¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date

Re: Lutron QS

 

Is this a Lutron QSX? That new processor? That unit has telnet disabled and won¡¯t work with a new module that is yet to be written. Login in to the Lutron IP from a web browser and see what the unit is on the info page


Re: CTI-P301

 

For sure go for it.?


I took it and then due to some life circumstances couldn¡¯t finish my cert exam. So 9 months later or so I decided to take the class again to get a refresh before I attempted the exam again.?


Thanks!
¡ª°­²â±ô±ð


Re: CTI-P301

 

Check these out in the meantime, plenty of files here to reverse engineer too.

?

--

?

Jeffrey Franck, CTS, DMC-E-4K

Audio/Visual Engineer

Chief Emergency Building Coordinator

Campus Media Services | WSU-TV

Media Resources Center | Room 178C

?


Re: need MTX-3

 

Sorry everyone.? Your responses were going to my Junk Inbox.? I'll contact you off-forum and fix the junk problem.


Re: CTI-P301

 
Edited

Thanks Joshua ?


Re: CTI-P301

 


You got this just do it. At the highest level it¡¯ll give you exposure to some new concepts and ideas. Hell you might just excel, and have some new tools for the tools box.?


Good luck?

J?


On Fri, Apr 10, 2020 at 7:22 AM TJP <Ssute01@...> wrote:
Interesting.. thanks Michael.
I always thought it was a pass/fail thing, and as such, I was worried I may not pass (due to my limited Simpl+ experience)
As this isn¡¯t the case though, I now feel more inclined to just give it a go, hopefully I can keep
up and pick up some new skills?

--


--
Joshua B Zimmerman

The beginning of knowledge is the discovery of something we do not understand.
? - Frank Herbert

This message, including any attachments, may include privileged, confidential and/or inside information. Any distribution or use of this communication by anyone other than the intended recipient(s?? The information contained in this e-mail and any attached documents may be privileged, confidential and protected from disclosure. If you are not the intended recipient you may not read, copy, distribute or use this information. If you have received this communication in error, please notify the sender immediately by replying to this message and then delete it from your system.? ? This email may contain confidential and privileged material for the sole use of the intended recipient. Any review or distribution by others is strictly prohibited.? If you are not the intended recipient please contact the sender and delete all copies.


Re: CTI-P301

 

Interesting.. thanks Michael.
I always thought it was a pass/fail thing, and as such, I was worried I may not pass (due to my limited Simpl+ experience)
As this isn¡¯t the case though, I now feel more inclined to just give it a go, hopefully I can keep
up and pick up some new skills?


Re: CTI-P301

Michael Larsen
 

¿ªÔÆÌåÓý

301 isn't something you have to pass. It's a prerequisite for the final Certification Exam, but, as such, it hasn't got an exam.?

I too attended 301 twice. I didn't have time to complete the Certification Exam after the first time and I felt that my Simpl+ was too rusty to pass, so I attended again. There was now additional cost involved.

/Michael

Fra: [email protected] <[email protected]> p? vegne af TJP via groups.io <Ssute01@...>
Sendt: 10. april 2020 14:01
Til: [email protected] <[email protected]>
Emne: Re: [crestron] CTI-P301
?

Thanks for the response Chris.
out of curiosity, what happens if you don¡¯t pass the course? Do I sit it again at my own expense??

I wasn¡¯t aware ppl sat the courses more than once?


Re: CTI-P301

 

Thanks for the response Chris.
out of curiosity, what happens if you don¡¯t pass the course? Do I sit it again at my own expense??

I wasn¡¯t aware ppl sat the courses more than once?


Re: CTI-P301

 

¿ªÔÆÌåÓý

I have taken 301 twice now. I think you should go through it. It will help your Simpl+ a lot, at least in my opinion. Though with online, not sure how the classes will be,but i enjoyed learning and gaining extra knowledge to help me. I know people who went through 201/301 2 or 3 times to get better.

Chris



Sent from my Verizon, Samsung Galaxy smartphone


-------- Original message --------
From: TJP <Ssute01@...>
Date: 4/10/20 6:39 AM (GMT-05:00)
Subject: [crestron] CTI-P301

Hey guys,
I recently passed my P301 entrance exam and have automatically been confirmed for the course (online) in about 2 and a half weeks time.?
My concern is, I¡¯m really not sure if I¡¯m ready for it.
My Simpl+ knowledge is pretty poor.

I¡¯m in 2 minds whether I should cancel and do it at a later date (once I¡¯ve had more Simpl+ experience/practice) or go through with it and hopefully I can keep up.
What do you think I should do?
Any advice would be appreciated?
Thanks


CTI-P301

 

Hey guys,
I recently passed my P301 entrance exam and have automatically been confirmed for the course (online) in about 2 and a half weeks time.?
My concern is, I¡¯m really not sure if I¡¯m ready for it.
My Simpl+ knowledge is pretty poor.

I¡¯m in 2 minds whether I should cancel and do it at a later date (once I¡¯ve had more Simpl+ experience/practice) or go through with it and hopefully I can keep up.
What do you think I should do?
Any advice would be appreciated?
Thanks


Re: Web-based local temperature

 

¿ªÔÆÌåÓý

If you are DYIer: Arduino Yun with DHT11 temp & hum sensor. Super cheap en very reliable.?

On 9 Apr 2020, at 23:24, ckangis <chris@...> wrote:

Hi All,
Anyone know of a *simple* way to harvest the Local area outdoor temperature from the web, into SMW to then put it on TSWs and TStats?? I'm looking for an alternative to the CHV-RSS because of cost, and what a pain it is to install them generally for this purpose...
TIA!!

(I'd get it from Crestron's SmartGraphics weather app, but they havent updated it for basic features...I only started asking for that 9 years ago...they could update it, I'm sure...:(? ?)


Re: Lutron QS

 

I know this seems too simple to actually be the cause, but in the Lutron module's I've opened up, they use "login:" (all lower-case) to trigger sending the password. If you're actually receiving "LOGIN:" (all caps) it won't work. However, the module could easily be modified to fix that.

Which exact version of the Lutron module are you using?

--- On Thursday, April 9, 2020 at 11:13 PM, AVMaster wrote:

Ok...so let me attempt to be more specific cause this is really weird.

Everything seems to be connecting just fine, if you view the TX$ and RX$ to and
from the TCP client in debugger you can see the module connect and the Lutron
processor responds with ¡®LOGIN:¡¯...it would be at that point I would expect the
TX$ from the module to respond with the username entered in the core module but
nothing happens...it just times out and responds with something like ¡®failed to
receive expected response¡¯ or something along those lines. I¡¯ve done this a
dozen times before but obviously something is wrong...

The real bummer about all this nonsense is that I only need to control just a
few loads in a theater and a golf simulator, not even doing any extensive
integration.


Re: Lutron QS

 

Ok...so let me attempt to be more specific cause this is really weird.

Everything seems to be connecting just fine, if you view the TX$ and RX$ to and from the TCP client in debugger you can see the module connect and the Lutron processor responds with ¡®LOGIN:¡¯...it would be at that point I would expect the TX$ from the module to respond with the username entered in the core module but nothing happens...it just times out and responds with something like ¡®failed to receive expected response¡¯ or something along those lines. ?I¡¯ve done this a dozen times before but obviously something is wrong...

The real bummer about all this nonsense is that I only need to control just a few loads in a theater and a golf simulator, not even doing any extensive integration.


Re: Matrix Analog vs DM Tool

 

¿ªÔÆÌåÓý

In parallel ¨C out of an abundance of caution I won¡¯t post the detail from the SIMPL Windows Help here but compare and contrast the descriptions of the SBUF and ABUF relative to enable being high.

?

The ABUF propagates on transition of enable to high or when a new value on the left side arrives that does not match the value on the right side.

The SBUF propagates on any value change but not a transition of enable to high.

?

The SBUF/ABUF naming is one of those weird quirks of Crestron that has persisted since the beginning of time or thereabouts.

?

If you aren¡¯t using the enable on the ABUF and want all values to propagate you could also use just the SBUF instead. ?

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] <[email protected]> On Behalf Of AV_Programmer via groups.io
Sent: Thursday, April 9, 2020 7:26 PM
To: [email protected]
Subject: Re: [crestron] Matrix Analog vs DM Tool

?

Lincoln -?

You nailed the explanation as that is exactly what I am doing. ?Are you saying running a SBUF parallel or in-line with the ABUF to fix this issue?

Also, can you share what are the benefits at times and what are the issues for using solely?an ABUF?

Thanks in advanced!

AV_Programmer


Incremental FW Update?

 

Inherited a job that needs a few programming additions including some S#. Luckily the previous integrator was kind enough to leave the PGM archive on the processor.?


question is the Pro3 is on a pretty old FW 1.009.xxx
i haven¡¯t upgraded a processor from that far back before. Wondering if anyone has had issues upgrading from old FW like that straight to current ?


Thanks!


Re: Lutron QS

 

One other thing to note is that newer QS versions require a crazy complex password like Cr3st0n!


Re: Matrix Analog vs DM Tool

 

Lincoln -?

You nailed the explanation as that is exactly what I am doing. ?Are you saying running a SBUF parallel or in-line with the ABUF to fix this issue?

Also, can you share what are the benefits at times and what are the issues for using solely?an ABUF?

Thanks in advanced!

AV_Programmer


CIPCommandprocessor.exe fails

 

Anyone ever seen these errors before?? I'm wondering if this processor was compromised.? I had port 41794 open when I first started seeing these errors and afterward found out about the CIP vulnerabilities.? Now, I have closed 41794 on the router, but still have issues with the processor locking up.? A reboot will get things working again.

?

13. Exception 'Data Abort' (0x4): Thread-Id=0cf1308a(pth=c0db2588), Proc-Id=09f0003e(pprc=c08f6c68) 'CIPCommandProcessor.exe', VM-active=09f0003e(pprc=c08f6c68) 'CIPCommandProcessor.exe'
?14. PC=4109b938(mscoree3_5.dll+0x0009b938) RA=4109be24(mscoree3_5.dll+0x0009be24) SP=030ff920, BVA=f9018bf4
?15. Error: nk.exe # 2020-04-09 14:56:49? # WDG: CIPCommandProcessor shutting down unexpectedly. Do Not Start=0
?16. Notice: CIPCommandProcessor.exe # 2020-04-09 14:56:53? # CresStore: Connections OK to redis
?
?17. Error: TLDM.exe # 2020-04-09 14:56:54? #? Ethernet Stack Application has already been registered
?18. Error: CIPCommandProcessor.exe # 2020-04-09 14:56:54? # SendTLDMAppRegisterMessage:Unable to Register with TLDM. Error code 0x1
?19. Error: CIPCommandProcessor.exe # 2020-04-09 14:56:54? #? Unable to register application with the TLDM

?20. Info: CIPCommandProcessor.exe # 2020-04-09 14:56:54? # Got Router connected event
?21. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:IPT. May not work correctly
?22. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:GETIPTABLE. May not work correctly
?23. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:SENDIPTABLE. May not work correctly
?24. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:WHO. May not work correctly
?25. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:TCPKEEPALIVE. May not work correctly
?26. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:EDEBUG. May not work correctly
?27. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:LISTENSTAT. May not work correctly
?28. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:HEARTBEAT. May not work correctly
?29. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:NUMNOHBRESP. May not work correctly
?30. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:ADDPO. May not work correctly
?31. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:REMPO. May not work correctly
?32. Notice: CIPCommandProcessor.exe # 2020-04-09 14:56:54? # Link established on CS
?33. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:SHOWPORTMAP. May not work correctly
?34. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:ISOLATENET. May not work correctly
?35. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:RESERVEDL. May not work correctly
?36. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:DHCPL. May not work correctly
?37. Notice: TLDM.exe # 2020-04-09 14:56:54? #? Event rcvd is 8
?38. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:CSROUT. May not work correctly
?39. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:CSINA. May not work correctly
?40. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:54? # Command already exists:NATENA. May not work correctly
?41. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SETCSAUTHENTICATION. May not work correctly
?42. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:CLEARCSAUTHENTICATION. May not work correctly
?43. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:GETCODE. May not work correctly
?44. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:BACNETADAPTER. May not work correctly
?45. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SOCKETS. May not work correctly
?46. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SECUREG. May not work correctly
?47. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:OCSP. May not work correctly
?48. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ETHW. May not work correctly
?49. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:EWDGCONFIG. May not work correctly
?50. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ADDM. May not work correctly
?51. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:REMM. May not work correctly
?52. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:MIPT. May not work correctly
?53. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ADDP. May not work correctly
?54. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:REMP. May not work correctly
?55. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTORESTAT. May not work correctly
?56. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTOREIMPOR. May not work correctly
?57. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTOREEXPORT. May not work correctly
?58. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:DATASTOREDEL. May not work correctly
?59. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ICMP. May not work correctly
?60. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:ICMPREDIRECT. May not work correctly
?61. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:CERTIF. May not work correctly
?62. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XAU. May not work correctly
?63. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XVAL. May not work correctly
?64. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XMET. May not work correctly
?65. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XDOM. May not work correctly
?66. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XUSER. May not work correctly
?67. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XPAS. May not work correctly
?68. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XTRUS. May not work correctly
?69. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:8021XSEN. May not work correctly
?70. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:TESTDNS. May not work correctly
?71. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:AUTODIS. May not work correctly
?72. Warning: ConsoleServiceCE.exe # 2020-04-09 14:56:55? # Command already exists:SERIALNUMBER. May not work correctly


Re: Matrix Analog vs DM Tool

 

¿ªÔÆÌåÓý

You need to look at the signal path from the button press to the DM analog input and the propagation characteristics of each signal along the way.

?

Also how are you triggering the ENTER on the DM frame?

?

If you had an INIT connected directly to the DM analog the INIT should repropagate through to the DM frame and all Bueno when the button is pressed.

?

On the other hand, if you have analog buffer or crosspoint between the INIT and the switcher this is the expected behavior because those only propagate values that have changed from the left to right ¨C eg if the left side is 1 and the right side is 1 the right side will never see a change no mantter how many times you init the left side ¨C this can be very handy in a lot of cases but cause trouble in others. There are solutions like running a serial buffer instead of or in parallel with the ABUF, using XSIG symbols to encapsulate the analog value into a serial before routing it through a crosspoint, etc. but thos all have varying considerations as far as processor workload, ease of maintenance of the program, etc.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Platinum)
ControlWorks Consulting, LLC |
D: (+1)440.771.4807 | O: (+1)440.449.1100? | F: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of AV_Programmer via groups.io
Sent: Thursday, April 09, 2020 5:55 PM
To: [email protected]
Subject: [crestron] Matrix Analog vs DM Tool

?

Folks -?

When routing analogs with a touch panel to a Matrix everything works great. When I use both DM Tool + Touch Panel things go weird.

If laptop is analog 1, and I press laptop on the touch panel, it routes. When I manually then use DM Tools to switch to input 2, when I press laptop on the touch panel again, it does not route. I have to route away from analog 1 (different source) then back to laptop, then it takes.

Is this an issue where, even though I manually switch using DM Tools, if the analog value already propagated in SIMPL (laptop 1), sending the same value again will not repropagate and make the switch on the touch panel?

Any information would be greatly appreciated.

AV_Programmer