TSW-x52 non Crestron mac address
Anyone ever seen a non Crestron mac address on a TSW panel?? I just picked up one off Ebay and it doesn't have the usual 00:10:7f mac address.? I couldn't imagine how to change it back to match
By
plareeeiybusse
·
#235850
·
|
Re: Insteon Lighting Control
My email is Julio@....
Thank you for letting me take a look.
Im still trying to get it working with the SmartLinc serial interface but its not working for me.
By
julio@...
·
#235849
·
|
Hayward OmniLogic Crestron Module
Does anyone have any experience with integrating these water systems?? We always utilize Jandy or Pentair so this is the first time looking at this one.? It seemed pretty straightforward with
By
XSDS
·
#235848
·
|
Re: Insteon Lighting Control
Michael and Julio;
Hmm, I could try to create a smw file with an extract of the ISY content.
Is there a way you can maybe message me your email addresses to send it to?
Again, fair warning, it is
By
waffles
·
#235847
·
|
Samsung Flip2
Hi all,
I need control the new version from Samsung Flip Monitor, (Flip 2 WM55R and
WM65R). someone had a success to control?
I can control to previews version, but not on this newer; The
By
TBB Automacao
·
#235846
·
|
Re: DIN-AP3 D3 Program and C2N Keypads Amuck
Weird.? For whatever reason a firmware update and reboot seemed to alleviate the problem.? Not sure if it has something to do with current software versions and previous firmware versions.? Hidden
By
XSDS
·
#235845
·
|
Re: Insteon Lighting Control
Do you have a file that I can use as an example?
By
julio@...
·
#235844
·
|
Re: Insteon Lighting Control
Would you be willing to share any of your setup? I had a full Insteon house with an ISY controller before I started working with Crestron and now I¡¯d like to integrate the two, but I¡¯ve never had
By
Michael Fletcher
·
#235843
·
|
Re: LG RS-232 Pinout
I have a different TV (LG OLED C8), but these are notes I took when I hooked it up:
? DB9 Pin 3 to 3.5mm Tip
? DB9 Pin 2 to 3.5mm Ring
? DB9 Pin 5 to 3.5mm Sleeve
Also check
By
waffles
·
#235842
·
|
Re: Insteon Lighting Control
I have my CP3 talk to an ISY through REST commands. This allows me to control Insteon devices and scenes. I am also able to get some status feedback via query commands. Not very pretty, but it works
By
waffles
·
#235841
·
|
Insteon Lighting Control
I am having a hell of a time trying to control some insteon lights. I attempted to use the lighting and thermostat module in the files section but it does not seem to compile in a 3 series
By
julio@...
·
#235840
·
|
Re: Just posted Insteon lighting & thermostat control modules that I developed
Hello, I have tried this module on a CP3N and it does not compile. There is an error on Line 86 of the module. I am guessing its a bit of cone that is not compatible with a 3 series processor. Has
By
julio@...
·
#235839
·
|
Re: Smart Labs Insteon Lighting
Hello, I am interested if anyone has gotten this to work? I have a project with a bunch of Insteon dimmers to control.
By
julio@...
·
#235838
·
|
LG RS-232 Pinout
Hi everyone,
We are installing an LG display ( 86UH5E ) with RS-232 control through the 4-pin TRS connector.
Does anyone know which connections on the display are TX, RX and
By
Andy Ross
·
#235837
·
|
Re: LG Refrigerator Module
Looks like pages 4,5,6 have Refrigerator info!
By
j5races
·
#235836
·
|
Re: DIN-AP3 D3 Program and C2N Keypads Amuck
We had something similar recently and it all devices would show up fine but I noticed an intermittent flood of update requests from a certain Cresnet ID. We swapped the keypad and our troubles went
By
@johnmax
·
#235835
·
|
Re: KNX, which gateway? CI-KNX or CGEIB-IP?
The biggest difference (except for the group address count) is that You need a KNX guy every time You need to make a change on CI-KNX. This unit needs to be programmed on KNX side (ETS software). If
By
Peter Jablonicky
·
#235834
·
|
KNX, which gateway? CI-KNX or CGEIB-IP?
I have worked on a number of projects integrating with KNX using a CGEIB-IP, which seems to work pretty well. A few years back a Crestron employee suggested to me that we should always choose the
By
Bruce Bartlett
·
#235833
·
|
Re: 24VDC power supplies in metro DC?
Ugh¡. So close but just not quite ? -- several 12V options and a Lenovo 20V option that I could probably hack a new end onto and would probably work but nothing @ 24V
Appreciate the offer but
By
Lincoln King-Cliby
·
#235832
·
|
Re: 24VDC power supplies in metro DC?
Good luck. If you¡¯re in need I stock a few in my basement for my system, I can give you a couple, but I¡¯m a little further out from Vienna. Arrangements can be always be made so let me know.
EJ
By
EJ
·
#235831
·
|