Date

Re: AV2 rebooting continously after program upload

 

I had an issue where a comment with "" in the parameter field caused
reboots.

I didn't want it to put anything into console. I was only using as a
placeholder in the logic tree, and as a reminder as I built up the project
and added rooms, and devices, I needed to initialize their crosspoint IDs.
Otherwise it was upload, test, $(*@#&(*&, add the ID, upload.

Taking out the null comment fixed it.

On Tue, May 14, 2013 at 10:19 AM, eagrubbs <eagrubbs@...> wrote:

**


Well that can't be your problem. What other simpl+ stuff do yo have going
on?


--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@...>
wrote:

i have biamp modules in the program only 3 dialer, mic mute and vol
control v5.2

--- In Crestron@..., "eagrubbs" <eagrubbs@> wrote:


What is your dsp in this system? On the av2 I had issues with, the
program was using BSS audio modules. The newest modules off of the BSS site
would lock that av2 everytime. Reverted to some older modules and no more
problems. I could load that same program that would lock the av2 and it
would run fine on MPC-M10. I still would like to know why the av2 would
lock though. The program was really small too: 80 symbols, 314 digital, 24
analog, 25 serial, so I know it wasn't out of memory.


Re: TPMC-12 Cresnet problem

roray32
 

I should of also mentioned that I've tried another panel on the the cabling and it works fine.

--- In Crestron@..., "castor_97" <ecastor@...> wrote:

have you checked the wireing? sounds like there might be a loose connection somewhere.

--- In Crestron@..., "roray32" <roray.stewart@> wrote:

Hi,

I have TPMC-12 which appears to have developed a problem with its Cresnet connection. In toolbox I can see the panel on IP, looking at the AV2 it's connected to it lists no Cresnet devices attached. I have re-uploading the code and have also re-uploaded the firmware to the panel but this has made no difference. I can see the code on the panel but when operating it just carries out page flips, doesn't control the system in any way.

Panel is running firmware: 1.00.02.90

Any ideas as to what else I can check or try before I send it back for repair.

Thanks
Roray


SONY 4K XBR 84X900 series

 

Hi guys,

Just landed a nice programming job... the only problem ...

i have to integrate a sony 4K Tv, and i can't find any doc of the protocol... since the tv has some proprietary functions, i was looking for some kind of a sony document with what is what... and what's it doing...

I'll get the tv on the jobsite and i wanted to prepare my modules before hand...

If anyone is a sony dealer and have some info on this subject, it'll be greatly appreciated...


Thank you,

Stephane,


Re: AV2 rebooting continously after program upload

 

Well that can't be your problem. What other simpl+ stuff do yo have going on?

--- In Crestron@..., "coolaiddrinker" <coolaiddrinker@...> wrote:

i have biamp modules in the program only 3 dialer, mic mute and vol control v5.2

--- In Crestron@..., "eagrubbs" <eagrubbs@> wrote:


What is your dsp in this system? On the av2 I had issues with, the program was using BSS audio modules. The newest modules off of the BSS site would lock that av2 everytime. Reverted to some older modules and no more problems. I could load that same program that would lock the av2 and it would run fine on MPC-M10. I still would like to know why the av2 would lock though. The program was really small too: 80 symbols, 314 digital, 24 analog, 25 serial, so I know it wasn't out of memory.


Re: Certification Test - Messaging from Touchpanel

 

I just took the advanced class the first of March and I also due to my work load haven't been able to spend enough time that I would be able to finish by my deadline. So I emailed Crestron to get an extension and found out that they have dropped the 3 month deadline. I'm not sure how far back that will count for but I was relieved to hear I had more time to finish mine.

Nate L.
On May 14, 2013, at 10:50 AM, "cyberbri24" <cyberbri24@...> wrote:

I guess it's my time to chime in lol...

Been programming for 12 years. Starting out in resi and stayed there for most of that time. Largest system was 22 TP, 20 zones of A/V, 250K theater within, full smart home (HVAC, SHADES, JANDY, CCTV, you name it they had it), and 6 full racks of gear totaling about $1 mil. This was all done only having Essentials experience. From there and attending Intermediate class, everything was easier because most systems was 1-6 rooms. After the market crash I moved over to Commerical because companies have annual budgets to spend and I got in with a few A/V commerical companies always needing programming. I finally took my Cert class very recently but my current workload (which is a good thing)has kept me from finishing my exam. I will finish it at some point, just not sure if they make me attend another class before that happens? Has anyone gone past the 3 months date?
I have been an admin of a few large RVSE systems. From 150 to 250 rooms, I have yet to really use all the features such as room messaging or scheduling as the client always had other SW for making the rooms available so I never needed to worry about it. The clients mostly look for managing and keep track of scheduling the events to shutdown rooms for better bulb life, knowing the lamp hours for PM care and helping assist a user by using the x-panel feature. The rooms need occupency sensors and IP cameras to help aid in knowing if a room is really in use or not or just left on IMO.

Question I have, is there going to be a qwerty keyboard released yet for Core 3UI anytime soon?

Thanks,
cyberbri

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

RV Express has a Help Message and Help Response Text Field...


--- In Crestron@..., Lincoln King-Cliby <lincoln@> wrote:

Yeah, but I don't think RV Express (RV6) supports the messaging, etc. of RV7 / RV SE... I could be wrong since it's been more than a few years since I've seen anyone do RV SE so maybe that capability has been added [or has been there all along and, as I said, I just have never had a need for it]

Lincoln

[Non-text portions of this message have been removed]


Re: mlx-3

 

I've done projects with gateways operating via Cresnet (8 remotes, 6 remotes), no issues.

Tom L.

--- In Crestron@..., Nick Mitchell <nick@...> wrote:

Kevin,

Don't switch them to cresnet. We saw lots of performance issues with
gateways and cresnet. Invest in a UPS so it doesn't loose power lol.

Nick



Sent from my eMail.

On May 14, 2013, at 9:18 AM, Kevin Keenan <kevinfkeenan@...> wrote:



I have a project with 7 MLX-3 s and three gateways connected to a CP3 via a
Pakedge POE switch. Every time the customer loses power, the gateways lock
up. (They usually blame the remotes, but pulling the batteries or rebooting
the MLX-3 does not help) We have to cycle the power on the gateways and
wait about 10 minutes, then all is fine.

I am thinking about rewiring the gateways to use Cresnet instead of
Ethernet.

-Kevin

On May 13, 2013, at 18:51, "chrish172003" <chris@...> wrote:

just out of interest has anyone experienced any lockups with the mlx-3 on
the mc3?

panel comes unresponsive and then you have to reboot the gway to or pull
the batteries on the panel to get it to work again

[Non-text portions of this message have been removed]




[Non-text portions of this message have been removed]


Re: AV2 rebooting continously after program upload

 

i have biamp modules in the program only 3 dialer, mic mute and vol control v5.2

--- In Crestron@..., "eagrubbs" <eagrubbs@...> wrote:


What is your dsp in this system? On the av2 I had issues with, the program was using BSS audio modules. The newest modules off of the BSS site would lock that av2 everytime. Reverted to some older modules and no more problems. I could load that same program that would lock the av2 and it would run fine on MPC-M10. I still would like to know why the av2 would lock though. The program was really small too: 80 symbols, 314 digital, 24 analog, 25 serial, so I know it wasn't out of memory.


Re: I have a shirt.... Old Crestron Swirl

 

DMPS update, yes you have some time on your hands, but wait until you do a fully loaded 32x32 to the newest firmware. You might as well take the day off.

I do remember that swirl, the solid color looks better.

--- In Crestron@..., Tom Mclaughlin <tmclaughlin@...> wrote:

Hea,

Does anyone remember the old Crestron Swirl?
It's logo was the original 'Rainbow' colors before Crestron changed to solid "anti-rainbow" (all blue or white).
Denim Crestron Certified with the old Swirl, and I was wondering....

Do the Crestron Swirls in Australia or Southern Hemisphere go Counterclockwise?
Just wondering if it was an urban legend.....

Sorry for the BS post,
I have a lot of time on my hands...

updating DMPS300s.

Tom




GreenPoint TDI accepting applications

 

GreenPoint TDI, a leading commercial control systems software company in Phoenix, Arizona is currently accepting applications for apprentice and experienced programmers/configuration Field techs in the Las Vegas and Phoenix markets. Please feel free to email me with requirement questions and any information requests. scotts@...


I have a shirt.... Old Crestron Swirl

 

Hea,

Does anyone remember the old Crestron Swirl?
It's logo was the original 'Rainbow' colors before Crestron changed to solid "anti-rainbow" (all blue or white).
Denim Crestron Certified with the old Swirl, and I was wondering....

Do the Crestron Swirls in Australia or Southern Hemisphere go Counterclockwise?
Just wondering if it was an urban legend.....

Sorry for the BS post,
I have a lot of time on my hands...

updating DMPS300s.

Tom


Re: Certification Test - Messaging from Touchpanel

 

Really? Even the tpmc-4smd? I will have to research this.

Nick

Sent from my eMail.

On May 14, 2013, at 10:54 AM, Neil Dorin <neildorin@...> wrote:



Every Core3UI panel has a qwerty keyboard built in....
On 2013-05-14, at 8:50 AM, "cyberbri24" <cyberbri24@...> wrote:

I guess it's my time to chime in lol...

Been programming for 12 years. Starting out in resi and stayed there for
most of that time. Largest system was 22 TP, 20 zones of A/V, 250K theater
within, full smart home (HVAC, SHADES, JANDY, CCTV, you name it they had
it), and 6 full racks of gear totaling about $1 mil. This was all done only
having Essentials experience. From there and attending Intermediate class,
everything was easier because most systems was 1-6 rooms. After the market
crash I moved over to Commerical because companies have annual budgets to
spend and I got in with a few A/V commerical companies always needing
programming. I finally took my Cert class very recently but my current
workload (which is a good thing)has kept me from finishing my exam. I will
finish it at some point, just not sure if they make me attend another class
before that happens? Has anyone gone past the 3 months date?
I have been an admin of a few large RVSE systems. From 150 to 250 rooms,
I have yet to really use all the features such as room messaging or
scheduling as the client always had other SW for making the rooms available
so I never needed to worry about it. The clients mostly look for managing
and keep track of scheduling the events to shutdown rooms for better bulb
life, knowing the lamp hours for PM care and helping assist a user by using
the x-panel feature. The rooms need occupency sensors and IP cameras to
help aid in knowing if a room is really in use or not or just left on IMO.

Question I have, is there going to be a qwerty keyboard released yet for
Core 3UI anytime soon?

Thanks,
cyberbri

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

RV Express has a Help Message and Help Response Text Field...


--- In Crestron@..., Lincoln King-Cliby <lincoln@> wrote:

Yeah, but I don't think RV Express (RV6) supports the messaging, etc.
of RV7 / RV SE... I could be wrong since it's been more than a few years
since I've seen anyone do RV SE so maybe that capability has been added [or
has been there all along and, as I said, I just have never had a need for
it]

Lincoln
[Non-text portions of this message have been removed]


Re: Certification Test - Messaging from Touchpanel

 

Every Core3UI panel has a qwerty keyboard built in....
On 2013-05-14, at 8:50 AM, "cyberbri24" <cyberbri24@...> wrote:

I guess it's my time to chime in lol...

Been programming for 12 years. Starting out in resi and stayed there for most of that time. Largest system was 22 TP, 20 zones of A/V, 250K theater within, full smart home (HVAC, SHADES, JANDY, CCTV, you name it they had it), and 6 full racks of gear totaling about $1 mil. This was all done only having Essentials experience. From there and attending Intermediate class, everything was easier because most systems was 1-6 rooms. After the market crash I moved over to Commerical because companies have annual budgets to spend and I got in with a few A/V commerical companies always needing programming. I finally took my Cert class very recently but my current workload (which is a good thing)has kept me from finishing my exam. I will finish it at some point, just not sure if they make me attend another class before that happens? Has anyone gone past the 3 months date?
I have been an admin of a few large RVSE systems. From 150 to 250 rooms, I have yet to really use all the features such as room messaging or scheduling as the client always had other SW for making the rooms available so I never needed to worry about it. The clients mostly look for managing and keep track of scheduling the events to shutdown rooms for better bulb life, knowing the lamp hours for PM care and helping assist a user by using the x-panel feature. The rooms need occupency sensors and IP cameras to help aid in knowing if a room is really in use or not or just left on IMO.

Question I have, is there going to be a qwerty keyboard released yet for Core 3UI anytime soon?

Thanks,
cyberbri

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

RV Express has a Help Message and Help Response Text Field...


--- In Crestron@..., Lincoln King-Cliby <lincoln@> wrote:

Yeah, but I don't think RV Express (RV6) supports the messaging, etc. of RV7 / RV SE... I could be wrong since it's been more than a few years since I've seen anyone do RV SE so maybe that capability has been added [or has been there all along and, as I said, I just have never had a need for it]

Lincoln

[Non-text portions of this message have been removed]


Re: Certification Test - Messaging from Touchpanel

cyberbri24
 

I guess it's my time to chime in lol...

Been programming for 12 years. Starting out in resi and stayed there for most of that time. Largest system was 22 TP, 20 zones of A/V, 250K theater within, full smart home (HVAC, SHADES, JANDY, CCTV, you name it they had it), and 6 full racks of gear totaling about $1 mil. This was all done only having Essentials experience. From there and attending Intermediate class, everything was easier because most systems was 1-6 rooms. After the market crash I moved over to Commerical because companies have annual budgets to spend and I got in with a few A/V commerical companies always needing programming. I finally took my Cert class very recently but my current workload (which is a good thing)has kept me from finishing my exam. I will finish it at some point, just not sure if they make me attend another class before that happens? Has anyone gone past the 3 months date?
I have been an admin of a few large RVSE systems. From 150 to 250 rooms, I have yet to really use all the features such as room messaging or scheduling as the client always had other SW for making the rooms available so I never needed to worry about it. The clients mostly look for managing and keep track of scheduling the events to shutdown rooms for better bulb life, knowing the lamp hours for PM care and helping assist a user by using the x-panel feature. The rooms need occupency sensors and IP cameras to help aid in knowing if a room is really in use or not or just left on IMO.

Question I have, is there going to be a qwerty keyboard released yet for Core 3UI anytime soon?

Thanks,
cyberbri

--- In Crestron@..., "jbudz1977" <jbudz1977@...> wrote:

RV Express has a Help Message and Help Response Text Field...


--- In Crestron@..., Lincoln King-Cliby <lincoln@> wrote:

Yeah, but I don't think RV Express (RV6) supports the messaging, etc. of RV7 / RV SE... I could be wrong since it's been more than a few years since I've seen anyone do RV SE so maybe that capability has been added [or has been there all along and, as I said, I just have never had a need for it]

Lincoln


Re: TPMC-10 do not boot, no Setup access

 

I try something but no Results:

I dont use an akku - because he was dead
I dieassembled the TPMC and there is no Drive inside.
I put the oldest an newest firmware as zip, csz and the content extractet from the csz on a Stick and boot with it. (stick flashes shortly but no result)
I boot with holding the "4" button (viewsonic calls it "Dashboard") the the USB Disaster Recovery Mode Apears - Win 7 find a
"ViewSonic airpanel v110 smart display" and Win XP a "airpanel v210c wireless smart display" Win 7 dont need a driver - but the windows mobile device center find nothing - the Win XP has no drivers - and i find non in the web too.

I search tonight for an pcmcia cf adapter and try that tomorrow. I hope anyone of you has an idea to reaktive this touchpanel.


Greetings FT


Re: AV2 rebooting continously after program upload

 

What is your dsp in this system? On the av2 I had issues with, the program was using BSS audio modules. The newest modules off of the BSS site would lock that av2 everytime. Reverted to some older modules and no more problems. I could load that same program that would lock the av2 and it would run fine on MPC-M10. I still would like to know why the av2 would lock though. The program was really small too: 80 symbols, 314 digital, 24 analog, 25 serial, so I know it wasn't out of memory.


Re: TPMC-12 Cresnet problem

castor_97
 

have you checked the wireing? sounds like there might be a loose connection somewhere.

--- In Crestron@..., "roray32" <roray.stewart@...> wrote:

Hi,

I have TPMC-12 which appears to have developed a problem with its Cresnet connection. In toolbox I can see the panel on IP, looking at the AV2 it's connected to it lists no Cresnet devices attached. I have re-uploading the code and have also re-uploaded the firmware to the panel but this has made no difference. I can see the code on the panel but when operating it just carries out page flips, doesn't control the system in any way.

Panel is running firmware: 1.00.02.90

Any ideas as to what else I can check or try before I send it back for repair.

Thanks
Roray


Re: Opinions on Media Player Core3/SmartGraphics object?

 

Thanks, all.

On Mon, May 13, 2013 at 11:22 AM, Tony Golden <mrgolden@...>wrote:

**


I used the Media Player object for the first time last month, with several
TSW
panels, a couple of DGE-2's, and an X-Panel. We used it with an IDOC and
CEN-TRACK (AM, FM, XM, and AUDIONET).

Some of the features were nice, but I REALLY disliked not being able to
change
(easily) simple things like object & font sizes, placement, and even button
labels.

It was also VERY SLOW to startup. I don't know if that was because we were
using multiple sources, or if that's just how it is, but it was noticeable
and
annoying. Overall I wasn't impressed, and will continue to use "the old
way"
for those sources unless someone specifically requests the Media Player,
or it
gets a lot better.


--- On Monday, May 13, 2013 at 8:21 AM, Phil Bridges wrote:

Have any of y'all used this in a production environment?

I'm looking for opinions on its use, particularly with an iDoc and
Audionet.


Re: TPS-6X Screen Change

 

We just had Crestron do it on one of our jobs. Its about $500.

Jon


Re: mlx-3

 

Kevin,

Don't switch them to cresnet. We saw lots of performance issues with
gateways and cresnet. Invest in a UPS so it doesn't loose power lol.

Nick



Sent from my eMail.

On May 14, 2013, at 9:18 AM, Kevin Keenan <kevinfkeenan@...> wrote:



I have a project with 7 MLX-3 s and three gateways connected to a CP3 via a
Pakedge POE switch. Every time the customer loses power, the gateways lock
up. (They usually blame the remotes, but pulling the batteries or rebooting
the MLX-3 does not help) We have to cycle the power on the gateways and
wait about 10 minutes, then all is fine.

I am thinking about rewiring the gateways to use Cresnet instead of
Ethernet.

-Kevin

On May 13, 2013, at 18:51, "chrish172003" <chris@...> wrote:

just out of interest has anyone experienced any lockups with the mlx-3 on
the mc3?

panel comes unresponsive and then you have to reboot the gway to or pull
the batteries on the panel to get it to work again

[Non-text portions of this message have been removed]




[Non-text portions of this message have been removed]


Re: mlx-3

 

Don't know if this could help: we had PoE problems by using an manageable PoE Switch to power up TSW-750. From time to time, we lost connection between AV3 and some TSW-750, even if they was powered up. Then, we couldn't ping the faulty TSW-750. The Switch had enough PoE power, but for some reason it locks up. By power cycling the switch, we sometimes gain control, so we finaly change the manageable PoE Switch for an umanageable PoE one (the Crestron CEN-SW-POE-5) and didn't heard about it :-). We think our problems are related with the 'manageable' and we try to manage without success :-(.

AD

--- In Crestron@..., Kevin Keenan <kevinfkeenan@...> wrote:

I have a project with 7 MLX-3 s and three gateways connected to a CP3 via a Pakedge POE switch. Every time the customer loses power, the gateways lock up. (They usually blame the remotes, but pulling the batteries or rebooting the MLX-3 does not help) We have to cycle the power on the gateways and wait about 10 minutes, then all is fine.

I am thinking about rewiring the gateways to use Cresnet instead of Ethernet.

-Kevin

On May 13, 2013, at 18:51, "chrish172003" <chris@...> wrote:

just out of interest has anyone experienced any lockups with the mlx-3 on the mc3?

panel comes unresponsive and then you have to reboot the gway to or pull the batteries on the panel to get it to work again


[Non-text portions of this message have been removed]