Re: Sony VPL-FHZ50
Am in web page to see if ADCP is turned on. Of course, it prompts for a password. Cannot find the default PW anywhere. Anyone here know how to do this. Already did a factory reset so it should be the
By Tray Schaeffer · #250566 ·
Sony VPL-FHZ50
Trying to control this projector from a Crestron HD-RX system. Wiring and baud rate seem good because when I send this: power \x22on\x22\x0D\x0A I get this in reply: err_cmd\x0D\x0A Any ideas? Do not
By Tray Schaeffer · #250565 ·
Re: Evertz NUC=AV-100 session manager
Thanks for the comments and information in this thread. Without getting into NDA territory, is this a REST API device, simple TELNET, SSH? JSON required? CLI? POST-GET formatting? Having access to the
By BruteForceIsUnderRated · #250564 ·
Re: Scaling to 2.35:1
Hi, if you don?t want to just to cut off content, then you need a videoprocessor capable of scaling every content into your 2.35:1 AR. The one videoprocessors capable of doing so is the Lumagen you
By Thorsten K?hler · #250563 ·
Re: Override IP Table warning
How do you have your SIMPL TSW hardware definition IP Net address settings configured? If you don't have a "Default Address" defined (goes for any IP device) in the HW definition settings an IP table
By Alex Teague · #250562 ·
Re: Override IP Table warning
When it comes to IP Table entries, most Ethernet devices are written to the .dip file (found inside the .lpz). However, some newer devices (CEN-GWEXER, CEN-IO-XXXX, etc.) use a different mechanism to
By Dave H - Crestron True Blue Tech Support Engineer Since 2014 · #250561 ·
Re: Scaling to 2.35:1
Zoom would 'throw away' a third of the content, which may/may not be preferable. I would contact AV Pro Edge. They *May* have a box that does it... FTR, I don't think that DM or NVX have this feature
By ckangis · #250560 ·
Re: Shared GWEXER
Agreed with JohnMax.? It's the old adage "Just 'cause you can...doesn't mean you should!"...:) Also, you want to/have to manage the *RF-IDs* so that you don't have duplicate device IDs...It's obvious
By ckangis · #250559 ·
Re: Scaling to 2.35:1
A simple solution would be to simply have the projector zoom and use its masking feature to crop out any over-spill. With the quality of today's projector crop, this throws a pretty good image even by
By waffles · #250558 ·
Re: Shared GWEXER
It should only be done as Ckangis stated. You cannot use the same IP ID on two program slots of a processor. If you were sharing the gateway between two processors though, you could use the same ID in
By @johnmax · #250557 ·
Re: Crestron Mobile Pro G glitch
Thank you so much! That was the problem.
By Nightcountry · #250556 ·
Re: Evertz NUC=AV-100 session manager
The biggest problem with Evertz is how unhelpful they are if you have any questions.... Had one of their MMA-10G products and I was trying to wrap my head around theory of operations, capabilities,
By Lincoln King-Cliby · #250555 ·
Scaling to 2.35:1
Hey everyone, ?I inherited a decent sized retail job and the previous contractor installed a fairly large fixed 2.35:1 ish screen on the wall. ?The projector is a fairly new JVC 8k of some sort.
By AVMaster · #250554 ·
Re: Crestron Mobile Pro G glitch
Did you verify that Lock Configuration wasn't turned on?
By Eric Luckart · #250553 ·
Re: Override IP Table warning
I have only noticed this on a few projects. No rhyme or reason to it.
By Eric Luckart · #250552 ·
Re: Override IP Table warning
Sometimes when a program is recompiled the IP table entries are in a different order. This will cause the warning. I have discussed this with TB but only in passing. I first noticed it with an NVX
By metalmok · #250551 ·
Re: Evertz NUC=AV-100 session manager
I can answer general questions but I can't send code samples because the protocol is released to my company under NDA. That said, the coding was not difficult at all once the hardware is setup
By Tray Schaeffer · #250550 ·
Re: Evertz NUC=AV-100 session manager
I'm looking at some drawings for a system that uses this Evertz product and I need to price out time for it. Does anyone have some code examples that they are willing to share? I'm currently trying to
By BruteForceIsUnderRated · #250549 ·
Re: DIN-8SW8-I disable physical buttons
i found; " Hold SETUP button for 5 seconds to enable/disable" but... anyone know the textconsole command?
By Slavko · #250548 ·
Re: Crestron Mobile Pro G glitch
I think that there might be an issue with ProG deprecation and newer iOS software...I can't remember the details but others probably will weigh in...
By ckangis · #250547 ·