Re: Code from MC3 to CP3N
U need to change the control system in simpl and then recompile the program and send it to the control system.
By @blue_thunder · #253395 ·
Re: Sonos control is still working?
Thanks for the help. System is updated to last sw so S2 system. Things are still not good, the media server cannot communicate with device module/system. I have updated the modules to the last
By Gius Sarg · #253394 ·
Getting Teams meeting end time into simpl?
Hi Has anyone come across a way to get the end time of a meeting into simpl so it can then be used as a trigger? The client is requesting a pop-up page be recalled on the Flex TP as a meeting comes to
By alex@... · #253393 ·
Sensibo x Crestron Home
Hi, anyone with any experience with Sensibo x Crestron Home? I started my journey in Crestron through CH and I have no experience in SIMPL. I've been using Sensibo Sky for some time with the driver
By Remo · #253392 ·
I need your help #simplsharppro #simplwindows #cp4 #crestron #crestronhome
I Have a Clipsal Dali Gateway for lighting control I need any method to integrate with Crestron Any Module except that found at the App Market
By Tamer Mahany · #253391 ·
Re: Code from MC3 to CP3N
If you're just looking to test the code in debugger or test UIs, it will run the code but because the slots are not the same I would not expect connected devices to work. You can right click on the
By Gary Miller · #253390 ·
Re: Code from MC3 to CP3N
You will need to recompile, as the processor is different. <orlandoj.floresf@...> wrote:
By Macross · #253389 ·
Code from MC3 to CP3N
Hello Chic@s , I need your advice. I have a code that was originally used with an MC3 processor, but now I'm using a CP3N. When I try to load the code onto my CP3N, I encounter this error: " *The
By Orlando Flores · #253388 ·
Re: Sonos control is still working?
Last time I dealt with this, I ran the Sonos integration in a different slot and had to reboot it every night. I had to firmware update the controller, update the modules and recompile. I still had to
By Macross · #253387 ·
Re: Sonos control is still working?
Exactly what ckangis said. DO NOT integrate Sonos with Crestron it will be a complete nightmare for you. I am dealing with a system now, where it will work great for a couple of days before it
By Crestron_Programmer · #253386 ·
Re: Sonos control is still working?
Yes things are still working, though neither Crestron or Sonos has dealt with the general communications unreliability over the last 5+ years... First is this an S1 or S2 Sonos setup? Though S1 should
By ckangis · #253385 ·
Sonos control is still working?
Hello to everybody, Could you confirm that the Sonos integration in Crestron is still working? I have a system with Sonos system module + Sonos device module + media object module that stop working. I
By Gius Sarg · #253384 ·
Re: Converting from Pyng (CH) to D3Pro
No, I don't expect it to be THAT easy :-) I was thinking of something to simplify the process of extracting all the device IDs, load/room names, scene definitions, etc. I realize I will then have to
By Tony Golden · #253383 ·
Re: Country Coach Project Files
If you can connect to the processor with text console and type ProgCom, you'll at least see the file path of the current compile and also maybe the programmer/dealer. this may shed some light on who
By ckangis · #253382 ·
Re: Converting from Pyng (CH) to D3Pro
Everything regarding Lighting control is tedious and very site specific...:( Maybe someone else will chime in, but I'm pretty sure that there's no way to go Pyng to D3 in any reliable process...
By ckangis · #253381 ·
Re: NVX Director 160 with multiple classrooms with DMPS-350's
I think adding in the director is making all of this more complicated than it needs to be. Have all your DMPS units talk directly to their in-room NVX units. If you want a "Master" routing
By Chris · #253380 ·
Re: Country Coach Project Files
I know that at some point in time, Country Coach in Eugene did their own programming and possibly still do. It might be worth contacting them directly. [email protected]> wrote:
By BruteForceIsUnderRated · #253379 ·
Converting from Pyng (CH) to D3Pro
I'm switching a fairly large lighting system from an old Pyng Hub to a D3Pro program, and wondered if anyone has done something similar and have any tips to share. My biggest tasks will be documenting
By Tony Golden · #253378 ·
NVX Director 160 with multiple classrooms with DMPS-350's
Hello, I have some simple NVX installations but for the next big roll out we are also installing an NVX Director 160. I have multiple classrooms with DMPS4k-350's for in-room switching (pc,doc cam,
By chuckperkinscrestron · #253377 ·
Re: Country Coach Project Files
The program for your Crestron system was custom made, and I strongly doubt the author is just going to see this and go "hey that's me!". Do some more digging to see if you can find out the name of the
By Jim Germany · #253376 ·