Keyboard Shortcuts
Likes
- Crestron
- Messages
Search
Topics in Home Automation - New Article in Residential Tech Today
¿ªÔÆÌåÓýSmart motorized shades
are a valuable addition to a smart home.? However, a consumer
has only had two choices when choosing shades:
1) Off-the-shelf
shades that have limited options and typically won't fit your
window.
2) Custom shades that
include a wide range of fabric choices, are custom cut to
exactly fit your window, and come with a premium price tag.
SwitchBot's new Roller
Shade bridges the gap between these 2 choices.? While SwitchBot
currently only offers their Roller Shade with a single fabric
choice, the shade can be custom fit by the homeowner to exactly
fit their window.? My latest article looks at this new shade
option for smart home owners in detail.
You can find the
article here:
For those interested in earlier articles
that I've written, you can find those here: |
Re: Programmatic Control of Reserved Joins
***WARNING BEFORE YOU MAKE ANY CHANGES*
**BACKUP ANY FILE INVOLVED*** **THIS MEANS CONFIG FILES AND PROJECT FILES **THIS IS FOR TESTING PURPOSES ONLY**** ****NEVER USE THIS ON A LIVE SYSTEM This procedure will allow you to add the "setup" command to Simpl. However, it's crucial to understand the risks involved. By making these changes, you could inadvertently prevent your project file from opening in the future. Here's an example of how I learned this lesson: Years ago, while working on a project with Prodigy processors, Crestron limited the number of touch panels to six. However, my project required eight panels. I was familiar with the .tio files at the time, so I decided to add a new panel. I copied the PTL4 configuration, making only the necessary changes to names and reference numbers. Then, I modified the PMC2 to support the new panel type on all Ethernet slots. This worked perfectly at first, and I completed the project successfully. However, a year later, when I revisited the project to make updates, the file failed to open. It crashed with an obscure error. Fortunately, I had documented the changes I made and kept a copy of the .tio files. Without those, I would have had to start from scratch. In the instructions below, I¡¯m referencing an existing item in the file instead of creating a stripped-down version with just the setup button. This approach reduces the risk of encountering the issue I faced after a database update. If you still wish to proceed, here¡¯s how to do it: Backup the following file: C:\Program Files (x86)\Crestron\Cresdb\Programming\symlib2.tio Edit the file using a text editor (e.g., Notepad++). Locate the following lines (current database lines 433947 & 433948): Helpers=465,633,7132,7133,7134,7135,7136,7137 Helpers6=465,633,3020,7132,7133,7134,7135,7136,7137 Modify these lines by adding ,5967 at the end of each one, so they look like this: Helpers=465,633,7132,7133,7134,7135,7136,7137,5967 Helpers6=465,633,3020,7132,7133,7134,7135,7136,7137,5967 This will allow you to add the TSW System Reserved Joins Extender to the Crestron Go definition. Within this extender, you¡¯ll find the Enter Setup join, which will exit the project and return you to the project selection page. Optional: If you prefer, you can remove ,5967 from the lines after adding the extender, should you wish to revert the change. Proceed with caution, and always keep backups in case something goes wrong. |
CP3 FW
Hi All,
I have not been updating CP4's to the latest FW versions as, though I don't use the HomeKit features, I have no confidence that there will be other issues related to the HK/OpenSSL that will bite me...?
Thus I've paused at the xxx_2.8003.00056.01.puf firmware for 4-series.
?
Regarding 3-series (CP3 primarily) I have paused at the xxx_1.8001.0251.puf Firmware.
The latest 3-series version is xxx_1.8001.0295.puf.? release notes don't mention anything about the HK/OpenSSL issue so I'm assuming that this is not an issue with this platform.
?
Can others chime in about your use/dis-use and experience with this FW version?
?
TIA!
?
? |
Re: Lutron QSX firmware update broke modules?
Was this ever resolved?
?
I am having a different issue with Comms with a currect QSX install that's been going for 3 weeks.?
?
It seems just fine on the Crestron side - I don't see any dropouts while debugging.
?
BUT Lutron is saying there are errors in communication sometimes and blaming it on the Crestron AV3 + Control Concepts 1.3 modules.
?
Theu may be full of it. Anyway here is LUTRON's assessment: " Thank you for the clarification! This definitely gives us an answer of what is happening here. It looks like the issue is stemming from the Crestron side, as the disconnects from the .80 address are showing the disconnect being unexpected with the error: Connection reset by peer.?
?
In one of the timestamps we have from the logs:
On?4/4?at 14:22 we see a successful login from the address using username SoundSight
?
On?4/4?at 15:41 the connection is read as disconnected with the error from above.
?
We're also seeing earlier on in the logs (4/4?at 14:01) times of it disconnecting and failing a TLS handshake with a timeout error."
?
?
|
Re: Crestron Home RAVA issues
The ringtone is crap. Definitely watching this thread to see if anybody comes up with a way to replace it... I'm thinking there might be another way to trigger an interrupt with logic and then tie that interrupt to one of the dozen or so additional ringtones that are exposed for the purpose of general alerts.?
?
We used to always run door control relay wires from the processor but the 2n home module (from LCD UK I believe) has come a long way... Since it is classified as a door lock in Crestron home I would think and hope and pray but not be surprised if this was not the case.. that you could set it up in 2 so when the doorbell is pressed it simultaneously rings and triggers virtual switch number four, then program the action on Crestron home side triggered from the switch 4 event to register as a door opening and that would expose the additional interrupt sounds...?
?
Course for the homeowner they probably would not love seeing the text notification that a virtual door is open while some stranger is ringing the doorbell... But if it's for your own system it just might work. Best I can do while bored in traffic...? |
Re: Crestron Home RAVA issues
The only way you can use custom ring tones is by setting the default ring tone off and then assigning a audio file in a custom project. Even if a -R panel let's you upload a custom project, it won't load it because it will have the Home App running. That says to me, no custom ring tones.
Maybe shutting the ringer off, then triggering a door bell interrupt to ring the panels might work. |
Re: Biamp Tesira v1.7 vs Biamp Tesira v3.3 Modules
It's an either-or situation - if you're wired to the Tesira by serial port, you'll use the RS-232 control processor module, but if you're connecting by LAN, you'd use the IP control processor module. If you've got both in your program, both pointed to "Control Processor 1," I bet it will confuse the other modules.? You only want to use one Control Processor module per DSP.? If you're having trouble getting it to connect to your DSP, make sure the Tesira in question has SSH/Telnet enabled (whichever you've selected to use) - sometimes they come out of the box with those disabled.
?
To my knowledge there's no way to alter an argument attribute with an analog init - that is only for analog signals/joins.? The arguments you just set during coding and to change them would require changing them in simpl, recompiling, and then pushing code again. |
Re: Biamp Tesira v1.7 vs Biamp Tesira v3.3 Modules
Thanks Gas Bandit.? I wonder if having an IP module vs the RS232 module makes any difference as far as making it easier to point to the Tesira?? In my case there is only 1 Tesira in the system, and all of the modules are pointing to CommandProcessor 1.? I just thought an Analog Init would be needed to identify that processor with the same equipment ID the programmer used elsewhere.? The IP version seems to be more direct by adding the Tesira's control IP address.
?
Anyway thanks for the info.? Very much appreciated. |
TST-1080 image resource path
I did ask this on the Crestron Discussions forum, but it seems to take days to get a response there. So posting here in the hope that you guys can help out. ? On a TSW panel, I can send an image to the panel like this: \images\icon - camera 100px wht.png The actual location on the panel is in: /display/swf/images ? On a TST, sending \images\icon - camera 100px wht.png does not work. The location on the TST where this graphic is stored appears to be: /display/app/project/assets/img Attempting to send: \display\app\project\assets\img\icon - camera wht 100px.png Yields no image ? What is the correct path to retrieve an image from the TST? ? I've tried a few combo's but nothing seems to work. |
Re: DMPS3-300-C and RS485
And yet the CP3 port (and if memory serves me correctly the PRO2 port) talks correctly...
?
They're all using MAX485 chips (or similar) afaik. I'm wondering if the issue is the timing of the DE/!RE signal.
?
Sigh. Technology! Who needs it? Oh...wait a minute...
--
Cheers Phil |
Re: DMPS3-300-C and RS485
You might need to get an oscilloscope out and compare the Tx vs Rx levels. If Tx is working, then the only thing I can think of is it is something to do with the levels. I suspect the Mipro gear, which I have not played with, is outputting something around 5v, could be ¡À5v, and your adaptors require a greater signal swing. I believe Mipro have a USB dongle to interface with their system, and I wouldn't be surprised if it doesn't meet true RS485 specs.
?
Lindsay |