Re: LCD Toshiba
Those are, I suspect, Hex values, not ASCII values. Have you tried, for instance, \xBE\xEF\x03\x06\x00\x19\xD3\x02\x00\x00\x60\x02\x00 in an SIO?
By
Phil Bridges
·
#249174
·
|
Re: Custom Edid file?
Hi CrestronFreak. The Samsung has the ability to rotate the image and stretch if required so sending it a res of 1080*1920 does work, ie, a signal from my laptop running that resolution, but I just
By
Bambam_101
·
#249173
·
|
Re: Custom Edid file?
Hi Bambam_101, using a display in portrait mode is not a matter of EDID. The video signal is still 1920x1080 and the display shows this as received. The orientation cannot be configured in the EDID.
By
crestronfreak55
·
#249172
·
|
Re: LCD Toshiba
Hi Im try to send rs232 commands type ON BE EF 03 06 00 19 D3 02 00 00 60 02 00 OFF BE EF 03 06 00 19 D3 02 00 00 60 01 00 GET BE EF 03 06 00 19 D8 03 00 00 60 07 00 Also by CEC, now i want to copy
By
Juan Lopez
·
#249171
·
|
Custom Edid file?
Hi all. Currently doing my first Barco We Connect system and we have a Barco node (Intel nuc) that is connected to a Samsung lcd screen in portrait mode.? Problem is, there is no way to set the
By
Bambam_101
·
#249170
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
there is a previous thread on thsi need add "conf" in front ex: conf output 1 route 1
By
fujiakai@...
·
#249169
·
|
Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
you can TCP to the unit on port 23. I am using a hd-md4x1-4k-e. The syntax will be input <n> syncdetect <true/false> frontpanel lock <true/false> output <n> route input <n> name output <n> name input
By
fujiakai@...
·
#249168
·
|
Re: D3Pro with Cameo Keypads 6Btn Issue
#d3pro
#cameo
Just trying to put back the original program like it was before.? Old Cameo for Old Cameo and New Cameo for New Cameo.? ?All 6Btns & 3Btns.? I looked on some old hard drives from jobs back in 2009
By
james@...
·
#249167
·
|
Re: VC-4 retrieving LPZ
#vc4
Assuming you didn't change the default install path, /opt/crestron/virtualcontrol/ProgramLibrary/X/App, where X is the program number (sequential from 1 since you started uploading programs).
By
jonathand@...
·
#249166
·
|
Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP
Hello Programmers, Due to supply issues with the MPC3-302, our client forced us to come up with another solution.? My boss was told from a crestron rep, that extron can control the crestron switcher
By
Seadrunk69
·
#249165
·
|
Re: LCD Toshiba
What have you tried so far?
By
Phil Bridges
·
#249164
·
|
Re: D3Pro with Cameo Keypads 6Btn Issue
#d3pro
#cameo
I you problem wanting to use CBD 6 btn config (like God intended), or to swap CB models for CBD models?
By
ckangis
·
#249162
·
|
Re: VC-4 USB Ethernet no longer possible
#vc4
I have confirmed it was removed temporarily and will be back.
By
cmac_HT
·
#249161
·
|
VC-4 retrieving LPZ
#vc4
Does anyone know where the .lpz is stored on a vc4 box?? I would like to have the option to retrieve the lpz before doing things like updating the linux version or the VC-4 version, in case something
By
Mike Taylor
·
#249160
·
|
Re: Q_SYS Crestron Certified Modules version 5.0 and 5.1
#cp4
#q-sys
Just downloaded the 5.2 version, the PIN is back as a parameter and the seem to have fixed the library naming problem according to the release notes. V5.0 ¨C Recompiled with Newtonsoft v4.0.8.0 for
By
Olivier Royer
·
#249159
·
|
LCD Toshiba
Hi, Im try power on and off two monitor Toshiba but everthing found doesn?t work. The model is TD-E501 If you had any information to control this it would be of great help. Thanks
By
Juan Lopez
·
#249158
·
|
D3Pro with Cameo Keypads 6Btn Issue
#d3pro
#cameo
I think I have a solution for most of my problem here,? I dug up an old D3Pro project that had 6btns on it and got an engraving file out of there. Next, I took it and put it into a different project
By
james@...
·
#249157
·
|
Re: Steamist port for communication
John, This is not directly related to your specific symptoms, but I've found that a lot of quasi-tech devices like this have an issue with Wifi SSIDs that supply both 2.4 and 5g. If you haven't
By
ckangis
·
#249156
·
|
Re: VC-4 USB Ethernet no longer possible
#vc4
Only on Pc3?
By
cmac_HT
·
#249155
·
|
Re: Poly "Partner Mode" - external control?
It's been awhile since I tested, but I don't believe there is much control available. You have access to the commands that change the modes on the unit and query what mode it is in, etc... But nothing
By
Andy Ross
·
#249154
·
|