TSW-750 Issues
jmgaudiovideo
Hi All,
Not not sure if this has been touched upon somewhere along the lines. I'm sure everyone has their stories about the new TSW-750 panels. I need some help. We have a couple of these systems in the field and both of them seem to have problems with the touchscreens just randomly freezing and falling off line. We have updated to just about every firmware Crestron has put out even some of the beta ones. We don't even have video running to the panels so I don't think it a memory issue. The only common denominator in the two systems is a Pakedge SW16-16PB ethernet switch which is powering the panels. It is a managed switch. On the larger job (10 tsw panels)the switch would actually freeze and need to be rebooted along with the CP3 processor to make them work again. On the other job the client says he just needs to reboot the panel to make them work. But he does so a couple times a day. We have gone through the channels at Crestron sent in code etc and they can't pinpoint a problem. I and our programmer have been working with Crestron product for quite a few years and never experienced these kind of problems before. Is anyone else experiencing these types of issues and if so were you able to solve them? My customers are increasingly losing faith in our ability to finish the job and honestly I am at a loss. |
Re: cant communicate with the system
Its set up as a CresNET slave device.
toggle quoted message
Show quoted text
You cannot upload a program to a slave device and it needs to be restored back to a master processor. Connect to the processor via serial cable and open the terminal window in toolbox (or Viewport if you have that installed) Type 'restore' and hit enter then confirm with yes... The processor will revert back to factory default and become a master processor. Note : any ip settings will have to be entered in again.. Cheers, Chris. --- In Crestron@..., "thabith" <thabithtippu@...> wrote:
|
Re: Wireless battery powered wall mounted keypad?
What about a Rako wireless keypad and a relay receiver module?
Regards, Nick Masterson [Description: ISI final logo] Home Automation Systems - Multi-room Audio Visual - Lighting Control - Shading Solutions - Security Systems - Data Networks 65 East Hill Wandsworth London SW18 2QE T: 020 8877 3399 F: 020 8877 9970 W: www.IntegratedSoundAndVision.co.uk<> Confidentiality: If you have received this email in error, please notify the sender. This e-mail and any attached files are intended only for the use of the person or organisation to whom they are addressed. The contents are confidential and maybe legally privileged (in other words, their unauthorised distribution may be unlawful). It is prohibited and may be unlawful to open, use or copy these documents or disclose them to anyone unless you are authorised to do so. |
Re: Samsung UE55ES7000 - EX-Link
Yep, back in UART mode, no dice.
toggle quoted message
Show quoted text
--- In Crestron@..., "Chip" <cfm@...> wrote:
|
Re: Samsung UE55ES7000 - EX-Link
Erm.... Maybe not....
toggle quoted message
Show quoted text
When it wasn't working I suddenly remembered reading something about putting it in debug mode but just realised that that was for SammyGo. (which I have not actually applied) Will switch it back.... --- In Crestron@..., "Chip" <cfm@...> wrote:
|
Re: Samsung UE55ES7000 - EX-Link
Hmmm.... The main reason I was doing this was to try and make it a bit more reliable than the IR!
toggle quoted message
Show quoted text
--- In Crestron@..., "Matt" <asmlw29@...> wrote:
|
Re: How would you parse this data?
Hi Matt,
toggle quoted message
Show quoted text
I'd lean towards a state machine as (personal opinion) I think they make for nice readable code, and easy to debug, with less repetition of "get this but, get the next bit, get the next bit..." where those hard-to-spot typos can creep in. It takes a bit more thinking time though (to plan the various states and transitions), so you have to decide if that's worthwhile effort, or a quick (and possible dirtier) solution is best. Like anything though - the more you do, the faster you get, and I'm very "pro" visual thinking, so I tend to sketch out a SM diagram on paper first. That makes implementing the solution almost automatic. Go on... State Machines rule... do it... ;-) ATB, Ol --- In Crestron@..., "matt_rasmussen_2000" <mjrtoo@...> wrote:
|
Internet Radio - Control Via Touchpanels
tomasogmor
Hi,
Am looking to find a solution to get Internet Radio (for multi-room audio) controlled from the room touchpanels. At Present we are using Rasberry Pi's running XBMC as the sources for the Crestron Multi-Room amps (2 x C2N-AMP-4x100) the Touchpanels range from TPS-4L's to TPMC-8X and a TSW-750. Running with a MC2E Processor. I have the Crestron XBMC Module Running and it's fine for browsing MP3's etc. in the Library. But I cannot get the touchanels to control any of the Radio add-ons. Is there any other way anyone can think of doing this, without have to purchase an Adagio system or something. It doesn't have to be XBMC, I just want the user to be able to pick On-Line radio stations from the ouchpanel. Thanks a mil, Tomas |
Re: Wireless battery powered wall mounted keypad?
Nice! I'm in the UK though, and the form factor is US, also voltage is 110 to 125.
toggle quoted message
Show quoted text
--- In Crestron@..., "Block-O-Matic" <michael@...> wrote:
|
Re: Wireless battery powered wall mounted keypad?
Good one - I've not heard of that - I like the idea of pulling the internals out and attaching to a nicer keypad.
toggle quoted message
Show quoted text
Didn't come up with anything on a quick google - have you got any details of the Crestron RF Hack for this?? --- In Crestron@..., "Kris" <kris.k@...> wrote:
|
cant communicate with the system
thabith
when i connect with crestron tool bo it shows the system with this error log .
System log: 1. Notice: System startup: CslaveAV2 Cntrl Eng [v4.007.0004 (Mar 05 2012), #0890237E] TimeStamp: 03:15:15 3-20-00 UpTime: 0 days 00:00:03.22 Task: IdleTask Total Errors Logged = 1 End of System log and i cant send program and vision pro design to module when i select it it shows message as the device does not support the required capabilities for the dialog to function . my system is AV2 . |
Re: Samsung UE55ES7000 - EX-Link
Matt
For what its worth, I eventually got EX-Link working, but it was flaky at best. I was only using it for power and switching, and it worked about 70-80% of the time.
toggle quoted message
Show quoted text
Since I was using DM products, I used the CEC codes and they are working great! --- In Crestron@..., Ray Jain <rjain@...> wrote:
|
Re: Samsung UE55ES7000 - EX-Link
Chip
Was "debug" called out somewhere in the docs? I don't believe you want that. I haven't worked with one in a while, so I don't remember what the other options are. "Uart" comes to mind...
toggle quoted message
Show quoted text
- Chip --- In Crestron@..., "grumpy_cake" <crestron@...> wrote:
|
Re: Samsung UE55ES7000 - EX-Link
Ray Jain
One thing about Samsung I have noticed is rs-232 or IR you have to first turn the TV on or off woth a remote to get control over the display.
toggle quoted message
Show quoted text
--------------------------------------- Ray Jain, Junior Programmer (832) 618-9672 rjain@...<mailto:rjain@...> SUMMIT INTEGRATION SYSTEMS On Apr 28, 2013, at 6:27 PM, "grumpy_cake" <crestron@...<mailto:crestron@...>> wrote:
Hi, I hope someone can have some patience and spoon feed me through this as I have sat here for hours and have got nowhere. I am guessing a bit so please let me know if I am doing something stupid. Firstly this may all be down to me using a module that may not work as I can't find my TV. I have a: UE55ES7000 Closest I can find is the UN55ES8000 I've made up a cable for EX-LINK control using the diagram in the module pdf (integrated_partner_modules/help_files/959/samsung_un55es8000_v1_0_help.pdf) Tested cable with multi-meter, seems fine. I have set the value of the RS232 mode to Debug. Tried a basic test with the module set up like this: I'm getting nothing in debugger on Samsung_Rx$ and the TV responds to nothing¡ Any help appreciated. Thanks. |
Re: Tesla Model S
bill_heil
Anyone take a crack at this? I am trying to figure out an approach here as well.
toggle quoted message
Show quoted text
--- In Crestron@..., "jared_shapiro@..." <shapirja@...> wrote:
|
Samsung UE55ES7000 - EX-Link
Hi,
I hope someone can have some patience and spoon feed me through this as I have sat here for hours and have got nowhere. I am guessing a bit so please let me know if I am doing something stupid. Firstly this may all be down to me using a module that may not work as I can't find my TV. I have a: UE55ES7000 Closest I can find is the UN55ES8000 I've made up a cable for EX-LINK control using the diagram in the module pdf (integrated_partner_modules/help_files/959/samsung_un55es8000_v1_0_help.pdf) Tested cable with multi-meter, seems fine. I have set the value of the RS232 mode to Debug. Tried a basic test with the module set up like this: I'm getting nothing in debugger on Samsung_Rx$ and the TV responds to nothing¡ Any help appreciated. Thanks. |
Re: Pleasant surprise with masterinstaller today.
Its Sunday, not many people online at Crestron :)
toggle quoted message
Show quoted text
--- In Crestron@..., "Easton" <easton.altree@...> wrote:
|
Pleasant surprise with masterinstaller today.
I opened MasterInstaller today to update a few things. I was shocked at how fast the downloads occurred. I had a D3 template file that was 285meg, Crestron Database 152meg, and Toolbox 67meg. All 3 were done downloading within 90 seconds. This is a significant departure from anything I've seen in the last 9 years of downloading from there.
|
Re: Discovery of idoc issue.
the IP in the table IP if from the Master processor (your system, for ex,
adagio) and the IP ID is the ID assigned to the CenIdoc in the program. If the adagio cant find the cen idoc, check if the adagio is in the same subnet (for ex. 192.168.0.100) _____ De: Crestron@... [mailto:Crestron@...] En nombre de jimathome80@... Enviado el: s¨¢bado, 27 de abril de 2013 14:28 Para: Crestron@... Asunto: [Crestron] Re: Discovery of idoc issue. I have now made a connection to the idoc via serial cable and then by using the toolbox device tree view and the correct com port. I then right click on the idoc device and select functions.... Where do I go from here to make this device discoverable via the composer wizard. If I select Ethernet addressing it shows IP address as 192.168.0.4 with dhcp not ticked. Or if I select ip table setup it shows me ... Ip Id 05. IP address 192.168.000.002 What and where do I need to enter this info I've gone back into the adagio composer and made the idoc ipid 05 as it originally said ip id 03 here then what should I do next? Thanks to anybody that can point me in the right direction --- In Crestron@... <mailto:Crestron%40yahoogroups.com> , "jimathome80@..." <jimathome80@...> wrote: pc to idoc and then using view port select the same connection that I originally used to find IP address of aads then I run the wizard but the next screen shows a yellow dot next to idoc saying that's its not discovered! Could the com port setting have changed on my pc? Bridges <gravityhammer@> wrote: manually idocusing the supplied serial cable. devicein adagio composer/system builder. thendiscovery wizard. I've set up ip communications between the aads and thecrestnet commutation with the tps4l on an I'd of 03 but it asks for wrong.serial number of idoc? Sorry in advance for the basic question... |
to navigate to use esc to dismiss