Re: LCD Toshiba

 

Those are, I suspect, Hex values, not ASCII values.? Have you tried, for instance,? \xBE\xEF\x03\x06\x00\x19\xD3\x02\x00\x00\x60\x02\x00? ? in an SIO?


On Thu, Feb 16, 2023 at 4:14 AM Juan Lopez <jlopez@...> wrote:
Hi

Im try to send rs232 commands type

ON BE EF 03 06 00 19 D3 02 00 00 60 02 00
OFF BE EF 03 06 00 19 D3 02 00 00 60 01 00
GET BE EF 03 06 00 19 D8 03 00 00 60 07 00
Also by CEC, now i want to copy the code of a command to see if i can do something



Re: Custom Edid file?

 

Hi CrestronFreak.??

The Samsung has the ability to rotate the image and stretch if required so sending it a res of 1080*1920 does work, ie, a signal from my laptop running that resolution, but I just don't have that level control over the resolution with the barco system..? They have told me they are working on this feature but it won't be ready for my deadline unfortunately!?


Re: Custom Edid file?

 

Hi Bambam_101,

using a display in portrait mode is not a matter of EDID. The video signal is still 1920x1080 and the display shows this as received. The orientation cannot be configured in the EDID.
The source needs to rotate the content by 90 degrees, that does the trick.

Best regards
Crestronfreak55


Re: LCD Toshiba

 

Hi

Im try to send rs232 commands type

ON BE EF 03 06 00 19 D3 02 00 00 60 02 00
OFF BE EF 03 06 00 19 D3 02 00 00 60 01 00
GET BE EF 03 06 00 19 D8 03 00 00 60 07 00
Also by CEC, now i want to copy the code of a command to see if i can do something



Custom Edid file?

 

Hi all. Currently doing my first Barco We Connect system and we have a Barco node (Intel nuc) that is connected to a Samsung lcd screen in portrait mode.? Problem is, there is no way to set the output resolution of the Barco node to portrait as it relies on the edid info from the screen which in this case is presenting as 1920x1080.

After lots of searches for edid emulators that will do an edid of 1080x1920, I thought about the possibility of using a TX201-C and loading a custom edid on to it.? Then placing it between the Barco node and the monitor. (using the hdmi loop out of the 201 to feed the screen.)

Having never played around with crestron edid tool before, can anyone advise if this might even be possible? I managed to have a quick look at the edid tool today but nothing jumped out at me as being able to create a completely custom edid.?

Anyone done portrait displays before and come across anything that might help me out?

Cheers


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

there is a previous thread on thsi

need add "conf" in front

ex: conf output 1 route 1


Re: Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

you can TCP to the unit on port 23. I am using a hd-md4x1-4k-e. The syntax will be?
?
>help
input <n> syncdetect <true/false>
frontpanel lock <true/false>
output <n> route
input <n> name
output <n> name
input <n> video hdcp active <true/false>
input <n> video hdcp support <true/false>
input <n> video hdcp state <int>
output <n> video hotplug state <true/false>
output <n> video hdcp disabled <true/false>
output <n> video output disabled <true/false>
output <n> video hdcp alwayson <true/false>
output <n> video cec error <true/false>
output <n> video cec sendmessage <int>
output <n> video hres <int>
output <n> video vres <int>
output <n> video refreshrate <int>
output <n> video aspectratio <int>
output <n> video deepcolormode <int>
output <n> video colorspacemode <int>
output <n> video hdcp state <int>
output autoroute <true/false>
output <n> sink manufacturer <string>
output <n> sink name <string>
output <n> sink serialnumber <string>
?


Re: D3Pro with Cameo Keypads 6Btn Issue #d3pro #cameo

 

Just trying to put back the original program like it was before.? Old Cameo for Old Cameo and New Cameo for New Cameo.? ?All 6Btns & 3Btns.? I looked on some old hard drives from jobs back in 2009 and found the file I was looking for. All my keypads have the original text on them and everything.


Re: VC-4 retrieving LPZ #vc4

 

Assuming you didn't change the default install path, /opt/crestron/virtualcontrol/ProgramLibrary/X/App, where X is the program number (sequential from 1 since you started uploading programs).


Controlling a Crestron HD-MD4X1-4KZ-E with a Extron MLC Plus 84 D touch pad using TCP or UDP

 

Hello Programmers,
Due to supply issues with the MPC3-302, our client forced us to come up with another solution.? My boss was told from a crestron rep, that extron can control the crestron switcher over ethernet using Extron's universal driver for TCP or UDP.? Is there anybody out there? (Pink Floyd ref.) with experience in this setup?? As far as what commands to send the switcher and if there is any additional setup on the switcher side?? I'm on room 1 of 40 and this is the only thing that's keeping me from moving forward.?


Re: LCD Toshiba

 

What have you tried so far?


On Wed, Feb 15, 2023 at 10:59 AM Juan Lopez <jlopez@...> wrote:
Hi,
Im try power on and off two monitor Toshiba but everthing found doesn?t work.
The model is TD-E501

If you had any information to control this it would be of great help.
Thanks


Re: D3Pro with Cameo Keypads 6Btn Issue #d3pro #cameo

 

I you problem wanting to use CBD 6 btn config (like God intended), or to swap CB models for CBD models?


Re: VC-4 USB Ethernet no longer possible #vc4

 

I have confirmed it was removed temporarily and will be back. ?


VC-4 retrieving LPZ #vc4

 

Does anyone know where the .lpz is stored on a vc4 box?? I would like to have the option to retrieve the lpz before doing things like updating the linux version or the VC-4 version, in case something goes awry.??

Thanks,
Mike


Re: Q_SYS Crestron Certified Modules version 5.0 and 5.1 #cp4 #q-sys

 

Just downloaded the 5.2 version, the PIN is back as a parameter and the seem to have fixed the library naming problem according to the release notes.

V5.0 ¨C Recompiled with Newtonsoft v4.0.8.0 for Crestron Database v200
V5.1 ¨C Various bug fixes
V5.2 ¨C Changed S# Library name


LCD Toshiba

 

Hi,
Im try power on and off two monitor Toshiba but everthing found doesn?t work.
The model is TD-E501

If you had any information to control this it would be of great help.
Thanks


D3Pro with Cameo Keypads 6Btn Issue #d3pro #cameo

 

I think I have a solution for most of my problem here,? I dug up an old D3Pro project that had 6btns on it and got an engraving file out of there. Next, I took it and put it into a different project folder changing the name of it to an existing keypad.? when I opened the that project back up I was able to program it as a 6btn keypad. This worked for me because I had an old Cameo v2 file and the keypad I was trying to program was a Cameo v2.? But now I'm searching for an original Cameo v1 (C2N-CB) file for other keypads in the project.? Anyone have the same idea or thoughts on this?? Or should a cameo v2 work in place of the original cameo if I change the button type to a v2?? I kind of think it will but I only get one shot before I screw up the original programming.? And why can't people just make archives?!


Re: Steamist port for communication

 

John,
This is not directly related to your specific symptoms, but I've found that a lot of quasi-tech devices like this have an issue with Wifi SSIDs that supply both 2.4 and 5g. If you haven't already, you might want to set up a separate SSID just for the Steamist with 2.4g only...


Re: VC-4 USB Ethernet no longer possible #vc4

 

Only on Pc3??


Re: Poly "Partner Mode" - external control?

 

It's been awhile since I tested, but I don't believe there is much control available. You have access to the commands that change the modes on the unit and query what mode it is in, etc... But nothing is really available the affects the zoom room application itself or the? video conference features when in zoom room mode.

If you have access to a unit you can use Postman to go through the api commands to verify.