Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
Connect a MC3 to a CP4-R via Pyng Listen moduel
Ok, got a quick question (I hope).? I have a client where we are converting their system to a Crestron Home system.? To deal with the limitations of the Crestron Home box, we are using an old MC3 to trigger some devices (PROAMP to be specific).? Currently I have the program on the MC3 set up with the "Pyng Connection Configuration" module pointing at the IP address of the CP4-R plus a single "Pyng (Listen for Pyng Events)" module with two signals defined.? The problem is that when I pull up Pair Devices>Device Types>Crestron Wired and Wi-Fi>Ethernet and Wi-Fi, the Listen for Crestron Home Events does not come up.? Even after hitting the rescan button multiple times.? Both processors are on the same IP scheme and both can be pinged from the other one so I know they can talk.? Does anyone have any suggestions?
|
Re: Multiple projects on TSW panel
#tsw
In case you are talking to multiple processors... I've never used it that way.
toggle quoted message
Show quoted text
On Saturday, April 16, 2022, <zac.sparrow@...> wrote: I have a slight off topic but somewhat related question for you all: |
Re: Timer module
#programming
I'm not sure what you're asking specifically, although it would be rather straightforward to use some comparison logic as an extension to the above to achieve this.
-- ?
Crestron Service Provider - TBD Enterprises Inc.
|
Crestron Home debug window
#xpanel
Hi folks,
?
I wonder how I did open debug window in Crestron Home configuration Xpanel.
Are there any hidden shortcuts to operate with?
I have opened it last time but cannot with the way how to do it again. Best regards Kamil |
Re: Multiple projects on TSW panel
#tsw
I have a slight off topic but somewhat related question for you all:
Why does a wired TP has option for multiple IPID masters? In what cases would you use that? |
Infinite Oscillator
I have noticed that the Ethernet Offline Manager is Super laggy, meaning it may take up to a minute for it to report that the EISC is actually Offline. What I've done is added an Oscillator in the first processor that sends a "heartbeat" pulse every two seconds and if the connection between the two processors is somehow broken I know about it almost instantly as the pulses stop coming in. My question is, have any of you ever seen an oscillator stop working? I need this to work reliably for many years.
Thank you, |
Re: Multiple projects on TSW panel
#tsw
BruteForceIsUnderRated, I found your previous post with fput command description. It worked for me. Thank you!
|
Re: Timer module
#programming
what about when you want to have HH:MM:SS? you need to zero the seconds once you hit 60 sec, and start incrementing the minutes, etc.
|
Re: Multiple projects on TSW panel
#tsw
Never heard about fput. So I can save .vtz into /NVRAM at the processor and then load it onto the touchpanel? Do you happen to have an example of how to use this command? |
Re: Multiple projects on TSW panel
#tsw
On Fri, Apr 15, 2022 at 02:31 PM, dmostyka wrote:
If I put different .vtz files in /display/? can I specify which one to load?No, and the vtz is deleted after its loaded. |
Re: Multiple projects on TSW panel
#tsw
Going along with the console projectload at the TSW panel, you might also use the fput command at the processor to push the file to the TSW panel and tell it to load On Fri, Apr 15, 2022 at 11:31 AM dmostyka <dima.flex@...> wrote:
|
Re: HTML5 and Media Player Object
The VTP MPO uses the CRPC protocol which isn't documented. You technically could create an HTML5 MPO like component, but you would need to reverse engineer the CRPC Protocol. I tried a few years ago to get any type of documentation on it from Crestron and was very annoyed after a few months and gave up.
|
Re: Multiple projects on TSW panel
#tsw
I have to use TSW panels. If it was iPad it would be much easier((( And I agree that the whole idea is very strange... But still.? As I said I don't think it's good idea to have all these GUIs in one VTPro project. Quite often when I have even two VTPro projects open it unexpectedly closes. I assume because custom themes are heavy. |
Re: HTML5 and Media Player Object
Hi Nathan,
So does the HTML5 MPO need to be made specific to each device to be controlled vs one MPO that interfaces to whatever device it connects to, that has the proper parameters?? I.e. Can an MPO be built to handle anything that Crestron approves for use with the VTP MPO? TIA! |
Re: Multiple projects on TSW panel
#tsw
If client is set on using the TSW but have 3 different versions. I'm guessing for different users. You could create an Interface setup page that allowed end-user to select theme and interface configuration. In VTP, I would create a page for each Interface version and have subpages to match. Keep labeling consistent so not to be confusing. Have a Main page (1) for the configuration and based on selection will page flip to appropriate page with associated subpages. It will be confusing unless you stay organized in the VTP and Code. Good luck.
|
Re: Multiple projects on TSW panel
#tsw
I think this is a bad idea... but if you really want to you can load projects from console by putting the .vtz file in /display/ then run `projectload`
|