AV3 not communicating after power outage
I have an AV3 that is not communicating. No LAN light on the front but network activity on the port and on the network switch. I changed to DHCP and it is not acquiring an IP. Errlog reports the
By Michael Benignus · #237997 ·
Re: Lutron integration issue
I just RMA'd a AV3 because it would stop talking to Lutron.? Delete license, get a new one and everything was good for 6 months until it did it again.? Same fix as before.? They sent me an advanced
By John Gabler · #237996 ·
Sony Z Series TV control not working
Anyone dealt with the new Sony Z Series Displays? I have tried CEC, IR (several drivers), RS232. nothing. Even other Sony tv remotes wouldn't control the tv (just power toggle, but no menu or other
By j5races · #237995 ·
Re: Compiler Error "Local" #simplwindows #crestron #lighting
Should not be too hard to fix.? Once you find the offending module open it, search for the variable LOCAL, and rename it to something else like LOCAL2.? Sometime in the past, LOCAL wasn't a reserved
By Steve Kuehn · #237994 ·
Re: 3 series Processor Auto hard reset - looking for Opinions on Doing it daily
BTW, the #2 needs to be there if you are using the latest update of the scheduler.
By Evan Kontos <ekontos@...> · #237993 ·
Re: 3 series Processor Auto hard reset - looking for Opinions on Doing it daily
You need to also look at the .dat file.? There needs to be what appears to be an errant line at the very top,? #2, and the file MUST be in the NVRam folder on the processor and in the subfolder for
By Evan Kontos <ekontos@...> · #237992 ·
Re: Honeywell 4232BCM v1.4 and Vista 20p
I've seen a couple of defective 4232CBMs, however if that were the case the older module wouldn't work. I'd suspect either the alarm panel's or the 4232CBM's firmware needs to be updated. I can't
By Tony Golden · #237991 ·
Re: 3 series Processor Auto hard reset - looking for Opinions on Doing it daily
Hello Evan, I have only one event in the .dat file to trigger the hard reset at 3am, I tried only Saturday¡¯s, tried everyday and still nothing. I user text console to set time to a few minutes
By Jose Yanes · #237990 ·
Re: 3 series Processor Auto hard reset - looking for Opinions on Doing it daily
Hello Lincoln, Not hard resetting for any issue related reason, I just want to reduce the runtime so that I do not have 180 days plus of uptime. My main objective is to just have my system uptime
By Jose Yanes · #237989 ·
Re: 3 series Processor Auto hard reset - looking for Opinions on Doing it daily
Generally if you¡¯re resetting a processor with any frequency, let alone daily, it¡¯s a symptom of a bigger issue that you should really track down and fix first. I have many processors with a
By Lincoln King-Cliby · #237988 ·
Re: 3 series Processor Auto hard reset - looking for Opinions on Doing it daily
the scheduler can only kick off one event at a time so if you have 3 events that need to happen at 8:15 it will only do the last one.? Found that out with my thermostats.? had to separate them by a
By Evan Kontos <ekontos@...> · #237987 ·
3 series Processor Auto hard reset - looking for Opinions on Doing it daily
Hello All, I¡¯m looking for everyone¡¯s opinion on doing a hardware reset on my 3 series processors Automatically everyday at 3am. I was trying to use the event scheduler to perform the Hardware
By Jose Yanes · #237986 ·
Re: Honeywell 4232BCM v1.4 and Vista 20p
I'm not in front of it right now, but I'm using it with a PRO3 and it's been working for quite some time in other locations as well.
By Dan Gawne · #237985 ·
Re: Compiler Error "Local" #simplwindows #crestron #lighting
Thanks for the replies (BB, Jeremy, Steve) BB - tried ... no luck Jeremy - tried ... no luck ... dont want to back load SW as my other programs would suffer... Steve - best advice... i didn't think of
By Ivan Wild <c_rezz@...> · #237984 ·
Re: Compiler Error "Local" #simplwindows #crestron #lighting
I believed I seen this back years ago in one of my programs.? It turned out to be signal in a module that was named "LOCAL" -- it wasn't even a module that I wrote.? If you do have a signal named
By Steve Kuehn · #237982 ·
Re: Issues with Sonos & Crestron
Most common cause is not recompiling the SIMPL program properly. *FW v1.603.0113 requires SIMPL program running must be compiled with DevDB 91 [Jul.2020] or later.* *Also make sure you use Recompile
By Dave H - Crestron True Blue Tech Support Engineer Since 2014 · #237981 ·
Re: crestron/napco secutiry panel
Hi, any luck with this?
By ace plagata · #237980 ·
Napco Ibridge
Hi all, Just wanted to ask if some of you have been able to integrate Napco Ibridge and Crestron? I can change the parameter of the Napco ibridge but still with no prevail. thanks in advance.
By ace plagata · #237979 ·
Honeywell 4232BCM v1.4 and Vista 20p
Hi, Has anyone been able to make the Honeywell 4232BCM version 1.4 module work with the Vista 20p alarm panel and a CP3? I cannot get any communication back from the device (alarm panel) on version
By Keith Ilesic · #237978 ·
Re: Compiler Error "Local" #simplwindows #crestron #lighting
Local is a virtual signal that the compiler reserves (along with 0 and 1), although I don't know how it's used. I would try Project/Resync Project, or go back to an older version of your SMW,
By Jeremy Weatherford · #237977 ·