Date

CHV-TSTAT force "extended" run times?

 

So my house has started running "cool" cycles for the year and I'm noticing that the cycle times seem much shorter and more frequently than prior years and actually if I look at the temps the temp is 1-2 degrees above the setpoint within a few seconds of the cool cycle ending. (I can't say I've ever noticed that before - but cycle times haven't bothered me before either)

The TSTAT is admittedly not in a great place -- it's where the HVAC contractor/prior owner put the old school Honeywell stat - but since all of the other walls on this floor are either exterior, a common wall with my next door neighbor, or have a fireplace/plasma on them I can't really do much better. (Also: Whomever designed the HVAC system was, IMO, smoking crack - there's only one return in the house and it's on the first floor of a 3-story townhome)

Is there any way to force the TSTAT to make the cool call longer / reduce the number of cycles? I'd much rather a longer cool cycle and have it overshoot the setpoint by a degree or five than have it firing every 10 minutes or so.

Or am I barking up the wrong tree in the first place?

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
Crestron Services Provider


Re: TV One 1T-SX-644 HDMI Switcher

 

FYI. One thing that got me on my last tvone job is that the IP had been set to "on" and that killed the com port. I think if it set to "auto" or "off" the com port works without issue.

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

--- In Crestron@..., "Chip" <cfm@> wrote:

If it's like any of the other TVOne horribleness, pressing buttons on the unit itself should generate strings that appear coming in to your com port. Other dreck I've worked with from these folks (IIRC) have been 57k 8N1, just pins 2, 3 & 5.

- Chip
This ^^^ is the super Chip tip of the day!!! I was working with a 1T-C2-750 and couldn't get the strings right. Just push the button you want to push, take the string it spits out, change the beginning F44 to a F04 and put a ?? in the checksum and you are good!


Re: S+ Parsing

Eric Williams
 

Can anyone recommend a thread or example s plus module that shows API XML polling and parsing. Few web servers I want to make modules for that use http requests and return XML.

Sent from my pocket robot!

-----Original Message-----
From: "Chip" <cfm@...>
Sent: ?5/?9/?2013 10:53 PM
To: "Crestron@..." <Crestron@...>
Subject: [Crestron] Re: S+ Parsing



No documentation outside of what's here on the forum, but there's also not a lot to it.

WHILE(1)

Says, take the code enclosed in the following curly braces and run it OVER AND OVER AGAIN - FOREVERRRRRRRR!

In most circumstances that classifies as A Very Bad Thing (tm). But if you include code inside the curly braces that returns time to the OS and the host SIMPL program, you're good. As luck would have, it:

GATHER(delimiter,src_string)

Says STOP right there, and keep monitoring "src_string". Do not pass GO, do not collect $200 UNTIL you see the specified "delimiter" appear in src_string. When you do, remove everything from the front of src_sting up to the first occurrence of delimiter, and put it in the variable I specify. Then go back to monitoring "src_string".

The great thing about GATHER is that as soon as it evaluates src_string and doesn't find delimiter, it returns control to the processor. The OS lets GATHER know when (if ever) delimiter arrives, and tells it go resume business.

The big trick is in your parsing code. You need to make sure you evaluate what GATHER returns to you as quickly as possible and let the code return to the GATHER. This is an exercise left to the reader, as how to parse everything depends entirely on the data you're expecting.

In theory, the only way I know of for your BUFFER_INPUT to overrun is if lots of data comes in that never contains the delimiter, or if your processor is SO bogged down otherwise that the OS can't get your S+ code fired back up to run the parsing code.

(Oddly enough, I have random instances of this happening at a job site right now. REALLY frustrating)

That said, I'm not sure I'd use this approach for JSON data, considering how sucky it's structured. Maybe there's a good way of doing it - I just haven't considered it...

- Chip

--- In Crestron@..., "redquartznow" <redquartznq@...> wrote:

Hello

I would like to have a clear definition of the hows and why's of

Main()
{
While (1)
{
Gather ();
Parse
}}

From my searching on this group I have found many tidbits of information
that make this seem to be an attractive solution to chatty devices. However every time I have used it (only on a project that sends back LARGE amounts of json data i.e. tv program guide for a week) i just seem to get buffer overruns.

Does anyone have a link to somewhere this has been explained in detail before?

Cheers,
Kurt


Re: Samsung UE55ES7000 - EX-Link

cyberbri24
 

My model is actually the UN65D8000X but I would hope input would be the same, not?

--- In Crestron@..., "cyberbri24" <cyberbri24@...> wrote:

The generic CEC mod does not switch inputs on the Samsung. I really need it to do that. I was told it needs to defualt to HDMI input as people keep playing the damn input buttons so when they next crew operates the system the input on the display isnt correct. I really was trying to avoid using an IR emitter since I confirmed power on/off using the CEC control. Any ideas would be welcome.

Thanks,
cyberbri

--- In Crestron@..., "Kol Johnson" <kol.mstc@> wrote:

not at all. I expect that the thing to do is to embrace CEC. There is a
device I just learned about that is basically an IP/serial to CEC converter.
Probably a good thing.

<>
HdmiCecUsb.html


don't know how well it works, but it seems that CEC is probably going to be
the only reliable, non-ir, control moving forward.


_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of grumpy_cake
Sent: Thursday, May 02, 2013 2:42 PM
To: Crestron@...
Subject: [Crestron] Re: Samsung UE55ES7000 - EX-Link




Is it bad of me to say that I am pleased to hear that I am not the only one
smashing my face into a wall?

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> , "Kol
Johnson" <kol.mstc@> wrote:

I have just wasted over an hour or so trying everything I can find on a
UN19D4003 with the same results. Different protocols, different baud
115200
down to 4800, no luck with any of them. I can see a response from the TV
in viewport but nothing I would expect, and it is the same response
regardless of the character sent. Sorry I cannot help.


_____

From: Crestron@... <mailto:Crestron%40yahoogroups.com>
[mailto:Crestron@... <mailto:Crestron%40yahoogroups.com> ] On
Behalf
Of grumpy_cake
Sent: Thursday, May 02, 2013 1:37 PM
To: Crestron@... <mailto:Crestron%40yahoogroups.com>
Subject: [Crestron] Re: Samsung UE55ES7000 - EX-Link




I see it go out in debugger, the TV does nothing, and Rx$ is still silent.

--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> , "Kol
Johnson" <kol.mstc@> wrote:

this is power toggle, make sure the TV is on, send it right out
Samsung_TX$
in debugger
"&#92;x08&#92;x22&#92;x00&#92;x00&#92;x00&#92;x00&#92;xD6"


_____

From: Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
[mailto:Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ] On
Behalf
Of grumpy_cake
Sent: Thursday, May 02, 2013 9:11 AM
To: Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
Subject: [Crestron] Re: Samsung UE55ES7000 - EX-Link




At the moment I am using the program that is in the folder with the
module
from:


ed_partner_modules/default.asp?manufacturer_id=134

samsung_un55es8000_v1_0_demo

I've changed nothing so would expect it to be set up correctly.

I can send commands using Toolbox but nothing happens and I get no
feedback
from the com port.

The module offers lots of sends and feedback.

Maybe I should try the UN55ES7500 instead.

--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"cyberbri24" <cyberbri24@> wrote:

Are you just using the generic CEC mod? I just programmed a UN65Dxxxx
and
the Exlink didn;t offer any menu options to turn on so I am only using
the
Power on and off commands which works only.

--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"grumpy_cake" <crestron@> wrote:

I've gone back to square 1 here to try and get this working.

I've got rid of my program and am just using the one supplied with
the
module.

I've uploaded it to my QM-RMC. (Was using an AV2)

I made the cable myself, pins 2,3,5 -> T,R,S tested it with a mm
several
times to be sure.

I've also tried changing the baud rate to 115200 as previously
suggested. It's now back on 9600.

I think the key thing here is that I am getting absolutely nothing
coming into SIMPL Debugger on the Rx$ of the com port that the Ex-Link
is
connected to.

The TV should be spurting something out regardless of what I am
sending
it no?



--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"LENREX" <lenrex@> wrote:

If you downloaded the UN55ES8000 module from the website. It's a
straight through cable.

Did you load BOTH the Hardware & Logic modules into your program?

Did you make your own cable, or use a Samsung cable?

I used the UN55ES8000 module on a 46" with a Samsung cable plugged
straight into a MC3 and it worked perfectly. ...wasn't a long run.

--- In Crestron@...
<mailto:Crestron%40yahoogroups.com> <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"grumpy_cake" <crestron@> wrote:

Thanks,

But does this actually apply to me? The pdf regarding the module
I
am using has no mention of injecting power...

I am connecting directly from an AV2 to the EX-Link port.

Have I missed something here? When others connect Ex-Link do you
not
connect directly?



--- In Crestron@...
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> <mailto:Crestron%40yahoogroups.com>
, "javimanga" <javimanga@> wrote:




Hi!

Check this info about ex-link

rs

Specially this!!!:

"As the TV uses 3.3V TTL levels, the serial input/output has
to
be
converted to/from TTL levels to RS232 levels (~10-15V). Thus a level
shifter
is needed. But most computers today, doesn't have an RS232 port, so you
also
need a USB-to-RS232 serial adapter (cable). Thus its a definite
advantage
to
buy a pre-fabricated USB-to-serial converter using 3.3 Volt TTL levels
on
the serial side. Common one to look for are based on the PL2303 and FTDI
chips.
WARNING! RS232 levels are up to 15V, which can cause seriously
damage at your TV!"

Regards,
Javier VM

--- In Crestron@...
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> , "grumpy_cake" <crestron@> wrote:

Hi,

I hope someone can have some patience and spoon feed me
through
this as I have sat here for hours and have got nowhere. I am guessing a
bit
so please let me know if I am doing something stupid.

Firstly this may all be down to me using a module that may
not
work as I can't find my TV.

I have a: UE55ES7000
Closest I can find is the UN55ES8000

I've made up a cable for EX-LINK control using the diagram
in
the module pdf

(integrated_partner_modules/help_files/959/samsung_un55es8000_v1_0_help.pdf)

Tested cable with multi-meter, seems fine.

I have set the value of the RS232 mode to Debug.

Tried a basic test with the module set up like this:



I'm getting nothing in debugger on Samsung_Rx$ and the TV
responds to nothing.

Any help appreciated.

Thanks.






[Non-text portions of this message have been removed]






[Non-text portions of this message have been removed]






[Non-text portions of this message have been removed]


Re: Samsung UE55ES7000 - EX-Link

cyberbri24
 

The generic CEC mod does not switch inputs on the Samsung. I really need it to do that. I was told it needs to defualt to HDMI input as people keep playing the damn input buttons so when they next crew operates the system the input on the display isnt correct. I really was trying to avoid using an IR emitter since I confirmed power on/off using the CEC control. Any ideas would be welcome.

Thanks,
cyberbri

--- In Crestron@..., "Kol Johnson" <kol.mstc@...> wrote:

not at all. I expect that the thing to do is to embrace CEC. There is a
device I just learned about that is basically an IP/serial to CEC converter.
Probably a good thing.

<>
HdmiCecUsb.html


don't know how well it works, but it seems that CEC is probably going to be
the only reliable, non-ir, control moving forward.


_____

From: Crestron@... [mailto:Crestron@...] On Behalf
Of grumpy_cake
Sent: Thursday, May 02, 2013 2:42 PM
To: Crestron@...
Subject: [Crestron] Re: Samsung UE55ES7000 - EX-Link




Is it bad of me to say that I am pleased to hear that I am not the only one
smashing my face into a wall?

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> , "Kol
Johnson" <kol.mstc@> wrote:

I have just wasted over an hour or so trying everything I can find on a
UN19D4003 with the same results. Different protocols, different baud
115200
down to 4800, no luck with any of them. I can see a response from the TV
in viewport but nothing I would expect, and it is the same response
regardless of the character sent. Sorry I cannot help.


_____

From: Crestron@... <mailto:Crestron%40yahoogroups.com>
[mailto:Crestron@... <mailto:Crestron%40yahoogroups.com> ] On
Behalf
Of grumpy_cake
Sent: Thursday, May 02, 2013 1:37 PM
To: Crestron@... <mailto:Crestron%40yahoogroups.com>
Subject: [Crestron] Re: Samsung UE55ES7000 - EX-Link




I see it go out in debugger, the TV does nothing, and Rx$ is still silent.

--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> , "Kol
Johnson" <kol.mstc@> wrote:

this is power toggle, make sure the TV is on, send it right out
Samsung_TX$
in debugger
"&#92;x08&#92;x22&#92;x00&#92;x00&#92;x00&#92;x00&#92;xD6"


_____

From: Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
[mailto:Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ] On
Behalf
Of grumpy_cake
Sent: Thursday, May 02, 2013 9:11 AM
To: Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
Subject: [Crestron] Re: Samsung UE55ES7000 - EX-Link




At the moment I am using the program that is in the folder with the
module
from:


ed_partner_modules/default.asp?manufacturer_id=134

samsung_un55es8000_v1_0_demo

I've changed nothing so would expect it to be set up correctly.

I can send commands using Toolbox but nothing happens and I get no
feedback
from the com port.

The module offers lots of sends and feedback.

Maybe I should try the UN55ES7500 instead.

--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"cyberbri24" <cyberbri24@> wrote:

Are you just using the generic CEC mod? I just programmed a UN65Dxxxx
and
the Exlink didn;t offer any menu options to turn on so I am only using
the
Power on and off commands which works only.

--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"grumpy_cake" <crestron@> wrote:

I've gone back to square 1 here to try and get this working.

I've got rid of my program and am just using the one supplied with
the
module.

I've uploaded it to my QM-RMC. (Was using an AV2)

I made the cable myself, pins 2,3,5 -> T,R,S tested it with a mm
several
times to be sure.

I've also tried changing the baud rate to 115200 as previously
suggested. It's now back on 9600.

I think the key thing here is that I am getting absolutely nothing
coming into SIMPL Debugger on the Rx$ of the com port that the Ex-Link
is
connected to.

The TV should be spurting something out regardless of what I am
sending
it no?



--- In Crestron@... <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"LENREX" <lenrex@> wrote:

If you downloaded the UN55ES8000 module from the website. It's a
straight through cable.

Did you load BOTH the Hardware & Logic modules into your program?

Did you make your own cable, or use a Samsung cable?

I used the UN55ES8000 module on a 46" with a Samsung cable plugged
straight into a MC3 and it worked perfectly. ...wasn't a long run.

--- In Crestron@...
<mailto:Crestron%40yahoogroups.com> <mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> ,
"grumpy_cake" <crestron@> wrote:

Thanks,

But does this actually apply to me? The pdf regarding the module
I
am using has no mention of injecting power...

I am connecting directly from an AV2 to the EX-Link port.

Have I missed something here? When others connect Ex-Link do you
not
connect directly?



--- In Crestron@...
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> <mailto:Crestron%40yahoogroups.com>
, "javimanga" <javimanga@> wrote:




Hi!

Check this info about ex-link

rs

Specially this!!!:

"As the TV uses 3.3V TTL levels, the serial input/output has
to
be
converted to/from TTL levels to RS232 levels (~10-15V). Thus a level
shifter
is needed. But most computers today, doesn't have an RS232 port, so you
also
need a USB-to-RS232 serial adapter (cable). Thus its a definite
advantage
to
buy a pre-fabricated USB-to-serial converter using 3.3 Volt TTL levels
on
the serial side. Common one to look for are based on the PL2303 and FTDI
chips.
WARNING! RS232 levels are up to 15V, which can cause seriously
damage at your TV!"

Regards,
Javier VM

--- In Crestron@...
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com>
<mailto:Crestron%40yahoogroups.com> , "grumpy_cake" <crestron@> wrote:

Hi,

I hope someone can have some patience and spoon feed me
through
this as I have sat here for hours and have got nowhere. I am guessing a
bit
so please let me know if I am doing something stupid.

Firstly this may all be down to me using a module that may
not
work as I can't find my TV.

I have a: UE55ES7000
Closest I can find is the UN55ES8000

I've made up a cable for EX-LINK control using the diagram
in
the module pdf

(integrated_partner_modules/help_files/959/samsung_un55es8000_v1_0_help.pdf)

Tested cable with multi-meter, seems fine.

I have set the value of the RS232 mode to Debug.

Tried a basic test with the module set up like this:



I'm getting nothing in debugger on Samsung_Rx$ and the TV
responds to nothing.

Any help appreciated.

Thanks.






[Non-text portions of this message have been removed]






[Non-text portions of this message have been removed]






[Non-text portions of this message have been removed]


Re: Activity Detection

 

It was the Page Join Transmit.....always the little things

Thanks

--- In Crestron@..., Lincoln King-Cliby <lincoln@...> wrote:

And on that note, if you don't need the page join feedback you can turn off Page Join Feedback Transmission (without connecting to a panel PAGEJOINXMIT ?) -- I'd say that's certainly not helping because the processor sees it as inbound data from the panel and thus "activity"

Lincoln

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
V: 440.449.1100 x1107 | F: 440.449.1106 | I:
Crestron Services Provider


-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of Jay Basen
Sent: Friday, May 10, 2013 2:27 PM
To: Crestron@...
Subject: Re: [Crestron] Activity Detection

I expect this may be due to page joins transmitting back from the touch panel to the processor.

Hope this helps

Jay

----- Original Message -----

From: "Gregg M" <jets_in_2003@...>
To: Crestron@...
Sent: Friday, May 10, 2013 9:23:58 AM
Subject: [Crestron] Activity Detection





So I have a small piece of code running in my MC3 that basically says if my TPS-4L Activity Detection goes Low Set the hard button Backlight to Low and Jump to Page X. From my understanding Activity Detection is based on anything from the touch panel to the processor, not the other way around. But in my case here, when the processor triggers the page flip, it also registers that as activity, thus trigger the backlights to go high and the timer to restart.

Am I incorrect in my assumption or am I just plain doing something wrong.









------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: Activity Detection

 

or what you could do, don't use the activity detection and connect all you
digital join press to an or gate, attach the or gate to a ros trig. attach
the ros out to an os gate [trig*] ( put a 0 on the trig) and the os out
trig the action you want to do.




{Paf}


2013/5/10 Lincoln King-Cliby <lincoln@...>

**


And on that note, if you don't need the page join feedback you can turn
off Page Join Feedback Transmission (without connecting to a panel
PAGEJOINXMIT ?) -- I'd say that's certainly not helping because the
processor sees it as inbound data from the panel and thus "activity"

Lincoln

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
V: 440.449.1100 x1107 | F: 440.449.1106 | I:
Crestron Services Provider


-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On
Behalf Of Jay Basen
Sent: Friday, May 10, 2013 2:27 PM
To: Crestron@...
Subject: Re: [Crestron] Activity Detection

I expect this may be due to page joins transmitting back from the touch
panel to the processor.

Hope this helps

Jay

----- Original Message -----

From: "Gregg M" <jets_in_2003@...>
To: Crestron@...
Sent: Friday, May 10, 2013 9:23:58 AM
Subject: [Crestron] Activity Detection

So I have a small piece of code running in my MC3 that basically says if
my TPS-4L Activity Detection goes Low Set the hard button Backlight to Low
and Jump to Page X. From my understanding Activity Detection is based on
anything from the touch panel to the processor, not the other way around.
But in my case here, when the processor triggers the page flip, it also
registers that as activity, thus trigger the backlights to go high and the
timer to restart.

Am I incorrect in my assumption or am I just plain doing something wrong.

[Non-text portions of this message have been removed]

------------------------------------





Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links



[Non-text portions of this message have been removed]


Re: Activity Detection

 

And on that note, if you don't need the page join feedback you can turn off Page Join Feedback Transmission (without connecting to a panel PAGEJOINXMIT ?) -- I'd say that's certainly not helping because the processor sees it as inbound data from the panel and thus "activity"

Lincoln

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
V: 440.449.1100 x1107 | F: 440.449.1106 | I:
Crestron Services Provider

-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of Jay Basen
Sent: Friday, May 10, 2013 2:27 PM
To: Crestron@...
Subject: Re: [Crestron] Activity Detection

I expect this may be due to page joins transmitting back from the touch panel to the processor.

Hope this helps

Jay

----- Original Message -----

From: "Gregg M" <jets_in_2003@...>
To: Crestron@...
Sent: Friday, May 10, 2013 9:23:58 AM
Subject: [Crestron] Activity Detection





So I have a small piece of code running in my MC3 that basically says if my TPS-4L Activity Detection goes Low Set the hard button Backlight to Low and Jump to Page X. From my understanding Activity Detection is based on anything from the touch panel to the processor, not the other way around. But in my case here, when the processor triggers the page flip, it also registers that as activity, thus trigger the backlights to go high and the timer to restart.

Am I incorrect in my assumption or am I just plain doing something wrong.









------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: AV2 rebooting continously after program upload

 

I also have an ancient Pro2 (IIRC, when I got it was running CUZ 1.00x) with 32MB of RAM running the latest release (it might actually be newer than latest -- I need to double check) and no issues.

75% of the Pro2s in our Cleveland office are 32MB versions -- again all running the latest released FW -- and they take all the beatings we throw at them.

Yes, if the program is huge you may have issues but it's not a safe blanket statement, and if everything's been happy and no major changes have been introduced it's almost certainly not the issue.

Lincoln

--
Lincoln King-Cliby, CTS
Sr. Systems Architect | Crestron Certified Master Programmer (Silver)
ControlWorks Consulting, LLC
V: 440.449.1100 x1107 | F: 440.449.1106 | I:
Crestron Services Provider

-----Original Message-----
From: Crestron@... [mailto:Crestron@...] On Behalf Of Tray Schaeffer
Sent: Friday, May 10, 2013 2:44 PM
To: Crestron@...
Subject: Re: [Crestron] Re: AV2 rebooting continously after program upload

Same here, Chip.

I have a rather old PRO2 with the smaller memory and 4.7 firmware runs just fine.

Tray


From: Chip
Sent: Friday, May 10, 2013 1:35 PM
To: Crestron@...
Subject: [Crestron] Re: AV2 rebooting continously after program upload



???

I've got one of the first ever Pro2s on my bench running 4.7.4 without any problems. Are you sure about that??

- Chip

--- In mailto:Crestron%40yahoogroups.com, "Jason Santlofer" <jason@...> wrote:

Check the amont of onboard memory. If its 32 the unit is old and the
firmware needs to be downgraded if you are running something current or it
needs to be sent to crestron for a memory upgrade. I think its about 200$
or so.





[Non-text portions of this message have been removed]



------------------------------------



Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the Database area.
Yahoo! Groups Links


Re: AV2 rebooting continously after program upload

 

Same here, Chip.

I have a rather old PRO2 with the smaller memory and 4.7 firmware runs just fine.

Tray


From: Chip
Sent: Friday, May 10, 2013 1:35 PM
To: Crestron@...
Subject: [Crestron] Re: AV2 rebooting continously after program upload



???

I've got one of the first ever Pro2s on my bench running 4.7.4 without any problems. Are you sure about that??

- Chip

--- In mailto:Crestron%40yahoogroups.com, "Jason Santlofer" <jason@...> wrote:

Check the amont of onboard memory. If its 32 the unit is old and the
firmware needs to be downgraded if you are running something current or it
needs to be sent to crestron for a memory upgrade. I think its about 200$
or so.





[Non-text portions of this message have been removed]


Re: Activity Detection

 

I expect this may be due to page joins transmitting back from the touch panel to the processor.

Hope this helps

Jay

----- Original Message -----

From: "Gregg M" <jets_in_2003@...>
To: Crestron@...
Sent: Friday, May 10, 2013 9:23:58 AM
Subject: [Crestron] Activity Detection





So I have a small piece of code running in my MC3 that basically says if my TPS-4L Activity Detection goes Low Set the hard button Backlight to Low and Jump to Page X. From my understanding Activity Detection is based on anything from the touch panel to the processor, not the other way around. But in my case here, when the processor triggers the page flip, it also registers that as activity, thus trigger the backlights to go high and the timer to restart.

Am I incorrect in my assumption or am I just plain doing something wrong.





[Non-text portions of this message have been removed]


Re: Samsung UE55ES7000 - EX-Link

 

Did you get it to work?

I'm having the same issue

--
Sebastian Marszalek


Re: AV2 rebooting continously after program upload

Jason Santlofer
 

Yes. Totally dependant on program size. Might work with the program and as
you build on it and it gets larger will do the reboot thing. Same with AV2.



JMG Outlook Signature



From: Crestron@... [mailto:Crestron@...] On Behalf
Of Chip
Sent: Friday, May 10, 2013 1:36 PM
To: Crestron@...
Subject: [Crestron] Re: AV2 rebooting continously after program upload






???

I've got one of the first ever Pro2s on my bench running 4.7.4 without any
problems. Are you sure about that??

- Chip

--- In Crestron@... <mailto:Crestron%40yahoogroups.com> , "Jason
Santlofer" <jason@...> wrote:

Check the amont of onboard memory. If its 32 the unit is old and the
firmware needs to be downgraded if you are running something current or it
needs to be sent to crestron for a memory upgrade. I think its about 200$
or so.


Re: TV One 1T-SX-644 HDMI Switcher

 

More devices need to support setting the checksum to "??". The TVOne
protocol is a disaster, but that is one redeeming feature -- B&K receivers
also implement an optional checksum I believe.

On Fri, May 10, 2013 at 1:33 PM, jbudz1977 <jbudz1977@...> wrote:

--- In Crestron@..., "Chip" <cfm@...> wrote:

If it's like any of the other TVOne horribleness, pressing buttons on
the unit itself should generate strings that appear coming in to your com
port. Other dreck I've worked with from these folks (IIRC) have been 57k
8N1, just pins 2, 3 & 5.

- Chip
This ^^^ is the super Chip tip of the day!!! I was working with a
1T-C2-750 and couldn't get the strings right. Just push the button you
want to push, take the string it spits out, change the beginning F44 to a
F04 and put a ?? in the checksum and you are good!



------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links


--
Jeremy Weatherford


Re: Wireless RS-232

 

I have five of the WF2SLs installed for signage control, they work great.
Just keep in mind they need 802.11b, which is being phased out.

On Fri, May 10, 2013 at 10:31 AM, Joseph Vossen <jkv@...> wrote:

will this work for you?

<>

On May 10, 2013, at 10:19 AM, jpneflim wrote:

OT: Anyone have any experience using wireless RS-232 equipment.
I have some old Lutron Homeworks equipment that needs modification
routinely, but unfortunately, is not in the room where the lights are.
I would love to be able to modify light levels without having to run
back and forth from equipment room to living area.
Joe

------------------------------------




Check out the Files area for useful modules, documents, and drivers.

A contact list of Crestron dealers and programmers can be found in the
Database area.
Yahoo!
Groups Links


--
Jeremy Weatherford


Re: AV2 rebooting continously after program upload

Chip
 

???

I've got one of the first ever Pro2s on my bench running 4.7.4 without any problems. Are you sure about that??

- Chip

--- In Crestron@..., "Jason Santlofer" <jason@...> wrote:

Check the amont of onboard memory. If its 32 the unit is old and the
firmware needs to be downgraded if you are running something current or it
needs to be sent to crestron for a memory upgrade. I think its about 200$
or so.


Re: TV One 1T-SX-644 HDMI Switcher

 

--- In Crestron@..., "Chip" <cfm@...> wrote:

If it's like any of the other TVOne horribleness, pressing buttons on the unit itself should generate strings that appear coming in to your com port. Other dreck I've worked with from these folks (IIRC) have been 57k 8N1, just pins 2, 3 & 5.

- Chip
This ^^^ is the super Chip tip of the day!!! I was working with a 1T-C2-750 and couldn't get the strings right. Just push the button you want to push, take the string it spits out, change the beginning F44 to a F04 and put a ?? in the checksum and you are good!


Re: EX gateways offline

 

All those double'd up EX gateways, sure would be nice if they supported multiple IPID's eh?

--- In Crestron@..., Heath Volmer <hvolmer@...> wrote:

Have a CP3 with five EX gateways on it. Last night, all five of them went off line - in the sense that IPT shows offline but I can still console in. The CEN-TRACK also went with them. DM, SWAMPs and IDOC are fine. This has happened before. I reboot the gateways and they're fine.

Someone at Crestron told me that it might be related to autonegotiation settings interacting with the HP switch, but there are also the PAC2's EX gateways on the same switch and they aren't offline. In fact, I'm pretty confident that the PAC2's gateways have been entirely solid all along.

One of the five EX gateways is on a separate switch in a separate building where there is yet another EX gateway connected to a PAC2M. It has stayed alive. This tends to point me back to the processor misbehaving.

Thoughts?

Heath


Re: EX gateways offline

 

I had the same issue. Was given same answer by TB. Hard coded 100/full on
the switch for the MC3 and voila problem went away.

Nick

Sent from my eMail.

On May 10, 2013, at 10:33 AM, Heath Volmer <hvolmer@...> wrote:



Have a CP3 with five EX gateways on it. Last night, all five of them went
off line - in the sense that IPT shows offline but I can still console in.
The CEN-TRACK also went with them. DM, SWAMPs and IDOC are fine. This has
happened before. I reboot the gateways and they're fine.

Someone at Crestron told me that it might be related to autonegotiation
settings interacting with the HP switch, but there are also the PAC2's EX
gateways on the same switch and they aren't offline. In fact, I'm pretty
confident that the PAC2's gateways have been entirely solid all along.

One of the five EX gateways is on a separate switch in a separate building
where there is yet another EX gateway connected to a PAC2M. It has stayed
alive. This tends to point me back to the processor misbehaving.

Thoughts?

Heath




[Non-text portions of this message have been removed]


Re: Clearing 3-series processor

 

Initialize clears all but wipes out anything else you might have on the processor like mobile projects etc.

--- In Crestron@..., Chen Zhihao <bobbylken@...> wrote:

Hi all,

Anybody know of a way to clearing all the 10 program and IP table of a 3-series processor instead of doing it one by one in toolbox?

Thank you all.

cheers,
Ken
?
*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*
Learn to focus on solutions not on problems
"If you look at what you do not have in life, you don't have anything"
"If you look at what you have in life, you have everything"
*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*^*

[Non-text portions of this message have been removed]