Re: Front panel PSPHD
Heath,
Do you even need standby? SRC=0 should 'turn it off', right?
Or does standby actually work as a power button like on an AVR, where it shuts the unit down... Q: Is there really a power draw
By
ckangis
·
#181068
·
|
Re: Front panel PSPHD
Dave
I'm using nine signals to run the PSPHD. All on the main symbol: Standby, MuteOn/Off, InputSelect, VolumeMain, Min/Max/StartupVolumeMain and PowerOn_F.
Two on the amp: PowerOn/Off.
I'm not
By
Heath Volmer <hvolmer@...>
·
#181067
·
|
Re: SMRX with SIMPL+?
Thanks Jeremy!
Yeah the missing "non-special" multiplexor seems a bit strange.
The special symbols include data length and a checksum according to the
docs, so it could potentially be better for
By
Crestron Noob
·
#181066
·
|
Re: Front panel PSPHD
I have not used the PSP yet, but I would bet that successful control can be achieved with very few signals, as was the case with the DAP8.
When I setup my first DAP8, I used the 'Demo' program and
By
ckangis
·
#181065
·
|
Re: Water level sensor
I haven't worked with these ones, however for similar projects, I've used maritime bilge alarm float switches.
Try to find a yachting / marine supplies store and they should be able to assist as
By
Specialty Programming
·
#181064
·
|
Sony KDL-40EX640 IR Module
Anyone have any experience with this specific Sony TV? I'm running into a ridiculous amount of issues trying to get it to switch to the composite video input using an IR probe. If theres anything
By
joshaimm1992
·
#181063
·
|
Re: Water level sensor
Thanks, how does that communicate to Crestron? Do you have a link?
By
Rogier van Steeg
·
#181062
·
|
Re: Water level sensor
It says it can detect "low water conditions", so I would take that to mean
it's okay with being normally submerged. Might be worth double-checking.
I know another type of tank sensor bounces
By
Jeremy Weatherford
·
#181061
·
|
Re: ClobalCache WF2IR connection problem
I believe the GlobalCache wireless devices are 802.11b, which is a dying
breed and may not be supported by newer wireless routers unless you enable
11b compatibility (which slows down
By
Jeremy Weatherford
·
#181060
·
|
Re: STX-1700 reconnect issue
It's been a while, but I would say that best practice would not be to have assigned STX panels on more than one GW. Did you mean ST-1700? or are you in fact using STRFGWX units, all three set to the
By
ckangis
·
#181059
·
|
SMRX with SIMPL+?
Sure, it's useful for routing lots of serial signals together:
STRING_OUTPUT MuxOut$;
//...
STRING value[250]; // value to send
INTEGER join; // join number to use
//...
makestring(MuxOut$,
By
Jeremy Weatherford
·
#181058
·
|
Re: reccomendations for free webmail
I have been using lavabit.com for many years.
By
TechyJake <techyjake@...>
·
#181057
·
|
Re: MLX-3/Duplicate Device Programming
I am soooooooo happy that they did this as well! Oh, how I wish we could just import the VTP file and it would set up the proper page types and matching names for us automatically! Unlike others, I
By
TechyJake <techyjake@...>
·
#181056
·
|
Re: Motorola DCX700-M cable box
I haven't used that particular box but I'll post a file that might work for you. It's for the Comcast DCX3400 - This is Comcast's 'dark silver' remote code set. It's worth trying...
IIRC, I had
By
ckangis
·
#181055
·
|
New file uploaded to Crestron
Hello,
This email message is a notification to let you know that
a file has been uploaded to the Files area of the Crestron
group.
File : /IR Drivers/Comcast Motorola DSX3400.ir
By
Crestron@...
·
#181054
·
|
Re: ClobalCache WF2IR connection problem
Make sure you have it's IP address listed in the tcpip client. That always
gets me. I'm sure you already checked that. And I think you can change the
port to something else on the global cache side
By
kaybee302
·
#181053
·
|
MLX-3 setup screen from inside the program
I need to be able to bring up the setup screen for the client without having to press MEDIA ,LIGHTS, (Crestron symbol) and GUIDE.. TWICE in a row.. This is clunky and awkwards and the client will
By
K7XYM
·
#181051
·
|
Re: How to force a MLX-3 to load a new program
They can get stuck at loading program.. Ive found taking the batt out for a bit and putting it back has usally caused it to load. However I remember having to call True Blue once as it was NOT loading
By
K7XYM
·
#181050
·
|
Re: ClobalCache WF2IR connection problem
Thanx Chip! You're right: the QM-RMC couldn't ping the WF2IR. I checked a different Wifi router (linksys WRT54GL) and the connection worked! Back on the original router it worked to. So I don't really
By
controlfreakberlin
·
#181052
·
|
SMRX with SIMPL+?
Hi, has anyone used S+ string output to feed Serial Demultiplexor
or the "Special" version?
I have a module that desperately cries for configurable number of
serial outputs (without recompiling), but
By
Crestron Noob
·
#181049
·
|