Re: LG Display IP Control WOL

 

Just wanted to share that I've discovered that Wired Wake On LAN can be changed without the remote control by sending the "fw id data" command, where data is 00(Off) or 01(On). For example, "fw 01 01".


Re: Alert! concerning the PC-350V power controllers

 

So, going on UPS power worked now?


Re: Alert! concerning the PC-350V power controllers

 

Just a follow-up. Today I updated my PC-350V's with the latest/new FW to resolve (Hopefully!) the issue noted in this thread.
Obviously its too early to tell how things will go, but initial tests seem good.

The one notable item was that when I updated the FW, the outlets DID NOT cycle, so that was a pleasant surprise!!! hopefully this is part of their design, as I HATE when PDUs cycle their outlets with updates...


Re: Crestron App

 

also check on the iPad settings, scroll down to Crestron Go, make sure "use local network" is switched ON.


DM-NVX-E30 / D30 and Dolby Atmos

 

I have been unable to get Dolby Atmos to work from an Apple TV using NVX encoders / decoders.? Just updated NVX firmware to 7.0.? I've tested with both a McIntosh MX-180 and a Yamaha CX-A5200 Preamp.? I've tried several different EDIDs which don't seem to work.? The issue is no audio passes at all to the AVR.? I'm wondering what anyone else's experiences are with this?

What we've had to run Apple TV directly to the AVR then AVR HDMI Out to the NVX Encoder so our display can get video.


Re: Crestron Home BACnet HVAC

 

I had some issues with YABE, only one CMNgw at id 64, but yet not discovering, etc.
I tried with also with BDT (bacnet discovery tool), and it reported the units fine.
It didn't report the information we need in a useful manner to me, but yet it helped me diagnose.?
In the end, and can't remember why, yabe worked.


Re: Crestron App

 

If authentication was enabled in the PRO3, check if IP got blocked.
'Remblockedip'


Crestron App

 

Greetings all .I had an app project working fine .it was local only .suddenly stopped. Says connection refused .I have updated firmware , all data bases still says the same .any ideas ? Its on a pro3


Re: VS 2008 Can't Open Crestron Projects

 

Microsoft released an update which should fix the issue:?2022-05 Cumulative Update for .NET Framework 3.5 and 4.8 for Windows 11 for x64 (KB5013628)

--
?
Crestron Service Provider - TBD Enterprises Inc.


Re: CCDs and NVRAM

 
Edited

SIMPL+ NVRAM allocation was introduced in CCD Disp Eth v1.14.
(F1 Revision History calls out "Added ability to page through more than 10 user attributes.")

SIMPL compiler calls out max NVRAM allocation for the program slot after adding 20-something CCD Disp Eth v1.14+ instances.
For now the workaround is to use CCD Disp Eth v1.13 or split the CCD Disp Eth v1.19 module instances into multiple program slots.

The Driver team is working to utilize SIMPL# (instead of SIMPL+) for holding the persistent data to correct this behavior.
I don't have an ETA for the module update that will accomplish this, but it is something we're tracking, and I'll update the thread when I know more.


Re: CCDs and NVRAM

 

Well must be a hold over from 2 series in Simpl, crisis averted.? I checked the PRO4 and it actually has 3MB of NVRAM.??


Re: QSX Keypad Buttons Presses

 

Hi there! You would use the feedback signals of the?Lutron HomeWorks QSX Button Control v1.1 module. The outputs of that module will go high when the corresponding physical Lutron keypad button is pressed and low when it's released.?


CCDs and NVRAM

 
Edited

Learned a valuable less today.? I am using the Sony IP CCD modules for both TV and Receivers.? Apparently they are NVRAM hungry.? Each CCD allocates about 10KB of NVRAM.? I am just updating a program with 24 rooms and each room is mostly duplicated to make it easy to expand.? First time every that I got the warning that my program has exceeded the allotted NVRAM of a processor, PRO4 fyi.? Now to go back through and comment out the CCD's I don't need.


Re: Wake On LAN (WOL) Help!

 

Thanks for all the advice and suggestions!?

I ended up doing what Dave H suggested (one of his suggestions) and made my magic packet string in Notepad and copied/pasted into an SIO. I had to put a 1 on my UDP symbol to get it to work. I'm not sure if leaving the UDP module latched on is "best practices" but it works.

Also, since the TV is on the DMPS3 control subnet I used 172.22.255.255 as the broadcast address in the UDP symbol.

I'm having rock solid success with CEC on projects ?but this TV is feed from a Kramer HDMI DA which only passes CEC to the first output. Because of that I could not uses CEC on this one TV out of five. ?It was a lot of trial and error and lessons learned on using the right hardware to avoid this in the future.

Best,
David?


Crestron Home BACnet HVAC

 

Cool automation and Crestron Home BACnet, YABE
We have 1 CoolinkBridge ID 64 showing a HVAC system detailed BACnet data for Thermostat - operation is good in Crestron home? YABE show all BACnet info for this device ID64. But when we added more CoolinkBridge Unit ID 65 and 66 for HVAC system 2 and 3 we get no detailed BACNet information from YABE just the device on the tree - 65 and 66 come online as devices in HOME but without detailed BACnet we can not adjustment points.

Dose the DAIKIN HVAC only operate with ID 64 with CoolinkBridge?
Is YABE maybe not able to see device details
Anyone with some information would be awesome - at a loss with this one.

Mark G


Re: Wireless radiator valves (UK project)

 

I should also add that the Shelly TRV can be fully controlled through the Shelly app.

Thanks?

Jay

On Wed, May 11, 2022 at 7:00 AM jbasen via <jay.m.basen=[email protected]> wrote:
Correct. All Shelly devices communicate directly over WiFi so they don¡¯t require a hub

And, the Shelly drivers I¡¯ve written will run on either a 3 or 4 series processor. All the source code is also included on my GitHub so if there is a feature of the device I haven¡¯t included in the driver you can simply add it yourself?

Enjoy?

Jay

On Wed, May 11, 2022 at 5:58 AM nick_masterson_uk <nmasterson@...> wrote:
Hi Jay,

many thanks for the info!

No, the TRV referred to wasn't a Shelly one, it was old school mechanical with a capilliary tube!

I have downloaded your demo files, and have contacted the supplier to see if they will ship to the UK (Brexit having made EU supply of all simple things much more complicated!!).
Looking at the program, and the Shelly website, I am guessing all I need are the TRVs, a 3/4 Series processor, and decent WiFi coverage. No third party hubs/controllers/etc. ?


Re: Wireless radiator valves (UK project)

 

Correct. All Shelly devices communicate directly over WiFi so they don¡¯t require a hub

And, the Shelly drivers I¡¯ve written will run on either a 3 or 4 series processor. All the source code is also included on my GitHub so if there is a feature of the device I haven¡¯t included in the driver you can simply add it yourself?

Enjoy?

Jay

On Wed, May 11, 2022 at 5:58 AM nick_masterson_uk <nmasterson@...> wrote:
Hi Jay,

many thanks for the info!

No, the TRV referred to wasn't a Shelly one, it was old school mechanical with a capilliary tube!

I have downloaded your demo files, and have contacted the supplier to see if they will ship to the UK (Brexit having made EU supply of all simple things much more complicated!!).
Looking at the program, and the Shelly website, I am guessing all I need are the TRVs, a 3/4 Series processor, and decent WiFi coverage. No third party hubs/controllers/etc. ?


QSX Keypad Buttons Presses

 
Edited

Hi, first time doing Lutron QSX...I have the HomeWorks QSX v1.1 module from the Application Marketplace and I do not see a way to receive button presses into Crestron from a Lutron keypad. I want to know if someone pressed, double tapped, held, and released a button on a Lutron keypad. Is there a way to do this using this set up modules or is there another way?


Re: Wireless radiator valves (UK project)

 

Hi Jay,

many thanks for the info!

No, the TRV referred to wasn't a Shelly one, it was old school mechanical with a capilliary tube!

I have downloaded your demo files, and have contacted the supplier to see if they will ship to the UK (Brexit having made EU supply of all simple things much more complicated!!).
Looking at the program, and the Shelly website, I am guessing all I need are the TRVs, a 3/4 Series processor, and decent WiFi coverage. No third party hubs/controllers/etc. ?


Re: Samsung IP control with CCD

 
Edited

?
?

/g/crestron/message/245762?
/g/crestron/files/WakeOnLAN%20Examples%20-%20UDP%20and%20Crestron%20Certified%20Drivers.zip?

I downloaded the QN55LST7TAFXZC driver and inspected the UserAttributes (below) as described in OLH 1000527.
Have you confirmed MACADDR$ (and other required UAs) is being sent into the module properly and WOL magic packet is seen when PWR ON is pulsed?
It may be prudent to confirm network topology & settings aren't blocking broadcast packets.

UA1 = Device Settings = To configure for IP control, use TV remote and press Home button, navigate to Settings > General > Network > Expert Settings, turn on \"Power On with Mobile\" and enable \"IP Remote\" settings. Then follow Enable Instructions
UA2 = Device Settings = To enable IP control, begin with TV powered on, then while driver is being loaded, look at TV for message to allow IP Remote control, use TV remote to select Allow, for control
UA3 = String Input Required Before Connection =?Mac Address of Samsung IP Device.?This is required to turn the Display on. Please provide in the format of AA:BB:CC:DD:EE:FF.
UA4 = WOL Notice =?Since this device uses Wake On LAN to power it on, the driver can have an extended warmup time where control may not be available for several tens of seconds. Please note this for this driver.
UA5 = String Input Required Before Connection =?DefaultDigitalCableChannel =?The digital cable channel displayed when selecting the digital cable source for the first time.?This is required to be able to set the channel when a cable service is being used as the TV source for digital channels.
UA6 = String Input Required Before Connection?=?DefaultAnalogCableChannel =?The analog cable channel displayed when selecting the analog cable source for the first time.?This is required to be able to set the channel when a cable service is being used as the TV source for analog channels
UA7 = String Input Required Before Connection?=?DefaultDigitalAntennaChannel =?The digital antenna channel displayed when selecting the digital antenna source for the first time.?This is required to be able to set the channel when an over the air antenna is being used as the TV source for digital channels.
UA8 = String Input Required Before Connection?=?DefaultAnalogAntennaChannel =?The analog antenna channel displayed when selecting the analog antenna source for the first time.?This is required to be able to set the channel when an over the air antenna is being used as the TV source for analog channels.