¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Sonos control is still working?
Okay now this is getting even more odd. I love the autonomics, even more than sonos. If I had my way, I would put an autonomics in every job. Okay, okay... We have had our share of failed soundcards.
Re: Sensibo x Crestron Home
I¡¯m having exactly the same issue. It¡¯d be great if the guys at LLC could chime in and hopefully steer us in the right direction to solve this issue thanks a lot in advance
By fvalenzi@... · #253435 ·
Re: Marantz Cinema 70s IP Control?
Brilliant, thank you Tony. [email protected]> wrote:
By Jeremy Weatherford · #253434 ·
Re: Marantz Cinema 70s IP Control?
I just uploaded "Marantz_FY21_SR8015_SR7015_PROTOCOL_V01.xls" to the group's Files area, although there was already a slightly older doc there. They're probably the same. I've done a couple systems
By Tony Golden · #253433 ·
Re: Marantz Cinema 70s IP Control?
Denon/marantz avr family works well NFH
By nicofreda · #253432 ·
Re: Marantz Cinema 70s IP Control?
I'm not super familiar with Marantz gear - what protocol specifically should I be looking for? Thanks.
By Jeremy Weatherford · #253431 ·
Re: Sonos control is still working?
RIP out Sonos and put in Autonomics? Wow, talk about out of the frying pan and in to the fire.
By rickwookie · #253430 ·
Rollease driver not loading after processor reboot #crestronhome #cp4r
After processor reboot, control of shades is lost. The Rollease Hub 2 still shows online but all shades associated report "Driver failed to load". Each shade then has to be reassigned to the room and
By stevenfink1967@... · #253429 ·
Re: Sonos control is still working?
@Steve Kuehn that is an interesting point about WiFi on Sonos. I will test this theory soon after we rip out Sonos and put in Autonomics, maybe that was an issue all along.
By Crestron_Programmer · #253428 ·
Re: Is matt_rasmussen_2000 still around here? Roku module help needed
Ah I dont think I ever noticed him posting there. I'll message him there. Thanks!
By @johnmax · #253427 ·
DMPS-300-C telnet control video board
is it possible to control dmps-300-c video board from telnet? trying to set : C2I-DMPS-300-VIDEO>setvideoroute 02 17 and nothing happens
By uoi.conf.center@... · #253426 ·
Re: Is matt_rasmussen_2000 still around here? Roku module help needed
He seems active and helpful to others on Facebook (Crestron Professional Group) I saw a reply from him 3 hours ago there is that helps
By RK-X · #253425 ·
Crestron Home - DM Transmitters
Hi All, Anyone have any issues with Crestron Home and DM Transmitters not appearing in the Pair Devices Folder? ?The DM-MD-16x16-CPU3 recognizes everything (all input, output cards, room boxes and
By giblp44 · #253424 ·
Re: Program load to processor - best practice
Thank you guys for the good information. I do agree that the 2 series processors are rather outdated and somewhat finicky at best. While it would be nice to be able to upgrade to a current processor,
By Don Schryver · #253423 ·
Re: Sonos control is still working?
Yeah, this has actually been a problem in the last ~6 months. I hadn't seen it before but they just keep coming up with new issues...:( I just logged into a site yesterday and had to manually restart
By ckangis · #253422 ·
Re: HZ2 for 5 or 6way Lighting Load Circuit
I see what you did there, Brian!! Good One!!!...:) I agree with Brian about this. I pretty much never use slave/remote devices for 3/4-way circuits, because you always seem to need a 'keypad' where
By ckangis · #253421 ·
Re: Sonos control is still working?
Just curious if anyone is using the "offline" output on the Sonos Device module.? I haven't seen a case yet when a Sonos end point gets dropped and the "offline" output doesn't go high.? I would
By Steve Kuehn · #253420 ·
Re: Sonos control is still working?
About 50% of my systems are like that... The other 50% are a problem... Haven't found anything unique about them...3 and 4-series, various FW versions, various vintages, various network hardware,
By ckangis · #253419 ·
Re: HZ2 for 5 or 6way Lighting Load Circuit
Hi Brian! Thanks for the reply. ?So, which of the Apex/Aux/SWEX ?are best for my use case? ?In fact, thinking about it. ?Is there any reason, save the Crestron system going down, to use the
By @FURY1996 · #253418 ·
Re: HZ2 for 5 or 6way Lighting Load Circuit
You can add as many KPEX devices as you want and just make them "programmatically" control the load. Just connect them to hot power only and ignore the traveler. We do this quite often with the Cameo
By Brian Matson · #253417 ·