¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: CrestronGo Remote Access
As Lincoln mentioned, virtually all newer ISPs are using Carrier NAT for their IPv4 address and/or are using IPv6 addresses.? The main reason is probably because real IPv4 addresses are in short
By Steve Kuehn · #249667 ·
Re: DSC PowerSeries Neo
The Neo module is 4 series only, that may be your issue.
By Gary Miller · #249666 ·
Re: CrestronGo Remote Access
Try setting port 50443 as public and 443 as private port. It may work
By fabio.r.ribeiro@... · #249665 ·
Re: CrestronGo Remote Access
Your provider may not be giving you a true IPv4 WAN address but may be using CGNAT (¡°Carrier Grade¡±, i.e. ISP-level, network address translation) ¨C essentially putting your NAT router behind
By Lincoln King-Cliby · #249664 ·
Re: DSC PowerSeries Neo
I just downloaded the latest version, and loaded it into my processor. Unfortunately no matter how long I waited, it still could NOT connect! Any help from anyone would be much appreciated! p.s. I
By lo@... · #249663 ·
Re: CrestronGo Remote Access
I used a raspberry pinto create a vpn into house and installed on phone. ?If I need to use the app remotely I just connect to vpn first.
By cmac_HT · #249662 ·
Re: CrestronGo Remote Access
Just to add I had an odd message from my Fibre provider that port forwarding may not work as their service is IPv6 based?
By Adam · #249661 ·
CrestronGo Remote Access
I haven¡¯t tried this via cellular access since the previous apps butI cannot get it working. Ihave set up mycrestron and have added xxx.mycrestron.com as the domain using the text console. I have
By Adam · #249660 ·
DIN-CENCN-2-POE factory reset
Having a weird issue where one of two units is not getting an IP address/doesn¡¯t seem to be recognizing network changes (other unit works just fine). Have tried regular reset, power off, etc. Anyone
By Dmitri Mirovitski · #249659 ·
Re: DSC PowerSeries Neo
That's good news!! Just to confirm, are you working with SMW or Home?? I'm interested in SMW...
By ckangis · #249658 ·
Re: DSC PowerSeries Neo
DSC NEO module is working now , went back an forth with Crestron about issues and they made updates and last version is working.? The module takes 10 minutes or so before it actually connects.?
By Gregory Oldacre · #249657 ·
Re: Toolbox (Latest Version Bug)
https://www.crestron.com/Software-Firmware/Software/Crestron-Toolbox/Crestron-Toolbox/3-1230-0051-0 https://www.crestron.com/release_notes/toolbox_3_12_30.pdf Toolbox - Release 3.12.3 (Version
By Dave H - Crestron True Blue Tech Support Engineer Since 2014 · #249656 ·
Re: Logic Engine Error
Having a similar issue on firmware 2.8.000 . didn't start until i upgraded. what version is the processor on?
By Chris.estes@... · #249655 ·
Re: DSC PowerSeries Neo
Hey Tony, et.al. Anyone heard of any updates on this?? or more importantly, does it actually provide any function like a keypad emulation, zone status, etc. I have a client that needs a security
By ckangis · #249654 ·
Re: How to get C# trigger a method based on event from Simpl+
Ok thanks for confirming; I had incorrectly assumed it was because the class hadn't been newed up, but it must be (as you say) down to architecture/sequencing.
By @DizzyEgg · #249653 ·
Re: How to get C# trigger a method based on event from Simpl+
The constructor definitely gets fired well before the SIMPL side of things has fully fired off ¨C I¡¯ve seen constructor print messages inserted in the program header print during boot and before
By Lincoln King-Cliby · #249652 ·
Re: How to get C# trigger a method based on event from Simpl+
So if you put a 1 on a digial input or analog init and drive an input into a Simpl+ module that calls a C# method you don't get an exception? I get an exception every time, unless I allow a short
By @DizzyEgg · #249651 ·
Re: How to get C# trigger a method based on event from Simpl+
I¡¯m sorry to call you on this one, but it¡¯s simply wrong. Global S# objects are instantiated well before the SIMPL engine gets going. ?No exceptions. Put some Console prints in the object
By Oliver Hall · #249650 ·
Re: Stepper Bug?
+1 for what Lincoln said. Ran into this a few times where the transfer dialog is open but does not have focus. Sometimes it's under another window.
By Tray Schaeffer · #249649 ·
Re: How to get C# trigger a method based on event from Simpl+
Make sure you aren¡¯t triggering the Simpl+ input playerPress too early in your Simpl program. I assume you¡¯re setting _myGame along with the other global variables at the top of the file. If you
By @DizzyEgg · #249648 ·