Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
Are you working with a 4KZ switcher or a 4k? On the 4kz, the top has been shutdown by the engineers because of security flaws. The "conf output 1 route 1" command works on the 4k but not 4kz. Extron
By Seadrunk69 · #249186 ·
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
Wait so you have the protocol to control that switcher without needing a Crestron controller? Would you mind sharing? Cheers Natalie
By Natalie Jackman · #249185 ·
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
if you have the unit, test with with Putty from you laptop. the unit i have works on TCP port 23.
By fujiakai@... · #249184 ·
Re: LCD Toshiba
Hi Juan, that is strange. I found a driver in the Crestron application market (for the whole TD-E series), dated back to 2016. This driver as well states that the communication settings have to be set
By crestronfreak55 · #249183 ·
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
I wish I had a Crestron processor. I'm using extron processor. :(
By Seadrunk69 · #249182 ·
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
You add the device to the system configuration in SIMPL windows. Set the ip address for the device in the device settings. Then you load the program to your processor. The device will not register in
By Natalie Jackman · #249181 ·
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
Will it work with UDP? The engineers at Crestron locked tcp port in the 4kz series of switchers.? ?That's what Crestron is telling me.
By Seadrunk69 · #249180 ·
Re: LCD Toshiba
I don?t see any of that in the menu of LCD Toshiba
By Juan Lopez · #249179 ·
Re: D3Pro with Cameo Keypads 6Btn Issue #d3pro #cameo
So for the CBD keypads that have the 'Lutron button 6 tax' applied, even though the image will force/show the split button 6 only, you can still program button 6 as normal and your 6-btn/non-split
By ckangis · #249178 ·
Re: Custom Edid file?
That is interesting. You can try using Extron EDID Manager to create an EDID file or modify an existing one. There are lots of options, either get someone that is familiar with EDID or use the try and
By crestronfreak55 · #249177 ·
Re: LCD Toshiba
Hi Juan, did you enable RS232 in the Menu, Setup, Control and set the proper baudrate? Afaik, the Toshiba uses Pin 5 for GND, Pin 3 to receive the commands. Best regards Crestronfreak55
By crestronfreak55 · #249176 ·
Re: LCD Toshiba
Yes, but not work
By Juan Lopez · #249175 ·
Re: LCD Toshiba
Those are, I suspect, Hex values, not ASCII values. Have you tried, for instance, \xBE\xEF\x03\x06\x00\x19\xD3\x02\x00\x00\x60\x02\x00 in an SIO?
By Phil Bridges · #249174 ·
Re: Custom Edid file?
Hi CrestronFreak. The Samsung has the ability to rotate the image and stretch if required so sending it a res of 1080*1920 does work, ie, a signal from my laptop running that resolution, but I just
By Bambam_101 · #249173 ·
Re: Custom Edid file?
Hi Bambam_101, using a display in portrait mode is not a matter of EDID. The video signal is still 1920x1080 and the display shows this as received. The orientation cannot be configured in the EDID.
By crestronfreak55 · #249172 ·
Re: LCD Toshiba
Hi Im try to send rs232 commands type ON BE EF 03 06 00 19 D3 02 00 00 60 02 00 OFF BE EF 03 06 00 19 D3 02 00 00 60 01 00 GET BE EF 03 06 00 19 D8 03 00 00 60 07 00 Also by CEC, now i want to copy
By Juan Lopez · #249171 ·
Custom Edid file?
Hi all. Currently doing my first Barco We Connect system and we have a Barco node (Intel nuc) that is connected to a Samsung lcd screen in portrait mode.? Problem is, there is no way to set the
By Bambam_101 · #249170 ·
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
there is a previous thread on thsi need add "conf" in front ex: conf output 1 route 1
By fujiakai@... · #249169 ·
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
you can TCP to the unit on port 23. I am using a hd-md4x1-4k-e. The syntax will be input <n> syncdetect <true/false> frontpanel lock <true/false> output <n> route input <n> name output <n> name input
By fujiakai@... · #249168 ·
Re: D3Pro with Cameo Keypads 6Btn Issue #d3pro #cameo
Just trying to put back the original program like it was before.? Old Cameo for Old Cameo and New Cameo for New Cameo.? ?All 6Btns & 3Btns.? I looked on some old hard drives from jobs back in 2009