Re: Does anyone have an AirMedia 2 series operating system image?
No, we have 200s that technically belong to customers as spares. I'm sure a handful of people have sandbox units or old ones from dated installs. Just curious if someone has tried it/has managed to
By
Sam
·
#247761
·
|
Re: Crestron Home simple relay driver
Thank you all for your help and suggestions, I already have CP3 with Crestron Home Triggers events, but finally I want to remove CP3 and use only CP4-R. The best for me could be simple driver to
By
kamil.rukat@...
·
#247760
·
Edited
|
Re: TSR-310 xPanel test
Thanks, Dave...I always appreciate you getting us the answers that we need, even if it ticks (me) off...:) Consistent inconsistency in the last few years has added to our suffering out here in the
By
ckangis
·
#247759
·
|
Re: VTP Reserved Join: Start SONOS
That's what I thought, just wanted to confirm, Thanks!!
By
ckangis
·
#247758
·
|
Re: CP4 -> D3 Program (on same CP4) -> CEN-GWEX-ER: No communication with CLW-SWDIMEX-P's
Thanks for the replies guys!? Will definitely check these out if I run into the issue again.
By
XSDS
·
#247757
·
|
Re: TSR-310 xPanel test
TSR-310 doesn't support XPanel emulation; official stance is that you need the physical remote to test at this time. When running a TSR-310 .vtz as XPanel you won't have an option to Enable Faceplate
By
Dave H - Crestron True Blue Tech Support Engineer Since 2014
·
#247756
·
|
Re: CP4 -> D3 Program (on same CP4) -> CEN-GWEX-ER: No communication with CLW-SWDIMEX-P's
Yeah, I ran into basically the same issue last week as well.? Roiling the firmware back to 1.4230.0015 resolves this.? For reference, https://support.crestron.com/app/answers/detail/a_id/1001572
By
cheinemann.605@...
·
#247755
·
|
Re: CP4 -> D3 Program (on same CP4) -> CEN-GWEX-ER: No communication with CLW-SWDIMEX-P's
What is your CP4 set for when you run SECUREGATEWAYMODE? If its Default it should accept secure and non-secure connections.
By
@johnmax
·
#247754
·
|
Re: VTP Reserved Join: Start SONOS
That reserved join opens the Sonos App on a TSW panel. I have used it way back when Sonos was first controlled (poorly) by Crestron and before they gave you the jump thru the Media Player Sonos icon.
By
@johnmax
·
#247753
·
|
Re: DSC PowerSeries Neo
Did you log in with a dealer/partner level account at support.crestron.com to gain access to the Online Help article? OLH 1000527 = Crestron Certified Drivers: SIMPL Windows (
By
Dave H - Crestron True Blue Tech Support Engineer Since 2014
·
#247752
·
|
Re: Crestron Home simple relay driver
Apologies Kamil but I misread your original post. Our CCI Bridge module only currently works with 4-series so would not be a good solution for the CP3 at this time.
By
minimalister
·
#247751
·
|
Re: CP4 -> D3 Program (on same CP4) -> CEN-GWEX-ER: No communication with CLW-SWDIMEX-P's
Just ran into this myself...? TB recommends setting up a "connects" user profile in the CP4. Then in the gateway, text console the following command. SETCSAUTH -N:username -P:password Using the new
By
dreevely
·
#247750
·
|
Re: Crestron Home simple relay driver
Ultamation have a similar solution to the CC bridge (though ours isn't free), though in this case, I'm guessing that the standard Crestron Home Triggers (in SIMPL, "Pyng (Listen for Pyng Events) v1.1
By
Oliver Hall
·
#247749
·
|
Re: DSC PowerSeries Neo
In Crestron-land things that end .pkg are a Crestron Certified Driver.? That could be either an IR file for Crestron Home, or a driver bundle like the one you're looking at. Apologies if this has
By
Oliver Hall
·
#247748
·
|
Re: DSC PowerSeries Neo
I understand the downloaded zip file contains a .PKG file, renaming this .PKG file to .ZIP and use an unzipping program, you can see the contents being just these few files:
By
lo@...
·
#247747
·
|
Re: Sending IP commands to Crestron end points from third party software
There is an API for NVX https://sdkcon78221.crestron.com/sdk/DM_NVX_REST_API/Content/Topics/Home.htm
By
Shawn Fennell
·
#247746
·
|
CP4 -> D3 Program (on same CP4) -> CEN-GWEX-ER: No communication with CLW-SWDIMEX-P's
This is just a cautionary post (perhaps for my own sanity next time I run into the problem). Had a project today that has a CP4 and roughly 40 or so CLW-SWDIMEX-P's.? For me, its easier to manage my
By
XSDS
·
#247745
·
|
Re: VTP Reserved Join: Start SONOS
Yup, got all that...Just was wondering what the reserved join is supposed to do...
By
ckangis
·
#247744
·
|
Re: Crestron Home simple relay driver
As a quick fix, if you can keep the CP3 just for the ports and to run a SIMPL Windows program to continue to control open, close and stop then you can link that program to CP4-R and use our Crestron
By
minimalister
·
#247743
·
|
Re: Crestron Home simple relay driver
I wrote an article for Residential Tech Today on writing an extension driver for Crestron Home. I¡¯m traveling right now so providing a link is a bit challenging. If you search for my name on the
By
jbasen
·
#247742
·
|