D3 Multiple loads grouped as one
Is there a way to group lighting loads so that D3 shows a single group vs individual loads? Essentially hiding the individual loads and only showing the group for adding to scenes and button presses?
By
John Gabler
·
#249192
·
|
Re: Custom Edid file?
The barco is just the conferencing system running on multiple Intel nucs. (barco nodes) All linked to one another via network.? Nucs all use a Linux back end with the Barco software up front. You use
By
Bambam_101
·
#249191
·
|
Re: Need help controlling old Somfy shades via IR
Steve, Thank you for following up and supplying the documentation you have. Somfy did respond to me and they also said the high voltage relay interfaces are ESI RP60AU devices.? Based on the
By
onetruezman
·
#249190
·
|
Re: Custom Edid file?
What kind of a display technology does this Barco system use?
By
ckangis
·
#249189
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
I'm currenty working with tech support on the rest API. So far they are not able to switch inputs.
By
Seadrunk69
·
#249188
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
The 4kz api is here: https://sdkcon78221.crestron.com/sdk/HD-MDNXM-4KZ-E_REST_API/Content/Topics/Home.htm
By
Kris K
·
#249187
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
Are you working with a 4KZ switcher or a 4k? On the 4kz, the top has been shutdown by the engineers because of security flaws. The "conf output 1 route 1" command works on the 4k but not 4kz. Extron
By
Seadrunk69
·
#249186
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
Wait so you have the protocol to control that switcher without needing a Crestron controller? Would you mind sharing? Cheers Natalie
By
Natalie Jackman
·
#249185
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
if you have the unit, test with with Putty from you laptop. the unit i have works on TCP port 23.
By
fujiakai@...
·
#249184
·
|
Re: LCD Toshiba
Hi Juan, that is strange. I found a driver in the Crestron application market (for the whole TD-E series), dated back to 2016. This driver as well states that the communication settings have to be set
By
crestronfreak55
·
#249183
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
I wish I had a Crestron processor. I'm using extron processor. :(
By
Seadrunk69
·
#249182
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
You add the device to the system configuration in SIMPL windows. Set the ip address for the device in the device settings. Then you load the program to your processor. The device will not register in
By
Natalie Jackman
·
#249181
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
Will it work with UDP? The engineers at Crestron locked tcp port in the 4kz series of switchers.? ?That's what Crestron is telling me.
By
Seadrunk69
·
#249180
·
|
Re: LCD Toshiba
I don?t see any of that in the menu of LCD Toshiba
By
Juan Lopez
·
#249179
·
|
Re: D3Pro with Cameo Keypads 6Btn Issue
#d3pro
#cameo
So for the CBD keypads that have the 'Lutron button 6 tax' applied, even though the image will force/show the split button 6 only, you can still program button 6 as normal and your 6-btn/non-split
By
ckangis
·
#249178
·
|
Re: Custom Edid file?
That is interesting. You can try using Extron EDID Manager to create an EDID file or modify an existing one. There are lots of options, either get someone that is familiar with EDID or use the try and
By
crestronfreak55
·
#249177
·
|
Re: LCD Toshiba
Hi Juan, did you enable RS232 in the Menu, Setup, Control and set the proper baudrate? Afaik, the Toshiba uses Pin 5 for GND, Pin 3 to receive the commands. Best regards Crestronfreak55
By
crestronfreak55
·
#249176
·
|
Re: LCD Toshiba
Yes, but not work
By
Juan Lopez
·
#249175
·
|
Re: LCD Toshiba
Those are, I suspect, Hex values, not ASCII values. Have you tried, for instance, \xBE\xEF\x03\x06\x00\x19\xD3\x02\x00\x00\x60\x02\x00 in an SIO?
By
Phil Bridges
·
#249174
·
|
Re: Custom Edid file?
Hi CrestronFreak. The Samsung has the ability to rotate the image and stretch if required so sending it a res of 1080*1920 does work, ie, a signal from my laptop running that resolution, but I just
By
Bambam_101
·
#249173
·
|