouble communicating with the alarm panel
The alarm company says it's a re-branded Vista 128bp
All the setup feilds seem to be the same in that alarm setup.
The interface module is a Honeywell 4100SM.
I can see data on the from_device$ in Debugger whenever I open or close a door, but I cannot get the alarm to respond to a Poll or get feedback out of the zone status module.
Thanks Jim A


Re: Issue Touch Tone (DTMF) via control system

yellowfin684
 

Thanks for the input. I will look at both approaches. Chris, your approach is particularly intriguing. I'll probably tinker with that first.


Thanks again!!

--- In Crestron@..., Joseph Vossen <jkv@...> wrote:

I couldn't find a commercial product, but the webatron is filled with circuits to build your own, here is one example: <>


On Feb 22, 2011, at 7:45 AM, yellowfin684 wrote:

Ive got a gate to control that has momentary contact closure inputs to both open and close the gate. But the phone system is tied to the gate and from the phone system, you have more control. By pressing the following buttons:

1 = open (closes after 30 sec)
2 = open for 30 min
3 = Close
4 = Open indefinitely until the user closes it from phone system

The gate seems to be sensing the touch tone from the phone system to determine its behavior. The problem is, if the gate is open indefinitely or for a 30 min stretch, my little momentary contact closure from the control system won't close the gate.

I am looking for a widget that can issue touch tones (at least buttons 1-4)


Re: TV One Option connection

 

I haven't worked with one yet, but have been seeing them pop in to consultant designed projects a lot. I think they are using it mostly to strip HDCP, scale, and output as Analog. I'd be interested in hearing about hands on experiences with them.

--- In Crestron@..., "mjrtoo2000" <mjrtoo@...> wrote:

Has anyone worked with a TV One scaler (in this case a C2-2355a) connected via the option cable to an S2-105PCA? If so, can you confirm that if you set the output of the C2 to any RGB input 1) Does it automatically set the S2 to the input you select? 2) Does it automatically switch the C2 to the RGB input?

Just getting the framework together for a system and the protocol/documentation is confusing to me.

Thanks,

Matt


Re: Storing history of analog values

 

Yeah, wishful thinking :(

--- In Crestron@..., "Kol Johnson" <kol.mstc@...> wrote:

?? What is this x++ dream?


_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of Brian
Sent: Tuesday, February 22, 2011 7:30 AM
To: Crestron@...
Subject: [Crestron] Re: Storing history of analog values




Analog_input analogVal;
Analog_output analogStored[maxNumToStore];
integer x;

change analogVal
{
if(x>=maxNumToStore)
x=1;
else
x++;
analogStored[x]=analogVal;

}

function main()
{
x=0;
}

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> ,
"merriweather.randolph" <merriweather.randolph@> wrote:

I want to keep a history of 5 to 10 changes to a single analog value. Does
anyone have a suggestion of how I might accomplish this?

mer






[Non-text portions of this message have been removed]


Re: First Alert Alarm

 

Do you have the 4100SM connected to zone 9 of the security panel?

--- In Crestron@..., "bolina_1999" <bolina_1999@...> wrote:

Has anyone intigrated a FirstAlert FA-1670C
I currently am having trouble communicating with the alarm panel
The alarm company says it's a re-branded Vista 128bp
All the setup feilds seem to be the same in that alarm setup.
The interface module is a Honeywell 4100SM.
I can see data on the from_device$ in Debugger whenever I open or close a door, but I cannot get the alarm to respond to a Poll or get feedback out of the zone status module.
Thanks Jim A