Re: Crestron APP block notification #app

 

Guided access is the way to go, you just need to factor in onsite support when it goes wrong. ? If the ipad needs to be restarted or the App force closed / restarted and you don't want anyone having the passcode you will physically need to go to the device.

we use the app on ipads in a number of communal settings without guided access mode. ? ?We just restrict the app settings page and set it to auto load and therefore its very difficult for anyone to get in to the app to change things. ? We then remove all the other ipad apps for the device leaving only the Creston App on the first page and sign out of app store etc.

its still possible for someone to screw up the ipad but its a compromise between useability and allowing local onsite support.


Re: Sirrus/XM Comtrol and Feedback

 

The short answer is no - there is no current product that does what you're looking for.? Everything outside the car moved to streaming 5+ years ago.? You may find some old units that support RS232 control but there is nothing current that's satellite-based.
?- Dave


Re: Published Voltage Fluctuations

 

Most Crestron equipment? (except for power amplifiers) today have switching power supplies where the neutral/line are completely isolated ? from ground and can tolerant quite a bit of voltage on the ground with respect to neutral (as long as they aren't connected to anything else).? It depends on the power supply and the load but I see a lot of stuff that will operated all the way down to 60VAC line.? A bigger issue is brown outs and power glitches.? Some stuff can tolerate a brown out of any level and not lock up.? More the normal is some equipment will lock up with a power glitch and require a hard boot to restore operation.? But on the worst end, some stuff that I work on will literally blow up with a very expensive repair if the line voltage drops below 110V. I don't think you will find a spec more detailed than the range of voltage operation.? For example, my laptop power supply is spec to operate on anything between 100 to 240VAC.

If you lift the ground on a piece of equipment, many, if not most, will have about half the mains line voltage (60VAC in the USA) on the ground pin and they will continue to operate properly.? The issues however can occur when you start connection stuff together.? It is the ground different between different pieces of equipment that will cause the damage.

For example, we had a Samsung TV that just had a 2 pin power plug.? If you measured the case of the TV to the ground pin in the wall outlet, it was 60VAC.? The current however on the ground was quite low so it wouldn't even shock you.? And the TV worked fine too.? Connect anything to it that was grounded and the voltage drop to zero. But when you connect the HDMI cable from a Control4 room box to it, the 60VAC ground voltage blew up the Control4 receiver.??? We landed up connecting a ground wire between the TV chassis and the wall outlet ground and had no more issues with Control4 blowing up.

At another employer I work for, 90% of the HDMI boards we replace? in receivers have blown up CBL/SAT HDMI inputs.? The reason is many Cable and Satellite systems are grounded outside the house at a different grounding? point that the power line (usually near the power pole) -- that is what code requires too.? Ideally, you want your cable satellite provider to also ground the cable to the electrical? panel when it comes in the house.? If it is not, that is when the CBL/SAT inputs get zapped.


Re: Published Voltage Fluctuations

 

¿ªÔÆÌåÓý

The question is in regard to the voltage differential that can be measured between ground and neutral. ?It can be induced by certain types of loads.?
We have a power monitor from surgeX that we are using to diagnose bad power on specific job sites. On certain sites the N to G voltage is as low as 0.1 V. At other sites it is as high as 1.3 V.

Ryan Cunningham?

On Jan 9, 2021, at 4:06 PM, RobertF <r_finley@...> wrote:

?

[Edited Message Follows]

Neutral to mains ground?? ?

Earth ground should not be shorted to neutral anywhere outside the breaker box.? So, I don't know if the ground/neutral voltage difference is problematic.? On nearly all power supplies with a neutral and earth-ground 3-pin plug, there is a common-mode choke transformer in-line with hot and neutral.? Earth ground connects two capacitors, each to hot and neutral to filter.? ? Those EMI filter capacitors can cause 2V/AC that you measure at the wall.??

IMHO, things lock up from transient dropouts on DC power.? ?Is the power supply for the processor loaded near max ratings??

One advantage to 24V is you have a lot of headroom before you reach the minimum voltage needed to generate 5V/3.3V etc.

What else is sharing the supply powering the processor?


Re: Published Voltage Fluctuations

 
Edited

Neutral to mains ground?? ?

Earth ground should not be shorted to neutral anywhere outside the breaker box.? So, I don't know if the ground/neutral voltage difference is problematic.? On nearly all power supplies with a neutral and earth-ground 3-pin plug, there is a common-mode choke transformer in-line with hot and neutral.? Earth ground connects two capacitors, each to hot and neutral to filter.? ? Those EMI filter capacitors can cause 2V/AC that you measure at the wall.??

IMHO, things lock up from transient dropouts on DC power.? ?Is the power supply for the processor loaded near max ratings??

One advantage to 24V is you have a lot of headroom before you reach the minimum voltage needed to generate 5V/3.3V etc.

What else is sharing the supply powering the processor?


Re: Sirrus/XM Comtrol and Feedback

 

Sirius SCH2P Home/Pro tuner.


About 12 years ago, I had problems with the Crestron host seizing up periodically that was fixed by hosting it with its own 2-series (the one that is smaller than a paperback and doesn't have Cresnet).

TBH:? in this day and age?? ?Bluetooth receiver to my phone.? Done.


Re: Crestron APP block notification #app

 

The best way to do this would probably be to turn on ¡°Guided Access¡± mode. ?Essentially, this turns the iPad into a Crestron app only (or whatever app you lock it into). ?You can enable it in the accessibility settings near the bottom of the settings.
I¡¯m not sure how this affects notifications though.
It just locks the iPad on that app and requires a password to unlock it.


Re: wake on lan #crestron

 

An IP Helper address allows you to send broadcast traffic across vlans.? Speak to your network Admin.? They should know how to implement it.? Unfortunately I don't know a great deal about it.? It was actually my clients network Admin that implemented it for me on a job a while back.??

We had 3 crestron processors on one vlan, that had to control over 400 tvs spanning about 8 different vlans.? ?Every TV used WOL to turn on and it all works perfectly.??


Sirrus/XM Comtrol and Feedback

 

Good afternoon,
Crestron doesn't make satellite radio sources anymore.? Is there a current product out there I can use that gives me control and feedback


REGULATORY MODEL: CEN-RFGW-EX2 vs CEN-RFGW-EX the latter works far better with MLX-2

 

So I ran into an issue with some fleebay upgrades I was attempting to do on my home system.

I have a ML-600 and it is awesome but I liked the idea of feedback and a more modern look so I bought a MLX-2 and a gateway.?I stay pretty old as far as hardware goes as I am just using this in my home and it is more of a hobby for me.

I ran into this issue and saw no posts anywhere in regards to this while attempting to troubleshoot. Everything I found here and on reddit said MLX-2 remotes suck and the range is garbage. MLX-3 is the only way to go.

So I first installed the?CEN-RFGW-EX (IC:5683C-CENRFGWEX2) and downgraded the firmware and loaded my program. Worked fine at my desk but the range was like 5 feet and the remote would randomly go RF out of range.

Looked at the Channel configuration and tried 15 and 20. Didn't matter. Turned off all wifi in the house I live out in the country so no neighbors to worry about. Still no change. Bought another MLX-2 and tried that. Same result. Behaves the same way.?Added an Alfa 9db antenna and got some benefits. Was able to actually install it in the Master and use it with some "lag" but good enough for me while I wait for the MLX-3 to show up.

I also bought another CEN-RFGW-EX gateway because I would need one to stay dedicated to the MLX-2 remote and I would just us it in the office or out in the shop for Audio and playing around with.

I received the second CEN-RFGW-EX and was adding it to the system in anticipation of my MLX-3 but for the time being I figured I would use the second MLX-2 remote on it in the office. Low and behold the Range is roughly 40-60 feet with the factory antenna and it works beautifully no lag on feedback. Rock Solid.

I compared the part numbers on the 2 gateways and they are the same but the IC number is different. I'm thinking I just lucked out with the second unit and the old IC (5683C-CENRFGWEX) without the 2 at the end works well with the MLX-2 and the older firmware and I'm betting my MLX-3 and the new firmware is going to work great on the one that ends in 2.

I just wanted to check with the pro's and see if I'm correct on this or is the first gateway I got just defective.

Thanks,
John.


Re: Occupancy/motion sensor

 

Have a look at this
Small, self contained, and we have sucessfully used them for many projects.


Published Voltage Fluctuations

 

4?Does Crestron have stated voltage findings on when processors or devices may experience lock ups when it comes to voltage fluctuations and/or voltages Neutral to Ground?

?

For instance Lutron processors will lock up at 108V or below, Samsung TV¡¯s experience issues at 2V+ neutral to ground. ??have stated voltage findings on when your processors may experience lock ups when it comes to voltage fluctuations and/or voltages Neutral to Ground?

?

For instance Lutron processors will lock up at 108V or below, Samsung TV¡¯s experience issues at 2V+ neutral to ground. ?


Crestron APP block notification #app

 


Is it possible in iOS / Android applications to prohibit / block the display of notifications with access to the settings so that the tablet user cannot access the connection settings. In other words, how to restrict access to the Crestron APP connection settings in a public tablet?


Re: LiftMaster MyQ Garage Door openers

 

Ah I see what you're saying Tony.
I actually (and a friend also) found and extensively tested this issue ~4 years ago and beat on Crestron about it (mercilessly as usual!). My recollection is that they did fix this with the latest firmware.
Also, I think part of the issue is resolved when you use the LINKSTATE extender on the Gateway module. If you're not using this, the unit definitely will not let the system know when it comes back online, at least until a new transition...

Let me know it that works for you...


Re: wake on lan #crestron

 

thank you for your reply.
the processor and pc connected to the same managed switch , but in different subnets.
i believe the solution must come from the network configuration, but i don't know how.
what is the ip helper address ?
i have a working module for wol in the same subnet.

thank you,

assaf?


Re: Occupancy/motion sensor

Phil Millross
 

¿ªÔÆÌåÓý

Hey All,?

This side of the pond a company call faradite make a great little unit?


Again working with constant 24v psu and digital IO ???


On 9 Jan 2021, at 10:37, harryblackman@... wrote:

?I recently used this low voltage PIR sensor to send a trigger to my RMC3 to turn my living room lights on according to the time of day.?
Works well for me



Needs a constant 12-24v feed and connects in to the digital in of your processor.


Re: Occupancy/motion sensor

 

I recently used this low voltage PIR sensor to send a trigger to my RMC3 to turn my living room lights on according to the time of day.?
Works well for me



Needs a constant 12-24v feed and connects in to the digital in of your processor.


Re: Authentication Blocked IP

 

¿ªÔÆÌåÓý

Yes, nobody (except explicitly authorized) should be able to get on the blocking list of an internal Crestron processor¡­

?

?

Von: [email protected] <[email protected]> Im Auftrag von Steve Kuehn
Gesendet: Samstag, 9. Januar 2021 01:38
An: [email protected]
Betreff: Re: [crestron] Authentication Blocked IP

?

We stop exposing ports to the Internet a long time ago because oversea sources were constantly pounding them.? We now use OpenVPN if we need remote access.? If you absolutely must do port forwarding, I advise you to use a router where you can set up firewall rules and then only allow certain IP addresses (e.g. your IP addresses) to pass.


Re: LiftMaster MyQ Garage Door openers

 

The issue occurs with Simpl programs too, not just Crestron Home. However, it's usually easier to come up with a work-around with Simpl.

The problem is caused by the INET-IOEX-RYIO not reporting its input states on program start, so a closed or shorted input will show as open after a program reboot. Correcting the feedback will require either opening then closing the input again, or power-cycling the IOEX.

I normally run the IOEX's power through one of the relays, if they aren't both being used, then program that relay to always be on. That will cause a temporary interruption of power whenever the program restarts, and refresh the inputs' status. If both relays are being used, some other method could be used to reboot the IOEX, or I suppose rebooting the RF gateway would also work - although I haven't tried that.

--- On Friday, January 8, 2021 at 11:29 AM, Evan Kontos wrote:

Ive been using that IOEX for garage doors and it depends upon whether youre
doing it with PYNG or with Simpl. When you first start the system PYNG is
confused with the signal it receives as to whether the door is open or
closed. You have to cycle it once to make sure. THAT is a problem if you are
remote and trying to open your door remotely. A camera in the garage would be
good in addition to the magnetic contact for safety purposes.


Re: wake on lan #crestron

 

Lots more information required.? ?Did you physically just connect the networks?? Are the pc and processor still on different subnets??

I've done WOL before across vlans but had to get the network Admin to setup an IP Helper address.? ?

The magic packet string to send is easy to find.? There are modules on here that work fine.? Your network is the bigger issue.??