¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io

Re: EX gateways offline


 

I had the same issue. Was given same answer by TB. Hard coded 100/full on
the switch for the MC3 and voila problem went away.

Nick

Sent from my eMail.

On May 10, 2013, at 10:33 AM, Heath Volmer <hvolmer@...> wrote:



Have a CP3 with five EX gateways on it. Last night, all five of them went
off line - in the sense that IPT shows offline but I can still console in.
The CEN-TRACK also went with them. DM, SWAMPs and IDOC are fine. This has
happened before. I reboot the gateways and they're fine.

Someone at Crestron told me that it might be related to autonegotiation
settings interacting with the HP switch, but there are also the PAC2's EX
gateways on the same switch and they aren't offline. In fact, I'm pretty
confident that the PAC2's gateways have been entirely solid all along.

One of the five EX gateways is on a separate switch in a separate building
where there is yet another EX gateway connected to a PAC2M. It has stayed
alive. This tends to point me back to the processor misbehaving.

Thoughts?

Heath




[Non-text portions of this message have been removed]

Join [email protected] to automatically receive all group messages.