Re: DGE100 browser and touchpanel wake

 

Doesn?t work unfortunately - same issue. Really weird.
Another approach i wanted to follow is just to hardcode the URL into the VTPro-project.
I put an page on the project, then added the embedded browser object with a 0 visibility join, then filled in the desired URL into the object, hoping that this would just load the page and show the embedded browser.
Unfortunately, that doesn?t work, either. It shows just the empty page, but not the browser object...


Re: IP Table Offline #simplwindows

 

Don't do anything manual with the IP Table in the processor. The code will take care of that. Add the IP Table entries in your remote devices - have them point at the processor IP address or hostname if you have good DNS.?



On Sun, Feb 19, 2023, 10:53 AM <Corbin.Lovering@...> wrote:
Hello all,?
I'm a complete newbie with zero experience with Crestron products. I managed to crawl my way through P101 and 201 courses and was instructed to not go to 301 or masters without some real experience or I'll be lost and lost I am now.

I have a Pro3, CEN-SWPOE-16, TSR310 (wifi) and nothing else to play with. They all have current firmware, I've loaded my project file to the TSR and sent the compiled file to the Pro3. I've verified correct IPID's on all devices. Made sure to use the 127.0.0.1 loopback on everything. It still shows both the switch and the TSR are offline and I can clearly ping all three devices. I have a CP3 as well in case something is wrong with this processor and I was going to try both of my TSW-1060's to test with and see if I could get those online.

Is there something I can do, or possibly doing wrong?


IP Table Offline #simplwindows

 

Hello all,?
I'm a complete newbie with zero experience with Crestron products. I managed to crawl my way through P101 and 201 courses and was instructed to not go to 301 or masters without some real experience or I'll be lost and lost I am now.

I have a Pro3, CEN-SWPOE-16, TSR310 (wifi) and nothing else to play with. They all have current firmware, I've loaded my project file to the TSR and sent the compiled file to the Pro3. I've verified correct IPID's on all devices. Made sure to use the 127.0.0.1 loopback on everything. It still shows both the switch and the TSR are offline and I can clearly ping all three devices. I have a CP3 as well in case something is wrong with this processor and I was going to try both of my TSW-1060's to test with and see if I could get those online.

Is there something I can do, or possibly doing wrong?


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

On Thu, Feb 16, 2023 at 03:54 PM, <fujiakai@...> wrote:
if you have the unit, test with with Putty from you laptop.
?
the unit i have works on TCP port 23.
?
?This reply is for Fuiakai. Is your test device a 4K or a 4KZ? I tried a telnet connection port 23 on the 4KZ and the device rejected the connection.?


Re: DGE100 browser and touchpanel wake

 

¿ªÔÆÌåÓý

It¡¯s been a while but I¡¯m pretty sure there¡¯s a ¡°home page¡± serial which you can call the desired URL which won¡¯t instantiate another tab

Tim Greenbank

Control Systems Engineer


On 18 Feb 2023, at 23:06, Thorsten K?hler <thorsten.koehler@...> wrote:

?

Hi,

?

i?d like to have a DGE100 just display a single webpage.

I?ve designed a VTPro project consisting of just a single page with a browser embedded app in it.

I?m feeding the desired URL into the app and the webpage is showing up as it should.

I?ve tied the ¡°touchpanel sleep/wake¡± Manager for the DGE100 to a motion detector, so that everytime somebody enters the room, the ¡°wake¡± signal is triggered.

That works as well, the panel is waking up. However, in addition to waking up the panel, the embedded browser opens a new empty tab.

?

Any ideas why this is happening?

?

Thanks,

Thorsten


Re: Lutron Grafik Eye QS IR driver

 

Thanks Jay, but it was a false alarm. 30 seconds after I sent that post, the technician called and said they figured out the problem.

There was a serial adapter plugged into the Grafik Eye, that they later decided not to use. However, no one bothered to disconnect the un-used adapter, which apparently disables the IR jack and sensor. As soon as it was unplugged, the IR commands started working.

Hopefully this will save someone else some time in the future.

Thanks again.

--- On Saturday, February 18, 2023 at 6:12 PM, Jay Basen wrote:

Tony,

There are some Grafik Eye codes on Remote Central that might work for
you if someone doesn't have a ready made driver.



Hope this helps

Jay


On 2/18/2023 3:08 PM, Tony Golden wrote:

Does anyone have an IR driver for the Grafik Eye QS. All the ones I've found
are for the "original" Grafik Eye (not the QS) and don't seem to work.

I couldn't find an IR driver on Lutron's site, but I did find an Excel
spreadsheet with IR codes - however they're only for controlling shades, and
not lights.

The unit was previously controlled by an RTI system, but those converted
codes don't work either. I got a lot of error messages when copying the hex
codes to Deal, so I used Device Learner instead. Still didn't work...

Thanks in advance!


Re: Lutron Grafik Eye QS IR driver

 

Tony,

There are some Grafik Eye codes on Remote Central that might work for you if someone doesn't have a ready made driver.



Hope this helps

Jay

On 2/18/2023 3:08 PM, Tony Golden wrote:
Does anyone have an IR driver for the Grafik Eye QS. All the ones I've found
are for the "original" Grafik Eye (not the QS) and don't seem to work.

I couldn't find an IR driver on Lutron's site, but I did find an Excel
spreadsheet with IR codes - however they're only for controlling shades, and not
lights.

The unit was previously controlled by an RTI system, but those converted codes
don't work either. I got a lot of error messages when copying the hex codes to
Deal, so I used Device Learner instead. Still didn't work...

Thanks in advance!





Re: LCD Toshiba

 

receiving "FF" might be an indication for a wrong baud rate, maybe try different ones.

BTW: you mentioned CEC control earlier, any luck with that? Do you have something like a DM receiver that can insert CEC commands?
There are CEC modules in the database, just play with it

Best regards
Crestronfreak55


DGE100 browser and touchpanel wake

 

¿ªÔÆÌåÓý

Hi,

?

i?d like to have a DGE100 just display a single webpage.

I?ve designed a VTPro project consisting of just a single page with a browser embedded app in it.

I?m feeding the desired URL into the app and the webpage is showing up as it should.

I?ve tied the ¡°touchpanel sleep/wake¡± Manager for the DGE100 to a motion detector, so that everytime somebody enters the room, the ¡°wake¡± signal is triggered.

That works as well, the panel is waking up. However, in addition to waking up the panel, the embedded browser opens a new empty tab.

?

Any ideas why this is happening?

?

Thanks,

Thorsten


Re: LCD Toshiba

 

Hello crestronfreak55

I have also tried with this module, but without any result, I send the commands through the module and the monitor answers me FF without making any changes.

I'm starting to think there's something wrong with the monitor.


D3 Multiple loads grouped as one

 

Is there a way to group lighting loads so that D3 shows a single group vs individual loads? Essentially hiding the individual loads and only showing the group for adding to scenes and button presses?
?
for example. I have a project with LED strips in the soffits around a house that I only want to show as a single load but are connected to 4 different modules thought the project.


Re: Custom Edid file?

 

The barco is just the conferencing system running on multiple Intel nucs. (barco nodes) All linked to one another via network.? Nucs all use a Linux back end with the Barco software up front. You use whatever displays, cameras and audio you want. In our case we are using Samsung video wall displays for the meeting participants, then using a mix of Samsung qb series screens and nec screens for remote presenters, content, preview and confidence monitors.

Each display is connected to its own barco node (nuc) and I know the NUC is capable of this res, but the barco os just doesn't allow you to do it.? I have barco telling me if the node sees this res via edid, it will output what we want.?

At this stage extron edid manager looks like it might do what we need.??


Re: Need help controlling old Somfy shades via IR

 

Steve,

Thank you for following up and supplying the documentation you have.
Somfy did respond to me and they also said the high voltage relay interfaces are ESI RP60AU devices.? Based on the documentation you provided they are very similar to the SC1 if not the same thing.

On this job there is a small white box (looks like an old phone jack) that has an IR emitter from Crestron stuck to its receiver and then an RJ11 wire running to the high voltage relays.
We did learn IR codes from the old Crestron program being shot out that IR port but what we learned aren't discrete nor consistent.?

Do you know what IR codes would be used with these devices?

In the Crestron database I did find some Hunter Douglas drivers that control up to 10 different shades by ID (1-10) but I haven't had a chance to test them yet.
Looking in the Crestron database, files section here, RemoteCentral, etc... for ESI or Draper drivers I don't find anything that would control more than 1 shade.

I can post the IR codes we learned in case someone can figure something out that way.
Thanks
Dorel


Re: Custom Edid file?

 

What kind of a display technology does this Barco system use?


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

I'm currenty working with tech support on the rest API. So far they are not able to switch inputs.


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

The 4kz api is here:


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

Are you working with a 4KZ switcher or a 4k? On the 4kz, the top has been shutdown by the engineers because of security flaws. The "conf output 1 route 1" command works on the 4k but not 4kz. Extron tech support used data viewer to send that command and the 4kz rejected it.


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

¿ªÔÆÌåÓý

Wait so you have the protocol to control that switcher without needing a Crestron controller? Would you mind sharing?

Cheers

Natalie

On Feb 16, 2023, at 2:54 PM, fujiakai@... wrote:

?if you have the unit, test with with Putty from you laptop.

the unit i have works on TCP port 23.


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

if you have the unit, test with with Putty from you laptop.

the unit i have works on TCP port 23.


Re: LCD Toshiba

 

Hi Juan,

that is strange. I found a driver in the Crestron application market (for the whole TD-E series), dated back to 2016.
This driver as well states that the communication settings have to be set to serial to make serial control possible.
BTW, this driver uses different commands and states that Toshiba Rx pin is pin 2.

Don't give up (by Peter Gabriel) and good luck with the Toshiba.

Best regards