Re: Cisco room devices 4.0 - module cannot find the related CLZ on program compile
The reason for this is because of the silly decision to include half of the module on the application market download, and the other half of the module in the Crestron Database itself. Whenever there
Re: Yamaha 3080 multiple connections
I think I may know what your issue is!! The module you're using has external TCP/IP input/output connections - Are you using these, attaching them to a TCP Client in the Device Symbol section?? If so,
By ckangis · #245612 ·
Re: Yamaha 3080 multiple connections
Hello ckangis, Seems like Rs232 connections are way more stable then IP connections. Those 3 I'm working on are connected via ethernet only, using 1 TCP/IP socket each on the ethernet slot of the AP3,
By Daniel Arola · #245611 ·
FS: TSW-x60 panels
Hi All, I have *(2) TSW-760-W-S?and?(1) TSW-560-B-S* All new, open box - units just have been used for a little bench testing, but basically are clean and ready to go. All include the mounting
By ckangis · #245610 ·
Re: Yamaha 3080 multiple connections
Daniel, I've been testing/refactoring my interface module for the RX-AxA series, which is ONLY IP controllable (IR of course) and I have not had any connectivity issues that you describe. I'm holding
By ckangis · #245609 ·
Re: Cisco room devices 4.0 - module cannot find the related CLZ on program compile
Copying the module and related CLZ to local folder fixed this issue. Was hoping I could use the user module folders on this PC but it still does not work correctly. Would still like to know if others
By Tray Schaeffer · #245608 ·
Cisco room devices 4.0 - module cannot find the related CLZ on program compile
Migrating to a new PC and cannot get the Cisco Room Devices 4.0 module to compile properly in my program. Opened the CiscoRoomDevicesWrapper v4.0 and cannot compile that module. Error: Statement
By Tray Schaeffer · #245607 ·
Re: Yamaha 3080 multiple connections
I am using Yamaha IP 3000 1.2. Also I opened the module in simpl to check for parameters about keep alive / connections and they are actually there. But I wasn't able to figure out a way to stabilize
By Daniel Arola · #245606 ·
Re: Alexa -> Creston integration connection system problem
I have an update about this: Removing \usr\alexaappdata files, re uploading the program, rebooting and re registering solved the problem. You still get a not connected message on echoadmin but if you
By Daniel Arola · #245605 ·
Alexa -> Creston integration connection system problem
Hello, Im losing my mind here. We have 72 devices working in a alexa-creston integrated enviroment. During logic tests the devices suddenly stopped working. After a lot of chase-tail we found a room
By Daniel Arola · #245604 ·
Re: Yamaha 3080 multiple connections
Thanks everyone, Seems like you are right about this, probably something wrong in the keep alive /reconnect logic that cant be easily fixed. Em sex., 1 de abr. de 2022 ¨¤s 03:31, Thorsten K?hler <
By Daniel Arola · #245603 ·
Re: Cisco Room Os 10
Hi Walter, Thanks for your comments. I wanted to ask if you are using the webex calls from the Crestron touch panel, trying to create a direct call to webex but I can't.
By Juan Lopez · #245602 ·
Re: Yamaha 3080 multiple connections
I agree with Steve, IR is pretty stable in general (especially via cable) and often totally sufficient, with RS232 next to the list. However, for Yamaha, i?m using the YNCA protocol and found that to
By Thorsten K?hler · #245601 ·
Re: Loading VT files to CP4
Yep, I seen this happen with several older projects.? System had been working fine for years.? I make an update to the system using newer Crestron software and all of a sudden all the iPhone/iPad
By Steve Kuehn · #245600 ·
Re: Yamaha 3080 multiple connections
I know this doesn't answer your question. But since no one appears to have an answer for your question, thought I share a little insight base on my personal past experience.? In general, I avoid
By Steve Kuehn · #245599 ·
Re: NVX vs. SVSI
Thanks for the insight, Ed ¨C very interesting. I also did some additional reading about the concept. I guess I just have too much of an Corporate/Enterprise IT background to imagine such a technique
By Thorsten K?hler · #245598 ·
Yamaha 3080 multiple connections
Hello, I'm working on a residence with 3 yamaha receivers, RX V85, RX A2080 and RX 3080. They are all using Yamaha 3010 IP v1.2 to connect and they all work fine with the xpanel app. The problem is
By Daniel Arola · #245597 ·
Re: NVX vs. SVSI
Hi Ed, Great information. Some followup questions: - Does the current VLAN switching software allow for control of multiple switches or just a "switch stack" or "virtual switch"? - I'm curious how
By FBC Tech Team · #245596 ·
Re: NVX vs. SVSI
Jeff, In 2010 we were focused on VLAN switching, as it was much faster (instant seamless switching vs slow multi-second switching on other products). We produced control system drivers to make
By eoqualls · #245595 ·
Re: Managing/Processing volume
The issue for me is all about Feedback display. Sending discrete volume levels work fine. our system uses the actual feedback of the unit to determine what the next value level will be i.e. if I send
By ckangis · #245594 ·