¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Seura Shade 2 RS-232 control
FTR, we got things working with the strings as noted above. Seems to work great - 115k baud BTW...because we really need to turn it on quickly!...HaHa It still did take us 4 hours unrelated to the
By ckangis · #250405 ·
Re: Content Player
How you set up FB massage for Crestron in BS player? Is it send UDP "name of feedback" in advanced section of movie files?
Re: Epson Projector Crestron Connected
There is a third important setting when you want to control via lan hdbaset : in my memory it¡¯s (in French, sorry) : ? mode attente ? activated in ? R¨¦glage AV ? > ? sortie AV ? I don¡¯t
By Jehuty47 · #250403 ·
Re: Epson Projector Crestron Connected
There's 2 important settings in Epson projector menu: Signal I/O, A/V input to *ALWAYS ON* Signal I/O, HDBaseT communication to *ON*
By Alex_PFT · #250402 ·
Topics in Home Automation - New Article in Residential Tech Today
My latest article, "Managing a Home¡¯s Air Temperature Based on the PMV Comfort Model¡± is being published by the good folks at Residential Tech Today Magazine on their web site. Since the
By jbasen · #250401 ·
Re: Seura Shade 2 RS-232 control
Here's what we use: Power ON-- \x02PWD:1\x03 Power OFF-- \x02PWD:0\x03 Mute ON-- \x02MUT:1\x03 Mute OFF-- \x02MUT:0\x03 Input 1-- \x02INP:1\x03 Volume 50-- \x02VOL:050\x03
By Alex Teague · #250400 ·
Re: Seura Shade 2 RS-232 control
\x02PWD:0\x03
By plareeeiybusse · #250399 ·
Re: Cheap reliable power monitoring.....ya right.
Many of the current generator installs they have an on board or add-on I/O and Relay board that can be programmed for various faults/statuses (Kohler calles it a PIM for example). We always tie into
By @johnmax · #250398 ·
Re: Seura Shade 2 RS-232 control
Must admit, I love protocols that start and end with \x02 and \x03 :)
By Slip Cougan · #250397 ·
Re: Seura Shade 2 RS-232 control
That's what I thought but their docu was confusing to me, with their example string... Thanks Eric!!
By ckangis · #250396 ·
Re: Seura Shade 2 RS-232 control
For Crestron you would use \x** to send a hex character. So, you would use \x03 not [0x03]
Seura Shade 2 RS-232 control
Hi All, I'll be working on a project with rs-232 control of a Seura Shade 2 TV and have the protocol doc. it lists the following for the start and end characters: ? Start with 0x02 (hex) ? End
By ckangis · #250394 ·
Re: Bond Bridge
I have one controlling a few different brands of fans plus some RF shades in the house. Jay's module works well, but I also have an ISY-994 controlling the same fans with some pretty simple commands.
By Randy S · #250393 ·
Re: Cheap reliable power monitoring.....ya right.
We used to do this with our Generac and then Kohler. Just used a bunch of 120V DIN rail relays and then watched the inputs on the processor. Caleb Radecky | Manager, Online Products & Services
By Caleb Radecky · #250392 ·
Re: Cheap reliable power monitoring.....ya right.
Something like this would work into the GPIO of another device. https://www.juicegoose.com/images/pdfs/Datasheets/RT-REL_Data_Sheet_R1.pdf
By Rob · #250391 ·
Re: Cisco Widgets - OS10 vs OS11
Update...I received a Codec Plus with OS11 and was able to check this myself (previously was working with a tech in the field). What I found is that, unlike 0S10, with OS11 if you have a Cisco widget
By David Aiello · #250390 ·
Re: Bond Bridge
I don't personally use the Bond bridge or Bond bridge pro in my own home.? However, I did write a Crestron driver for integrating them with a Crestron system including the use of Bond Sidekick
By jbasen · #250389 ·
Re: Bond Bridge
The Bond Bridge Pro is incredibly reliable and has a great range. I've had the same issues and I'll always install a Bond Pro. I'm in a high-density area in downtown Chicago for the most part and I
By FTAV · #250388 ·
Re: Bond Bridge
In a related subject, Does anyone have an experience about the performance difference with Somfy Shades, between the Bond Bridge and the LinkPro Z gateways regarding range and control reliability?? I
By ckangis · #250387 ·
Re: Cheap reliable power monitoring.....ya right.
I had to do something similar for a customer that found, during a power outage, that their generator had died and hadn¡¯t been performing its weekly load test. We just wired the coil of a relay to
By jbasen · #250386 ·