This is just a cautionary post (perhaps for my own sanity next time I run into the problem).
Had a project today that has a CP4 and roughly 40 or so CLW-SWDIMEX-P's.? For me, its easier to manage my lighting in D3 as I am used to it and its just a bit more manageable.? So, built a D3 program with a CEN-GWEX-ER in it with all wireless keypads attached.? Bing, bang boom, Done.? Load program to Slot 3 on the same CP4 my main program is running on.? Done.? IP table on the CP4 in toolbox says everything is connected on port 41794, ethernet intersystems good, CEN-GWEXER good, good to go.
IP Table on the gateway using port 41796, offline..... Well thats weird....
Test manager saying all things talking and working fine, time, loads, buttons, all good.? But local wireless keypads are still only working in local mode and not communicating to program..... Super weird.
SKIP FORWARD AFTER TRYING AUTH settings, changing ports, nothing working.
Roll back firmware on the CEN-GWEX-ER to previous forced auth, I think it was 4.230 or something.? Remove previous IP table, place new instance in, voila, talking on Port 41794.? All devices are working.
Looks like for some reason in how D3 is building or loading the project, I havent exactly determined if this can even be changed, it will not set the port to the secure port of 41796 and it will not work.? So rolling back the firmware on the gateway so authentication is disabled, allowed everything to work correctly.
Just a heads up if anyone runs into said issue.? Feel free to comment if I should have done something else, or missed something.
Thanks!