Roku, preferred IP module
Didn't want to high jack the other the Roku problems thread.? I have the latest database but not seeing anything.? Have found a couple that rolled their own.
By
stefuel2
·
#255507
·
|
Re: RMC4 & ch5 web XPanel
Under "Project Format", select "Archived File" (vs) "Folder". The "Load Project As" radio buttons will no longer be greyed out.
By
David Aiello
·
#255506
·
|
Re: New Roku Issues
I can confirm Steve's reporting of issue number one as I have clients calling. :-(? Some more detail: -This seems to have been enabled between Roku v14.0 and v14.1, My testing was done on an Ultra
By
Jim Felderman
·
#255505
·
|
Re: any working NTP servers
Pretty sure Crestron processors only allow for time zone adjustment, as far as I¡¯m aware there¡¯s no DST offset in the web interface. I have a site that relies heavily on schedules so I¡¯m keen to
By
Tim Greenbank
·
#255504
·
|
Re: any working NTP servers
NTP servers provide UTC. Clients need to apply their timezone and daylight-saving offset. That's a general statement - haven't looked into how Crestron handle it, but the NTP side of things should
By
Paul Dengate
·
#255503
·
|
Re: any working NTP servers
Side question¡ do NTP servers adjust for daylight savings? Tim Greenbank Control Systems Engineer
By
Tim Greenbank
·
#255502
·
|
Re: any working NTP servers
It was a 2 series processor that I ended up just upgrading to a 4 series to use the internal NTP.
By
Brad Wykoff
·
#255501
·
|
Re: any working NTP servers
Are you on an older 2-series processor? All of the newer ones (3 and 4 series) don't need a module for NTP, you set the time zone/NTP in the Processor itself. I generally use a local one or googles
By
Chris
·
#255500
·
|
Re: any working NTP servers
I was using the Crestron module "Network Time Sync v1.0" with the default servers and getting errors in text console with debugging enabled.
By
Brad Wykoff
·
#255499
·
|
Re: any working NTP servers
The first two of those should be working; also time.windows.com has been an option in the past. NTP is on Port 123 and is not in any way like HTTP so if you're literally using
By
Lincoln King-Cliby
·
#255498
·
|
Re: Crestron CP4 and Lutron Athena through RS-232
Thanks for the follow-up.
By
Tony Golden
·
#255497
·
|
Re: Crestron CP4 and Lutron Athena through RS-232
Hello Group, To close this topic?: Phantom keypad could be under control if they are ¡°linked to the QSE-CI-NWK-E interface¡±, this is not by default and needs to be done by the Lutron programmer.
By
Antoine Dervin
·
#255496
·
|
Re: Recommandation for better organise Press/Visibility Digital join
Definitely don't use automatic assignment. Organize your joins in logical groups and start each group at a nice round number with some space for expansion. Don't be afraid to leave stretches of unused
By
Jeremy Weatherford
·
#255495
·
|
any working NTP servers
Anyone have a working NTP server? I've used "us.pool.ntp.org", "time.nist.gov" and "http://worldtimeapi.org/api/timezone/EST" and each are timing out, no response, or too many request.
By
Brad Wykoff
·
#255494
·
|
TSW-x70 button press responsiveness
Hi All, One of my pet-peeves of the digital age (yes, there are many!) is how I see buttons on digital devices, like my iPhone, register presses indicated visually by inactive-active-inactive FB but
By
ckangis
·
#255493
·
|
Re: RMC4 & ch5 web XPanel
These options are available on my RMC3
By
Slip Cougan
·
#255492
·
|
RMC4 & ch5 web XPanel
I'm trying to upload an html5 web XPanel to a new RMC4 on latest FW. The 'Load Project As' radio buttons are greyed out and it's default is CH5 mobile. Why is CH5 XPanel not selectable?
By
Slip Cougan
·
#255491
·
|
Re: BSS Gain Timed Block Control
I haven't ever controlled a Gain Timed block, and I don't think there's a ready-made module in the v1.4 (or any other version for that matter) that you can use; what I *do* know is you can definitely
By
igor.pero.bauer@...
·
#255490
·
|
BSS Gain Timed Block Control
Hello All, Have a very quick turn around project controlling a BSS Blu-100 for the first time in a while. I have all the DSP programmed, but wondering how to control the fade buttons in a Gain Timed
By
sbarnesvta@...
·
#255489
·
|
Re: New Roku Issues
Thanks Eric.? Unfortunately the Ethernet switch I am using does not allow me to block Multicast traffic on specific ports.? Putting the two Roku's pulling Multicast streams from the NAX on a
By
Steve Kuehn
·
#255487
·
|