Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
Re: Alternative to NAX-8ZSA?
#crestron
I work for a few dealers that are using amps from AudioControl and Autonomic, which seem to be readily available.
toggle quoted message
Show quoted text
However, I only work with custom-programmed systems, and don't know if there's a Crestron Home driver available for those amps. --- On Monday, April 18, 2022 at 11:02 AM, David Chramcow wrote: |
Alternative to NAX-8ZSA?
#crestron
Hello,
Given that the waiting time for the DM-NAX-8ZSA to ship from Crestron is around ~8 months, what would be a reasonable alternative to that solution from a 3rd party for a Crestron Home install? |
Re: Multiple projects on TSW panel
#tsw
On Mon, Apr 18, 2022 at 07:57 AM, @johnmax wrote:
Ive used it with multiple processors in a redundancy scenario.?That's a good one. Thanks. |
Re: Multiple projects on TSW panel
#tsw
On Sat, Apr 16, 2022 at 11:05 AM, <zac.sparrow@...> wrote:
I have a slight off topic but somewhat related question for you all:Ive used it with multiple processors in a redundancy scenario.? |
Re: Timer module
#programming
Correct, If that limitation would be an issue then that's where you'd have to separate them out into numerous analogs which is still quite trivial.
-- ?
Crestron Service Provider - TBD Enterprises Inc.
|
Re: Strange problem adding DM NVX devices with 7.0.x firmware to Crestrron Home 3.12
¿ªÔÆÌåÓýThat sounds a good amount of time. Presumably you have the right admin credentials. It¡¯s possible for the NVX to block the processors IP which won¡¯t help at all :/Tim Greenbank Control Systems Engineer On 18 Apr 2022, at 13:59, bryan_d_garcia <bdgarcia@...> wrote:
|
Re: Strange problem adding DM NVX devices with 7.0.x firmware to Crestrron Home 3.12
¿ªÔÆÌåÓýHow long are you leaving it after adding?The NVX unit will reboot after adding and this can take a few minutes to fully come back online Tim Greenbank Control Systems Engineer On 18 Apr 2022, at 13:55, bryan_d_garcia <bdgarcia@...> wrote:
|
Strange problem adding DM NVX devices with 7.0.x firmware to Crestrron Home 3.12
I recently upgraded the DM NVX devices to V7.0.x (Latest firmware).? ?I went to add another DM NVX 351C configured as an Encoder.? ?I am using Crestron Home 3.12 at this location.? ?The NVX successfully adds and immediately reports as offline.? I do a repair, says the repair was successful and then again immediately reports as off line.? ?I took a spare NVX 350C and it did the same thing.? ?It seems there may be a bug with adding DM NVX devices with 7.0.x firmware.? ?Has anyone else seen this issue?
Thank you Bryan |
Re: Duplicating zone question
I have no problems power wise with my aes... ?and 3 rooms and in-wall resistor based volume controls, so you should be fine! On Sun, Apr 17, 2022 at 9:08 PM Seadrunk69 <terence.cmb@...> wrote: Go for it! :) |
Re: Duplicating zone question
I just checked, it will handle 4ohm loads On Sun, Apr 17, 2022 at 8:44 PM Seadrunk69 <terence.cmb@...> wrote: You can ganged (wire parallel) the speakers depending on the ohm rating of the speakers.? ?If you have 8 ohm speakers and if the AAE can handle a 4 ohm load it will work. |
Re: Duplicating zone question
Sorry but does ganging the pairs mean putting both pairs of speaker wires in the same terminal in the AAE?? So essentially having two wires (from different speakers) in the plus and two wires in the minus?? Thanks! On Sun, Apr 17, 2022 at 4:58 PM bi0drain <naplesisnotmyhome@...> wrote:
|
Re: Duplicating zone question
Splitter to me in this case is so over-thinking, can gang the pairs together and be fine...... If you NEEDED to could mode the code in such a way that the vars from 1 zone feed the the other... aka the grouping functions On Sun, Apr 17, 2022 at 5:26 PM ktrdsl23 <ktrdsl23@...> wrote:
|
Duplicating zone question
I'm hoping somebody can help me out with what the best thing to do here is.? I self support my old legacy Crestron system.? We are redoing my backyard and adding a big patio.? I currently have two yard speakers attached to my house which goes into a zone on my AAE.? I'd like to add some satellite speakers out on the new patio and the electrician said he will run speaker wire from my basement (where my AAE is located) along with the electrical that he needs to run. I do have one open zone in my AAE but I want all four speakers (two on house and probably two on patio) to always go on and off together.? Am I better off using a speaker splitter and having both sets of speaker wire go into zone 5 on the AAE (through the splitter) or should I have one set of speakers go to zone 5 and one to zone 6 and just have the same signals drive both zone 5 and 6?? If I go with the splitter I don't have to change anything with the code which is always a plus however I didn't know if I may introduce a bunch of other issues using a speaker splitter. Thanks for the help. |
Re: Timer module
#programming
¿ªÔÆÌåÓýAm I missing a more recent message in the thread? The last one before this one I see was from last year¡So I may be missing context but¡ ? A time formatted analog take care of all of this for you ¨C you just provide the number of seconds (or minutes if you want it that way instead) and it¡¯s rendered for you ¨C 1d = 1 second so times up to a bit over 18 hours can be shown with 1 second resolution ? -- Lincoln King-Cliby, CTS, DMC-E-4K/T/D ? From: [email protected] [mailto:[email protected]]
On Behalf Of D_a_n_e
Sent: Friday, April 15, 2022 7:19 PM To: [email protected] Subject: Re: [crestron] Timer module #programming ? what about when you want to have HH:MM:SS? you need to zero the seconds once you hit 60 sec, and start incrementing the minutes, etc. |
Re: Multiple projects on TSW panel
#tsw
In regards to multiple processors : If you use this Make sure you have the page logic at the panel. ?That way if one of the two systems is offline the other one still works. ? |
Re: Connect a MC3 to a CP4-R via Pyng Listen moduel
This has been disabled by default on latest Crestron Home firmware, from the release notes:
By default, on upgrading, the port used by pyng Smart Objects, CEN-TRACK, TSW-x52, and Triggers and Listen modules are disabled. If you want to turn that port back on, you can change this setting under ¡°System Detail & Password Configuration¡±.? |