I believe one retrofit project I did the network design/configuration/commissioning for we had one run (Cat5-pre-E) with a cable run in the ¡°it might have actually been slightly longer than 300 ft/100 meter¡± range and the NVX device at the end of the cable (pretty sure it was a D30) has had no issues. I think that might have even been with PoE but I¡¯m a little foggy on the physical details since that was largely beyond my responsibility.

?

Over that distance I¡¯d be more concerned about PoE if you were going to try to use it, particularly PoE++/UPOE-type power consumption than data integrity, but since you mentioned having fiber I can assume you¡¯re planning on locally powering anyway.

?

Of course using a proper cable certifier to make sure the cable and terminations are completely happy with the world is always a good idea.

?

Lincoln

--

Lincoln King-Cliby, CTS, DMC-E-4K/T/D
Commercial Market Director
Sr. Systems Architect | Crestron Certified Master Programmer (Diamond)
ControlWorks Consulting, LLC
Direct: (+1)440.771.4807 | Cleveland: (+1)440.449.1100? | Boston: (+1)508.695.0188 | DC: (+1)202.381.9070? | Fax: (+1)440.449.1106
Crestron Services Provider | Biamp Authorized Independent Programmers | Extron Qualified Independent Programmer

?

From: [email protected] [mailto:[email protected]] On Behalf Of John Gabler
Sent: Tuesday, June 22, 2021 11:26 AM
To: [email protected]
Subject: [crestron] Long copper run and NVX

?

I have a run that will be about 275ft.? Shielded CAT6A connected to a 10G extreme switch.? I have a fiber there as well and will be prepared to use it.? But, just wondering if anyone has any feedback that has been in this situation.

Join [email protected] to automatically receive all group messages.