¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: CP3-R difference

 

I think that the 'R' means lots more RAM, needed for the Pyng/CH apps...

Also note, I don't think that there's any way to use the 'R' version for standard SMW projects...:(


Re: CP3-R difference

 

Always curious why they used the suffix "-R" for these devices instead of -P (pyng) or -H. Is R some kind of internal code name?


Re: NAX Traffic crushing network

 

Hey John,
I haven't fully thought this thru yet, but I think that if you just set up the streaming ports on the NAX units to a separate switch and then use the other/non-streaming ports for control on the main network - basically a hardware wall between the two communication types...
This is not the ultimate solution, but it could get you done for now...

Tom Brady (not the Quarterback!) at Crestron would be the guy to review this with, Send me an email if you want his contact info...


Re: Launching a 3rd party app from the crestron go app #crestronapp

 

I think that the problem may be what I think is trying to launch a 'Native' app - Others please weigh in on this as I'd like to know as well...

Ex: I used to use remote:// to launch the Apple TV remote app, than Apple decided to make things 'better' by making it a 'native' app and putting it in the system tray...
Now I can't get it to work...I'm thinking that CALC may be the same...

Would also Love to hear a way around this to make it work...


Re: Launching a 3rd party app from the crestron go app #crestronapp

 

You need to send it the URL and then hit the send, I just use a sos to make it simple.? The trick is finding the URL for the particular app you have in mind, some examples: "Sonos://", "ZoomRooms://", "roku://".? I have never tried the calculator, maybe try installing one of these and testing, as I know they work.? Good luck


Re: CP3-R difference

Michael S Moran
 

¿ªÔÆÌåÓý

¡°R¡± designation alludes to Crestron Home configuration whereas the regular CP-3 supports Simpl deployments.?

Best regards,

Michael S. Moran

On May 16, 2022, at 6:48 AM, stefuel2 via groups.io <stefuel@...> wrote:

?What is the difference between a CP3 and CP3-R?? I have no PYNG experience.? Can the "R" be used stand alone with simpl?


Poly G7500 device mode command

 

I have tried using provider mode command in Poly G7500 API guide but when we change provider mode, the system restarts.
I want to change provider mode from poly to device mode without restart. Kindly provide commands for the same


CP3-R difference

 

What is the difference between a CP3 and CP3-R?? I have no PYNG experience.? Can the "R" be used stand alone with simpl?


Re: Back to the Future: Bulk CD Ripping!!

 

What Michael said!!


Re: Back to the Future: Bulk CD Ripping!!

 

With the impending release of the AMB and OS7 Autonomic claims that they will support a floor of 200K songs but that they might be able to do more.


Re: Back to the Future: Bulk CD Ripping!!

 

I would be a bit curious if an Autonomic could actually index that much music. I have about 40,000 songs on mine and it works fine, but you're talking 120-150,000 titles or more there. Has anyone here ever tried one with that number of titles?


File /Philips BDL 4635.ir uploaded #file-notice

Group Notification
 

The following files and folders have been uploaded to the Files area of the [email protected] group.

By: Ron.gillen@...

Description:
Philips BDL 4635 IR remote.


Re: NAX Traffic crushing network

 

I had a similar problem with NVX devices. ?I had to turn off spanning tree protocol on my Cisco switches on the VLAN with the NVX devices and that fixed the problem for me!


Re: NAX Traffic crushing network

 

So as I read and watch video.? It does seem that any switch that supports VLANs and IGMP should work in this small application. Since it is only 3 NAX units and no NVX.? It seems that they would co-exist fine on the flat network if IGMP was turn on, unless I am misunderstanding what I am reading.


Re: NAX Traffic crushing network

 
Edited

So there is no NVX yet.? What requirements in the switch would the NAX need?? There is an Araknis switch on site that has yet to be used. In this case I have conduits between systems, so I can get anything between the 3 amps.? Just to know for the future.


Re: NAX Traffic crushing network

 

¿ªÔÆÌåÓý

The Unifi switches will not handle anything NVX or NAX.? Those switches will need to be replaced in order for the network to stay up.

?

Pat M

?

?

From: "[email protected]" <[email protected]> on behalf of John Gabler <ComeAlive@...>
Reply-To: "[email protected]" <[email protected]>
Date: Sunday, May 15, 2022 at 3:19 PM
To: "[email protected]" <[email protected]>
Subject: [crestron] NAX Traffic crushing network

?

OK, we have a take over site that we are partnering with the original integrator that lost his installer/programmer.? The system was designed around a SWAMP +2 expanders linked via fiber.? Due to the inability to get the extenders, they upgraded to using 3 DM-NAX units on a flat network.? The house network is all unifi, accept for the router which is a Ubi edge router.? The issue that I am seeing, is like death by a 1000 cuts.? It doesn't show up initially, but when it does it will progressively get worse.? The NAX starts crushing the broadcast traffic on the network, which in turn screws with otherwise stable peripherals.? Wifi speeds go in the tank, crestron peripherals, like the CAEN-BLOCK-CENCN2's show online but none of the CLX modules have net lights.? Network printers stop working and other misc issues.

Just wondering if it is the Unifi or if we were to VLAN for connection to the 2nd ethernet port on the NAX would fix the issue.? Thoughts, knowledge or suggestions.? This site is 4 hours away on the tip of a peninsula and I will be going back up to complete this week.? Just wondering if I should be bringing parts.


Router vs Switches NVX system.

 

I am tasked with commissioning a large NVX/NAX deployment and lighting system in the next couple of weeks and we are still a ways out from receiving the spec'd router.? Just wondering for a temporary setup how important the router is?? Scenario is that I have 2 separately deployed flat networks, all extreme 54xx & 55xx switches. 1 aggregate and multiple switches for the data and WIFI and a mirror image setup for the DM NVX/NAX gear.? The only tie between the 2 networks will be the router.? All NAX units will have a connection to each network.? LAN1 for management/control and LAN2 for traffic.? NVX has a director that will also have connections to both networks while all NVX unit will be in the 2nd network.? The way I understand it, is that the important settings are in the switches.? Other then being the DHCP server and the ability to setup VLANS, is there anything special that I would need in a router?


NAX Traffic crushing network

 

OK, we have a take over site that we are partnering with the original integrator that lost his installer/programmer.? The system was designed around a SWAMP +2 expanders linked via fiber.? Due to the inability to get the extenders, they upgraded to using 3 DM-NAX units on a flat network.? The house network is all unifi, accept for the router which is a Ubi edge router.? The issue that I am seeing, is like death by a 1000 cuts.? It doesn't show up initially, but when it does it will progressively get worse.? The NAX starts crushing the broadcast traffic on the network, which in turn screws with otherwise stable peripherals.? Wifi speeds go in the tank, crestron peripherals, like the CAEN-BLOCK-CENCN2's show online but none of the CLX modules have net lights.? Network printers stop working and other misc issues.

Just wondering if it is the Unifi or if we were to VLAN for connection to the 2nd ethernet port on the NAX would fix the issue.? Thoughts, knowledge or suggestions.? This site is 4 hours away on the tip of a peninsula and I will be going back up to complete this week.? Just wondering if I should be bringing parts.


Re: Adding numeric info to liquid gauge

 

The simple way in VTPro is to add a "formatted text" item and click on the three little dots on the "label" field. It will open another window when you can choose an analog join and the format in which the analog value is to be represented.
Just reuse the same join the liquid gauge has.
You can also use a serial join and make something more complicated in Simpl, then transfer it in text format to the panel, but for 99% of the uses and the one you describe here, that shouldn't be needed.


Launching a 3rd party app from the crestron go app #crestronapp

 

I¡¯m trying to get the Crestron app to open other others on a clients phone, see link. I can get it to open websites on a browser and come back to the app via left hand return tab. I can¡¯t get it to launch another from the Crestron go app.?I¡¯ve built the code as per the article and try a few? URL schemes but they don¡¯t seem to open the corresponding apps. Eg ?calc:// didn¡¯t open the calculator. If I put http:www.crestron.com:// it opens the Crestron website. If I put http:www.google.com:// it opens google website both on the safari browser. I feel that I¡¯m missing something like prefix or suffix in the serial line.

Any advise would be appreciated??