Re: Cisco SX80 not allowing more than one call

 

¿ªÔÆÌåÓý

Lincoln,

Thanks for the reply.
The crazy thing is that I¡¯m not getting an error.
I¡¯m also utilizing the hangup all calls.
It¡¯s like the codec is ignoring all new call commands.
The module stays connected and I can use camera controls or other features.
It¡¯s literally just trying to initiate a new call after hanging up from the previous.


Nate

On Jun 22, 2021, at 9:59 AM, Lincoln King-Cliby via groups.io <lincoln@...> wrote:

?

Can¡¯t say I have ¨C though most of my recent Cisco codecs have had the touch 10 as the only dialing control and using a Crestron processor (no TP) as an interface to lighting/shades/HVAC and AV automation) ¨C what error do you get back from the CLI when you try the 2nd call ?

?

Is it possible you aren¡¯t cleanly disconnecting the first call and if the codec isn¡¯t licensed for multipoint because it thinks it¡¯s still in a call it won¡¯t allow an additional call. If you issue the hang up all command before (not just ¡°hang up call 1¡±, etc.) that might help to clean the deck.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of Nate via groups.io
Sent: Tuesday, June 22, 2021 11:51 AM
To: [email protected]
Subject: [crestron] Cisco SX80 not allowing more than one call

?

Hello All,

Has anyone seen an issue with an SX80 only allowing you to make one call and then having to reboot it before you can dial/make another call from the Crestron panel?
You can still make calls using the touch 10 no problem.?
We have updated firmware on the codec as well as rolled it back to see if that was the issue.
I can't seem to find what the problem is.?

Nate


Re: Long copper run and NVX

 

¿ªÔÆÌåÓý

I believe one retrofit project I did the network design/configuration/commissioning for we had one run (Cat5-pre-E) with a cable run in the ¡°it might have actually been slightly longer than 300 ft/100 meter¡± range and the NVX device at the end of the cable (pretty sure it was a D30) has had no issues. I think that might have even been with PoE but I¡¯m a little foggy on the physical details since that was largely beyond my responsibility.

?

Over that distance I¡¯d be more concerned about PoE if you were going to try to use it, particularly PoE++/UPOE-type power consumption than data integrity, but since you mentioned having fiber I can assume you¡¯re planning on locally powering anyway.

?

Of course using a proper cable certifier to make sure the cable and terminations are completely happy with the world is always a good idea.

?

Lincoln

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of John Gabler
Sent: Tuesday, June 22, 2021 11:26 AM
To: [email protected]
Subject: [crestron] Long copper run and NVX

?

I have a run that will be about 275ft.? Shielded CAT6A connected to a 10G extreme switch.? I have a fiber there as well and will be prepared to use it.? But, just wondering if anyone has any feedback that has been in this situation.


Re: Cisco SX80 not allowing more than one call

 

¿ªÔÆÌåÓý

Can¡¯t say I have ¨C though most of my recent Cisco codecs have had the touch 10 as the only dialing control and using a Crestron processor (no TP) as an interface to lighting/shades/HVAC and AV automation) ¨C what error do you get back from the CLI when you try the 2nd call ?

?

Is it possible you aren¡¯t cleanly disconnecting the first call and if the codec isn¡¯t licensed for multipoint because it thinks it¡¯s still in a call it won¡¯t allow an additional call. If you issue the hang up all command before (not just ¡°hang up call 1¡±, etc.) that might help to clean the deck.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of Nate via groups.io
Sent: Tuesday, June 22, 2021 11:51 AM
To: [email protected]
Subject: [crestron] Cisco SX80 not allowing more than one call

?

Hello All,

Has anyone seen an issue with an SX80 only allowing you to make one call and then having to reboot it before you can dial/make another call from the Crestron panel?
You can still make calls using the touch 10 no problem.?
We have updated firmware on the codec as well as rolled it back to see if that was the issue.
I can't seem to find what the problem is.?

Nate


Cisco SX80 not allowing more than one call

 

Hello All,

Has anyone seen an issue with an SX80 only allowing you to make one call and then having to reboot it before you can dial/make another call from the Crestron panel?
You can still make calls using the touch 10 no problem.?
We have updated firmware on the codec as well as rolled it back to see if that was the issue.
I can't seem to find what the problem is.?

Nate


Re: Time from an Analog

 

Thanks Guys!

Phil, yes an SG panel and that was what I was looking/hoping for. Formats just as I wanted...? I'm using the (cm) CountDown Timer module.
When initially triggers, the analog populates as expected (xx:yy:zz), However, as the seconds count down (I see it decrementing in Debug) the display does not change. until I hit the STOP button on the CDTimer. At this point the display updates to the current time.

If I send values in DBg directly,? the display updates.
If I set up an Analog Increment with a 1d increment value, the Display counts as expected!!
I put the CDT Analog thru ABUFs and even though the values change in DBg, the display doesn't until the Timer is stopped.
?Its as if the Display object knows that the Analog decrement is coming from the CDT vs. my manual triggers - this of course doesn't make any sense!!

? ?Any ideas??? TIA!


CH volume not following the bindings

 

I have a samsung frame tv controlled via LAN with its audio out connected to a 6x100.? In the CH setup the TV apps are setup to use the speaker out #5 but the remote still controls TV volume.??


Long copper run and NVX

 

I have a run that will be about 275ft.? Shielded CAT6A connected to a 10G extreme switch.? I have a fiber there as well and will be prepared to use it.? But, just wondering if anyone has any feedback that has been in this situation.


Re: Time from an Analog

 

Sorry a little mistake

The calculation is the following :
Seconds = TotalTime % 60
Minutes = TotalTime / 60 % 60
Hours = TotalTime? / 3600 % 3600

Regards,

Le?mar. 22 juin 2021 ¨¤?06:42, S¨¦bastien LENOIR via <sebastien.lenoir=[email protected]> a ¨¦crit?:
A simple calculation could help you :

Seconds = TotalTime % 60
Minutes = TotalTime? % 60
Hours = TotalTime? / 3600 % 3600

Regards,


Le?lun. 21 juin 2021 ¨¤?21:38, Phil Bridges <gravityhammer@...> a ¨¦crit?:
If this is a SmartGraphics panel?? Just format the analog as "time"

On Mon, Jun 21, 2021 at 9:25 PM ckangis <chris@...> wrote:
Hi All,
I'm sure this is obvious, but my brain is a bit soft lately...:)

I have an application where I have a 'countdown' analog signal representing time in seconds, where it is hours of time (1 hour = 3600d, 4 hours = 14400d).
I need to display the countdown time on touchpanels in a readable form, preferably hours and minutes.?
Anyone have a module or a simple technique to do this?


Re: Time from an Analog

 

A simple calculation could help you :

Seconds = TotalTime % 60
Minutes = TotalTime? % 60
Hours = TotalTime? / 3600 % 3600

Regards,


Le?lun. 21 juin 2021 ¨¤?21:38, Phil Bridges <gravityhammer@...> a ¨¦crit?:
If this is a SmartGraphics panel?? Just format the analog as "time"

On Mon, Jun 21, 2021 at 9:25 PM ckangis <chris@...> wrote:
Hi All,
I'm sure this is obvious, but my brain is a bit soft lately...:)

I have an application where I have a 'countdown' analog signal representing time in seconds, where it is hours of time (1 hour = 3600d, 4 hours = 14400d).
I need to display the countdown time on touchpanels in a readable form, preferably hours and minutes.?
Anyone have a module or a simple technique to do this?


Re: Crestron Go iphone testing #crestronapp

 

¿ªÔÆÌåÓý

I can report that this fixed the problem for me. ?

Prior to doing this it would sit at loading interface. ?

After wyatts fix when I hit run as it then asked me for the authentication username and password. ?Then the simulator came up on screen.?

Thank you?

On 21 Jun 2021, at 10:24 pm, Wyatt J <wyatt@...> wrote:

?I hit the green play triangle, "Run Project As" at the top all the time with mobile projects and it works fine.? If you get a simulator that is blank you have to change the Advanced Attributes in windows to fix the issue.

  1. Right click on the folder containing your VT project
  2. Choose properties
  3. Click advanced
  4. Check "Allow files in this folder to have contents indexed in addition to file properties"
  5. Click ok
  6. Next it will ask you something about propagating to folders inside this one.? Choose yes.

After that the Run As should work.? I've done this a million times and it fixes the issue every time.


Re: Time from an Analog

 

If this is a SmartGraphics panel?? Just format the analog as "time"


On Mon, Jun 21, 2021 at 9:25 PM ckangis <chris@...> wrote:
Hi All,
I'm sure this is obvious, but my brain is a bit soft lately...:)

I have an application where I have a 'countdown' analog signal representing time in seconds, where it is hours of time (1 hour = 3600d, 4 hours = 14400d).
I need to display the countdown time on touchpanels in a readable form, preferably hours and minutes.?
Anyone have a module or a simple technique to do this?


Time from an Analog

 

Hi All,
I'm sure this is obvious, but my brain is a bit soft lately...:)

I have an application where I have a 'countdown' analog signal representing time in seconds, where it is hours of time (1 hour = 3600d, 4 hours = 14400d).
I need to display the countdown time on touchpanels in a readable form, preferably hours and minutes.?
Anyone have a module or a simple technique to do this?


Re: File /Documents/Integration with LiftMaster MyQ Garage Door Opener.pdf uploaded #file-notice

 

I have not had the occasion to test this. I may have something coming up in the next 1-2 months but it is simple enough that I'm fairly confident in it...


Re: File /Documents/Integration with LiftMaster MyQ Garage Door Opener.pdf uploaded #file-notice

 

hello, where you able to test this? did it work?
TIA


Re: RMC and CP2 Remote Cresnet Processing to two processors

 

¿ªÔÆÌåÓý

Exactly Lincoln ¨C thanks for clarifying.

?

Cheers, Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von Lincoln King-Cliby via groups.io
Gesendet: Montag, 21. Juni 2021 15:53
An: [email protected]
Betreff: Re: [crestron] RMC and CP2 Remote Cresnet Processing to two processors

?

I believe what Thorsten is saying is that in the existing program they¡¯re currently being used as Ethernet IO devices (along the lines of a QM-RMC in ESlave mode without the processing power) ¨C I may or may not have done this at home from time to time for some quick and dirty IO¡­

?

Since DM-RMC-100s only support a single Ethernet master IP table entry, because they¡¯re being used that way in the existing program he can¡¯t also have them directly talking to the ¡°new¡± program/processor at the same time ¨C so if he wants to be able to keep the old program running while testing new programming (or moving chunks of logic at a time) an EISC is needed to pipeline control between the two masters.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of Steve Kuehn
Sent: Monday, June 21, 2021 9:41 AM
To: [email protected]
Subject: Re: [crestron] RMC and CP2 Remote Cresnet Processing to two processors

?

If you aren't even using the HDMI, just leave the DM port disconnected and connect them to the LAN via the LAN port instead.? No need to EISCs to them.? They will just be another Ethernet device hanging off the LAN.? The only purpose? of the DM-TX-4KZ-100-C-1G is to get HDMI to them.

Thorsten K?hler

2:13am ?

Hi,

?

thanks for the suggestion, but that would be bit over the top.

There are a couple of RMC-100 and they are not even used for HDMI, but only for IR/RS232.

So I think i?ll go with EISCs.

?

Cheers, Thorsten


Re: Crestron Go iphone testing #crestronapp

 

I just tried Wyatt's fix but it did not work for me.? When I went to change the setting, it was already checked.? So I unchecked it, tried it, didn't work.? Then went back and re-checked the box, tried it again, still no dice.?

Thanks for posting though, I used it all the time before, now like the op it works with everything but the app.?


Re: RMC and CP2 Remote Cresnet Processing to two processors

 

¿ªÔÆÌåÓý

I believe what Thorsten is saying is that in the existing program they¡¯re currently being used as Ethernet IO devices (along the lines of a QM-RMC in ESlave mode without the processing power) ¨C I may or may not have done this at home from time to time for some quick and dirty IO¡­

?

Since DM-RMC-100s only support a single Ethernet master IP table entry, because they¡¯re being used that way in the existing program he can¡¯t also have them directly talking to the ¡°new¡± program/processor at the same time ¨C so if he wants to be able to keep the old program running while testing new programming (or moving chunks of logic at a time) an EISC is needed to pipeline control between the two masters.

?

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of Steve Kuehn
Sent: Monday, June 21, 2021 9:41 AM
To: [email protected]
Subject: Re: [crestron] RMC and CP2 Remote Cresnet Processing to two processors

?

If you aren't even using the HDMI, just leave the DM port disconnected and connect them to the LAN via the LAN port instead.? No need to EISCs to them.? They will just be another Ethernet device hanging off the LAN.? The only purpose? of the DM-TX-4KZ-100-C-1G is to get HDMI to them.

Thorsten K?hler

2:13am ?

Hi,

?

thanks for the suggestion, but that would be bit over the top.

There are a couple of RMC-100 and they are not even used for HDMI, but only for IR/RS232.

So I think i?ll go with EISCs.

?

Cheers, Thorsten


Re: RMC and CP2 Remote Cresnet Processing to two processors

 

If you aren't even using the HDMI, just leave the DM port disconnected and connect them to the LAN via the LAN port instead.? No need to EISCs to them.? They will just be another Ethernet device hanging off the LAN.? The only purpose? of the DM-TX-4KZ-100-C-1G is to get HDMI to them.


Thorsten K?hler
2:13am ?

Hi,

?

thanks for the suggestion, but that would be bit over the top.

There are a couple of RMC-100 and they are not even used for HDMI, but only for IR/RS232.

So I think i?ll go with EISCs.

?

Cheers, Thorsten


Re: Error: CPHProcessor.exe # 2021-06-13 23:55:47 # Failed to allocate memory for response in respond api

 

So since updating to the 1.8 FW I'm now getting these errors & restarts once a day as opposed to once every four days before.
I'm going to roll back to a much earlier FW when I get home at the end of the week.
This is with all the cloud BS turned off.

I don't have anything using ping.

Regards
-s


Re: Crestron Go iphone testing #crestronapp

 

I hit the green play triangle, "Run Project As" at the top all the time with mobile projects and it works fine.? If you get a simulator that is blank you have to change the Advanced Attributes in windows to fix the issue.

  1. Right click on the folder containing your VT project
  2. Choose properties
  3. Click advanced
  4. Check "Allow files in this folder to have contents indexed in addition to file properties"
  5. Click ok
  6. Next it will ask you something about propagating to folders inside this one.? Choose yes.

After that the Run As should work.? I've done this a million times and it fixes the issue every time.