Re: Hdmi CEC injection

 

¿ªÔÆÌåÓý

If you want to be a good Crestron soldier (or just have extra DMC-HD cards) ¨C use a whichever flavor of DMC-HD meets your needs in a DMCI cage.

?

Before I put? a DM fame in my house, I did this for Apple TV and Chromecsat control and it worked quite well ¨C and two of them on an ST-RMK made for? nice easy rack mount.

?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |

D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Audia Certified | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of davedunaway1@...
Sent: Friday, April 17, 2020 8:13 AM
To: [email protected]
Subject: [crestron] Hdmi CEC injection

?

What third party devices have y¡¯all seen to inject CEC commands into an hdmi link? I have seen the usb to CEC adapters, but are there any CI useful items with 232 or IR translation??


Re: Polycom Group Address Book

 

Hey Brian, thanks a bunch for your kindly reply!

I'll do it. In this project the Address?Book is the only gear that needs to be fixed.

All the best for you!

On Fri, Apr 17, 2020 at 10:21 AM Brian Erchenbrecher via <Brian.Erchenbrecher=[email protected]> wrote:

Louis, if you're using the stock v2.5 module from the Application Market, the address book functionality is WAY broken, and that's not the only thing wrong with it. The module hasn't been updated since February 2015 and has for all intents and purposes been abandoned by Crestron. Polycom has made lots of small changes in their API, some of them quite arbitrary, that have made different parts of this module nonfunctional or erratic as the years have gone by. If the address book is the only thing giving you headaches, that's not a bad place to be in, I suppose. I'd suggest running a search in the messages section of this forum, as I know this topic has come up before, and some folks had good suggestions at fixing this behavior. Hope this is helpful!


Re: Polycom Group Address Book

 

Louis, if you're using the stock v2.5 module from the Application Market, the address book functionality is WAY broken, and that's not the only thing wrong with it. The module hasn't been updated since February 2015 and has for all intents and purposes been abandoned by Crestron. Polycom has made lots of small changes in their API, some of them quite arbitrary, that have made different parts of this module nonfunctional or erratic as the years have gone by. If the address book is the only thing giving you headaches, that's not a bad place to be in, I suppose. I'd suggest running a search in the messages section of this forum, as I know this topic has come up before, and some folks had good suggestions at fixing this behavior. Hope this is helpful!


Re: Fusion Email Templates #Fusion

 
Edited

For the attribute: TP Password, I set an email notifications using email template below to be send when the password was changed changed (attribute updated):

Email template looks like this:
TP password in room:?[%RoomName%]?changed to:[%Serial%]

Actual email looks like this:
TP?password?in room:?MSS Test DMPS3?changed?to:?0000


Re: DM-NVX-351

 

As Tyler mentioned, there's an Extreme option in the X465 series, which can support 802.3bt, but they are indeed not cheap. They can be specified with different internal power supplies to provide enough power for all your endpoints. If you went with dual 2000-watt PSUs, though, they need to be provided with 200-240VAC to supply full power to the switch, otherwise you might as well stick with dual 1100-watt PSUs. Cisco also has the Catalyst 9000 series, which can do 802.3bt as well, but these are even a tier above the Extreme X465 in terms of price. I have not used the Microsemi midspan injectors nor the Planet UPOE hub mentioned, but I have used standalone Planet UPOE injectors with success. They seemed like quality products. If you're looking for a single-box solution, though, I'd recommend looking at the Extreme X465 series switches.


Hdmi CEC injection

 

What third party devices have y¡¯all seen to inject CEC commands into an hdmi link? I have seen the usb to CEC adapters, but are there any CI useful items with 232 or IR translation??


Re: CrestronApp prob. H264 stream (android)

 

Hi codefree,

Yes I did that the first time I tested the stream and it didn't work. :)
Yes it plays fine in VLC.
-s


Re: CrestronApp prob. H264 stream (android)

 

Hi?

>>>>>>
rtsp://IP_ADDRESS/rtsph2641080p
>>>>

That looks familiar. Have you turned off RTSP authentication in the camera setup? Default is on and in that case you need to add username and passwd to your URL. Does it work in VLC player ?
rtsp://user:passwd@IP_ADDRESS/rtsph2641080p


Re: CrestronApp prob. H264 stream (android)

 

Hi Tony,

That would be really helpful.
I've tried the following:
Primary H264:
rtsp://IP_ADDRESS/rtsph2641080p
http://<IP ADDRESS>/getimage?fmt=1080p

Secondary JPEG:
rtsp://192.168.2.253/rtsph264480p

Regards
-s


Re: Sudden nk.exe error in DIN-AP3

 

Steve & Joshua,

Thanks both for the replies - The AP3 does not have any ports open to the internet although there is a CP3 open for the app and that connects to the AP3 by an xsig - can't see that as an issue for the AP3 though.

I never use standard ports for anything to be fair - checked the router logs and no incoming.

I updated to the latest firmware and this has stopped the error but I take your point that it has to be an external influence and I will do exactly as you suggest and turn auth on on all processors.

Again, many thanks and stay safe,
Mark


Re: Fusion Email Templates #Fusion

 

Create an email template (Attribute).

Add a serial tag insert.

Go back to attributes TAB in setup and find the serial join data you want to be included in the email, Select the email rules TAB and find the template you just created. That will then add the serial$ data from the simpl program fusion join (Custom join 50 and above) To the email that fusion sends.

If you are monitoring devices attached to the processor (IPID), I would use the fusion SSI Equipment Status module. Perhaps you have a reason for serial data in the email in which case as above.


Re: CrestronApp prob. H264 stream (android)

 

Thank you guys,?
the hint from Maksym, regarding the embedded video app?s on/off join, seems to improve the bahviour.
What? I?m testing now: Keep this join off. When flipping to the surveillance page in the project, first send the video URL, wait 2 sec, set the on/off join to on. When switching to another camera, first set the digital join to off again. With a 1s delay, send the new stream ULR, again 1s dealy, digital join to on. When navigating away from the surveillance page, first set the digital join to off again.
One more finding, if the video doesn?t show, black screen, the camera?s OSD still shows an active connection. I haven?t wiresharked the traffic, but I assume the video is streamed, but not processed in the app.
Using the camera?s MJPEG streams and switching to MPEG in the app, doesn?t work at all.


Re: DM-NVX-351

Tyler Stirtz
 

¿ªÔÆÌåÓý

Extreme makes a Poe++ switch that will power 24 nvx. It¡¯s not cheap though. I¡¯d go the midspan route


On Apr 16, 2020, at 5:14 PM, AVMaster <home@...> wrote:

?I have an upcoming system that will require a 12x12 ish NVX setup but all endpoints and transmitters (350s or 351s) must be POE on a single switch.? I'm aware that the requirements are POE++ or 802.3b+ type 3.
Does anyone have any strong opinions on this?? Have any experience with a switch that can hang with the POE requirements?? Yes, locally powering them is an option but not in this case.? Thoughts?


Re: Polycom Group Address Book

 

Hi!

How are you doing?

The IT guy has configured the addresses. I can see the addresses going to Crestron, but for some reason the 2.5 module doesn't put it on its outputs. Smart Graphics are ok, I've tested it using a SIO logic. I've noticed this same issue being reported in other groups, but with no reliabe answers.

Em quinta-feira, 16 de abril de 2020, <christian@...> escreveu:

Are you sure there is an address book loaded into the Polycom?? Log into it using a web browser and check.? Also, I typically only use either the local or the global, not both, so make sure your smart graphic (I assume you're using a scrolling list) is tied into the right one.?


Re: Polycom Group Address Book

 

Are you sure there is an address book loaded into the Polycom?? Log into it using a web browser and check.? Also, I typically only use either the local or the global, not both, so make sure your smart graphic (I assume you're using a scrolling list) is tied into the right one.?


Re: CrestronApp prob. H264 stream (android)

 

I've programmed a few systems with Lilin cameras and NVRs, and they always worked great with Crestron. If you want, I can send some URL examples I used, and I may also have a protocol doc from their tech support.

--- On Thursday, April 16, 2020 at 4:40 AM, Slip Cougan wrote:

I've had no real issues with my Grandstream GXV3500 to my TSW-752's but I can't
for the life of me get my Lilin streams to work.


Polycom Group Address Book

 

Hi, group!

How?are you doing? I hope this message finds you well.

Well, I'm a newbie in this huge world?called Crestron, and today I was on field to integrate a Polycom Group 700 in a system already installed. Almost everything worked fine, but the ADDRESS BOOK (Local and Global) didn't work. In fact, I can see the addresses strings flowing from Group to CP3, but the group module (V 2.5) doesn't spit anything?out through its serial outputs (obviously, ADDRESS BOOK NAME # TEXT). Could you guys give me a tip to solve this issue?

Thanks in?advance!


Re: Losing URL encoding in S#

 

I also posted this on labs and someone there came up with a solution to double encode the embedded url

Thanks


Re: DM-NVX-351

 

We have used the Microsemi PD-9524GC 24 port midspan injector in the past for remote powering NVX units. I did also find the Planet UPOE-2400G injector but have not used it.


DM-NVX-351

 

I have an upcoming system that will require a 12x12 ish NVX setup but all endpoints and transmitters (350s or 351s) must be POE on a single switch.? I'm aware that the requirements are POE++ or 802.3b+ type 3.
Does anyone have any strong opinions on this?? Have any experience with a switch that can hang with the POE requirements?? Yes, locally powering them is an option but not in this case.? Thoughts?