¿ªÔÆÌåÓý

ctrl + shift + ? for shortcuts
© 2025 Groups.io
Date
Re: Serial Connection to 2 Series Processors
How about Viewport?
By Deuterios · #254055 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
In my software TSW is iPID 41, when I changed ip table of TSW to IPID 41 istead of 03 and waited and waited after 2-3 min it come up online, to be honest I tried that before but I guess I am not
By norbert.pajek@... · #254054 ·
Re: Copying D3Pro keypad properties
Exactly... 45 x 120... Tony, its only time...time has no value, right???? (Crestron, who do I send my invoice to??)
By ckangis · #254053 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
That doesn't seem right. First in your SMW program, is the TSW at 03 or 41? i.e. the IP-ID of the TouchPanel device symbol. The IP-ID in your program must match the IP Table entry in your TSW. So if
By ckangis · #254052 ·
Re: Copying D3Pro keypad properties
Yeah, the "Global Updates" function only sets the backlight and indicator brightness - which is only five or six of the possible 45 or so settings :-)
By Tony Golden · #254051 ·
Re: Crestron APP thru VPN on T-Mobile
Still having issues with this. Also a client with Verizon. It will work sometimes but have never seem this before a ew months ago... Anyone else seeing these issues?? And Crestron, When are we going
By ckangis · #254050 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
When I go to system info my touchpannel has loop back ip adress...
By norbert.pajek@... · #254049 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
Ok In my program TSW770 is IPID 41 with ip 192.168.10.11 and my control unit RMC4 ip is 192.168.10.12 (ip table was given to me by project menager). On the ip table on the control unit I have IPID 41
By norbert.pajek@... · #254048 ·
Serial Connection to 2 Series Processors
Has anyone had any issues lately with connecting to the old 2 series processors with toolbox? I was on site trying to connect to one and also tried a couple other i=ones back at the shop and says
By Dan Gawne · #254047 ·
Ip table offline on Touchpanel
Hello, I have RMC4 as my control unit and TSW-770 B S as my touchpanel, I had added ip table with my RMC4 ip number on my touchscreen but it shows offline, on the control unit ip table shows that
By norbert.pajek@... · #254046 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
Did you set the parameters (IPID as in the program and processor IP/hostname) in the TSW770? Cheers, Thorsten Von: [email protected] <[email protected]> Im Auftrag von
By Thorsten K?hler · #254045 ·
Re: Copying D3Pro keypad properties
I haven't checked in the last few years (I ask myself: "Why Would I?") but when I did my first HZ project~ 4 years ago there was no way to do it. 120 HZ dimmers, each hand-crafted by me...:( I did
By ckangis · #254044 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
Hello All, Yes I tried that many times the issue was different.... So apparently Johathan asnwered me for the same question on crestron community, the issue was that in my project name I used TSW-770
By norbert.pajek@... · #254043 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
What Thorsten said. I'm sure that's your issue...
By ckangis · #254042 ·
Re: Touchpanel TSW 770 B-S Does not want to enter user project application
Hi, did you change the TSW application mode to ¡°User Project¡±? You can do that via the Touchpanel GUI => Settings=>Applications=>Application Mode => User Project Cheers, Thorsten Von:
By Thorsten K?hler · #254041 ·
Touchpanel TSW 770 B-S Does not want to enter user project application
Hello, I have here my touchpanell TSW 770 B-S with firmware version 2.004.1079. I am able to sent my GUI project to the panel but everytime it reboots it enters crestron default mode. I cannot force
By norbert.pajek@... · #254040 ·
Copying D3Pro keypad properties
I have a D3Pro program with lots of Horizon keypads.? Once I get the Behavior Properties "just right" on one keypad, it would be nice to simply copy those settings to other keypads.? Does anyone
By Tony Golden · #254039 ·
Re: RMC4 Slave mode
Hi, thank you for your reply I login into webinterface and configure network to specific ip adress, slave mode is off. Right now I am starting from begining to create a program (installation is not
By norbert.pajek@... · #254038 ·
Re: RMC4 Slave mode
I¡¯m coding for one of these right now (awaiting actual unit), so this caught my attention. Have you logged into its web browser and configured it or checked its settings? See this
By Jim · #254037 ·
Re: DM-NAX and QSYS
Hi, I never worked with the NAX-AUD-USB, just a rough guess: Are you sending a single AES channel to the NAX-AUD-USB? If so, try sending two channels. Best regards Crestronfreak55
By crestronfreak55 · #254035 ·