Re: WiiM

 

The WIim Pro has an https api that is very limited but has some utility.? Using @TroyGarner's https utility, I was able to get some control of the device.? @JoeWhitaker, who now works at Origin, did confirm that a reworked api is in the works that is more suitable for the custom integrator.


Re: The first of what I'm sure will be many questions on CH driver development

 

Hello:

wondering if someone can help me with an issue i have with creating a .pkg file.? going through the online training and when i tried to use the Manifesutil.exe - it failed - i was able to capture the error and seems to be something to do with HRESULT: 0x90131515


Re: Anyone noticing slowdowns/failures in loading to 4-series processors lately?

 

It¡¯s interesting, I was experiencing all sorts of issues with an AV4. Very similar to what is described in this thread.?

This processor has an internal router/control subnet but we are not using it for anything. That being said, I ignored the red text in the firmware release notes that says

  • Before upgrading a router-based control system to 2.8003.00020, make sure to upgrade it to?2.8001.00098?first. Upgrading to 2.8003.00020 directly could result in the router firmware upgrade failing.

This was the case for me. The err log was always full of lines that say ¡°router GetFirmwareVersion ERROR¡± or something similar.?

I decided to do the downgrade / upgrade to latest version (v2.8003.00055). Ever since, I have not had a single issue loading programs & we haven¡¯t had to reboot the processor in a long time.?

Hope someone finds this helpful


Re: VC4 Server Name Change

 
Edited

Doug,

Thanks for the reply.

I think the server name and hostname are the same.

Can you point me to a manual or link that covers changing the hostname on a "VC-4"? I have no problems finding how to change it on the PC versions but I'm not having luck finding it for the VC4.

-JRW


Re: VC4 Server Name Change

 

Are you referring to the hostname?? If so, yes.? Just remember to generate a new Self-Signed Certificate after an IP address or hostname change as outlined in the VC4 manual.?
--
Doug G


Re: DM-NVX-363 SimplWin switching as encoder or decoder

 

So agree with u...?

"As the saying goes.. just because you can, doesn't mean you should!"?

It has no sense giving the option to a client to change a DM-NVX-363 from receiver to transmitter. Just decide the way u want to work in the project and that`s it. If you give that option there are more possibilities that the client don`t use it right and complain about the functionality.. programming is not fine.. and so on..

?


D3PRO console commands

 
Edited

Hi guys,

Working on a D3PRO project changing from a PAC2 to a CP4.? I was was looking at the SIMPL code that D3PRO generates and discovered there are some interesting console commands you can issue to D3PRO.? For example

userprogcmd "HELP"

DEBUG - State of Debug Mode

DEBUG ON - Debug On

DEBUG OFF - Debug Off

LOGGER <Args> - 'LOGGER ?' for commands

MEDIA - Report storage media

PRESET_CANCEL <Name> - Cancel a Preset

PRESET_NAMES - List Presets

PRESET_REVERT <Name> - Restore a Preset to its initial value

PRESET_RUN <Name> - Run a Preset

PRESET_SAVE <Name> - Save a Preset

PROJECTNAME - Display the project name

SCHEDULER_EVENTS - List Scheduled Event Names and Time

SCHEDULER_LOG STATE - Status of Logging Scheduled Events

SCHEDULER_LOG ON - Log Scheduled Events

SCHEDULER_LOG OFF - Turn off Logging for Scheduled Events

SCHEDULER_RUN_EVENT <Name> - Run an Event

TIMEINFO - Report current time/date info

VACATION - Report Vacation Mode

VACATION PLAY - Change mode to Play

VACATION RECORD - Change mode to Record

VACATION STOP - Change mode to Stop

VARIABLE_GET <Name> - Get a variable's value

VARIABLE_NAMES - List Variables

VARIABLE_SET <Name> <Value> - Set a variable to <Value>


And it works.? You can turn the event log on and off, list the events, and manually trigger events.? Great for confirming that your event scheduler is working.

I am using D3PRO v3.06.004.00with the latest CP4 firmware v2.8003.00055and the latest other Crestron software so I know it works with that.? And unlike previous versions of D3PRO, D3PRO now loads and put the scheduler.dat file in the right spot.

YMMV


VC4 Server Name Change

 

Is it possible to change the server name of a VC4? Thanks!

-JRW


Re: DM-NVX-363 SimplWin switching as encoder or decoder

 

We've had numerous AV Consultants specify NVX devices to be switchable from encode to decode and fortunately on every occasion bar one, we have convinced them it's a bad idea.??

As the saying goes.. just because you can, doesn't mean you should!


Re: Two homes- on SG ipad

 

Thank you Dustin for pointing out that Reserved Join for Enter Setup. Works great and I just used it today!


Re: Anyone noticing slowdowns/failures in loading to 4-series processors lately?

 

I eagerly tried?v2.8003.00055 (Mar 18 2024), still did not fix the issue
:((


Re: Colorlight Z6 control?

 

Any chance you could post some example strings from Crestron?

I'm having fun trying to make sense of the protocol manual....

Just need to switch between presets 1,2,3

SOunds like a need to send a Heartbeat packet also??

Any help much appreciated!


Elan S1616A

 

Has anyone successfully controlled one of these with Crestron?


Re: Planar PT3270Q with DGE-100

 

Awesome, I'll give them a try, thanks a lot!


Re: Planar PT3270Q with DGE-100

 

¿ªÔÆÌåÓý

Hi,

?

we?re using these:

?

They are located in Austria. If I read your domain correctly, you?re located in the Netherlands, so that should work for you.

They work great in combination with the DGE100 and have a sleek design, available in different flavors (single touch, multi touch, aluminum frame, flush mount, etc.).

I tested a couple of others brands and these came out as my favorite.

I had some issues with other brands ¨C some didn?t wake up after going to sleep.

?

HTH, Thorsten

?

?

?

Von: [email protected] <[email protected]> Im Auftrag von rogier@...
Gesendet: Dienstag, 2. April 2024 12:08
An: [email protected]
Betreff: [crestron] Planar PT3270Q with DGE-100

?

Hi guys,

Did anyone of you use the?Planar PT3270Q in combination with a DGE-100? If not, any recommendation for a fairly modern touch panel that definitely works in combination with a DGE-100?

Thanks


Re: DM-NVX-363 SimplWin switching as encoder or decoder

 

¿ªÔÆÌåÓý

Yeah, i really think they?re not designed to be switched permanently between encoder and decoder mode.

I?m wondering what the use-case is for this scenario.

?

Cheers,

Thorsten

?

Von: [email protected] <[email protected]> Im Auftrag von johnh via groups.io
Gesendet: Dienstag, 2. April 2024 16:11
An: [email protected]
Betreff: Re: [crestron] DM-NVX-363 SimplWin switching as encoder or decoder

?

Pretty sure you had to reboot them to set that change in effect- at least on the older ones.?


Re: DM-NVX-363 SimplWin switching as encoder or decoder

 

Pretty sure you had to reboot them to set that change in effect- at least on the older ones.?


Planar PT3270Q with DGE-100

 

Hi guys,

Did anyone of you use the?Planar PT3270Q in combination with a DGE-100? If not, any recommendation for a fairly modern touch panel that definitely works in combination with a DGE-100?

Thanks


Re: Sharp 4P-B86EJ2U Control

 

Hi Sean,

not sure if it applies to the 4P-B86EJ2U: we just received a Sharp display that allows selection of the RS232 protocol: "S" or "N" protocol.
The commands described above are "S" protocol, the "N" protocol is HEX.
Please check if there is a setting to switch between "N" and "S".
In addition you might want to check for Crestron Connected control. A firmware update on the display might be required to add this feature.

Best regards
Crestronfreak55


Re: Sharp 4P-B86EJ2U Control

 

I'm having this exact issue but with a 4P-B50EJ2U. Did you ever figure it out?