Welcome to the YaMoRC/Digikeijs English Forum
?
This Table of contents provides information about the YaMoRC and Digikeijs products in US English and JMRI.
Click on the "Read More" to see all the information.
Legal notice:
All instructions are written to the best of our knowledge and belief of the respective authors.
Nevertheless, no liability for any errors or omission in the Documentation is intentional!
?
General:
The Main website of the manufacturers YaMoRC and Digikeijs can be reached via the following link:
- Link to the
- YaMoRC Support for Documents. TBD
- Link to the Digikeijs Firmware:?The latest firmware for each product will be in its respect file directory if we have the latest firmware.
- This is an archive that was made and will have documents in other languages. Check before you download.
?
US Dealers:
- for YaMoRC and Digikeijs Products.
Click on any RED Model number below, it will send you to the files page for that device.
English Only Manuals and Photos, etc can be found on this Forum and elsewhere:
Central Station:
- DR5000 The first Command Station with all conceivable connection sockets and LED status lights, USB, LAN & WLAN
- Detailed Tutorial - Rudy's Model Railway Videos on DR5000
Booster:
- DR5033 3 amp Booster works with many different Command Stations
Switch and Servo Modules:
- DK50018 16 Channel Bluetooth accessory and switching decoder
- DR4018 16 Channel Multi-Protocol Switching Decoder
- Manual: DR4018 Advanced V1.2
- Video Series for the DR4018 or DK50018 on Preset 1 in JMRI to invert the outputs for LED Signals.
-
- Guide for Testing the DR4018/DK50018 for proper Preset Configuration.?
- DR4024 4-output multi-protocol servo decoder with 4 additional switching outputs
?
Feedback Modules:
- ?DR4088CS & CS-GND 16-input feedback module (S88)
?
- ?DR4088LN-CS, LN-GND & LN-OPTO 16-input feedback module (LocoNet)
-
?
- ?DR4088RB-CS & RB-OPTO 16-input feedback module (R-Bus)
?
- ?DR5088RC 16-input feedback module with RailCom (LocoNet)
?
Reverse Loop Module
- ? DR5013
- Video :?
Turntable Module
- ??? DR5052
?
Other Equipment
- ??? DR4050 DigiLEDs RGB Model Train Light Control
?
- ??? DR5022 DigiControl for the control of 2 trains via a swivel
?
- ??? DR5039 LocoNet-B to CDE
?
- ??? DR5097 DigiNetHub 10x LocoNet Hub
?
- ??? DR5098 DigiNetHub 10x X-Bus Hub
?
- ??? DR5099 DigiNetHub 5x X-Bus Hub & 5x LocoNet Hub
Software
- JMRI
?
- RocRail
-
- ITrain
- Train Controller
- Perecli RRA (Railroad Automation)
- ?
- ?
- ?
- ?
- ?
-
- AnyRail:
Throttles:
- Document showing the Apps that work with JMRI and DR5000 with download links.
- Roco WLANmaus Throttle Setup For The Digikeijs DR5000
- Test of the Proto-Throttle with the Digikeijs DR5000
- RtDrive Lenz With The Digikeijs DR5000
- ESU Mobile Control II Throttle With The Digikeijs DR5000
- DigiTrainsPro (Android Phone) DR5000 Setup (Now a monthly fee of 5 Eros for this version)
- Z21 App for Apple or Android Phones.?
?
Other Features:
- ?
?
?
?
Re: DR4088LN-CS with DR4088CS trailing blocks turn on and off when metal wheels pass over insulated jointer
Iain
Thank you for your response. As you indicated there is no where that I have found to add a delay to prevent these nuisance detections.
I am using JMRI so I went to the sensor table/defaults/
By
Mike's DeepRun RR
·
#4761
·
|
Re: DR4088LN-CS with DR4088CS trailing blocks turn on and off when metal wheels pass over insulated jointer
In software other than JMRI (or feedbacks other than DR4088xx) this ‘bouncing’ can be cured by increasing the feedback switch-on delay slightly, from 0ms to 25ms, or even 50ms. This creates enough
By
Iain Morrison
·
#4760
·
|
DR4088LN-CS with DR4088CS trailing blocks turn on and off when metal wheels pass over insulated jointer
Thanks in advance.
When running a train with multiple cars and a single engine the first block activate as expected when the engine enters it but then when the trailing cars with metal wheels cross
By
Mike's DeepRun RR
·
#4759
·
|
Re: YD8008 with YD6940 and Kato Unitrack turnouts
Karst
Thanks for this advice I'll upgrade my PSU.
Before reading your post I'd actually come to a similar conclusion that it was a power supply issue. I was originally powering two YD8116s together
By
grahammjmason
·
#4758
·
|
Re: YD8008 with YD6940 and Kato Unitrack turnouts
There lies your problem, our experience is, that the Kato's connected to the YD8008/6940 combo need 15V PSU of about 400mA minimum.
Reason: Both YD8008 (1.2V) and YD6940 (0.7) introduce a voltage
By
karst.drenth
·
#4757
·
|
Re: DR4088LN-CS with DR4088CS some of my sensed blocks activate with just a touch of the sensed wire
I discovered tonight a wiring booboo. When I switched to tortoise switch machines I powered some of the frogs with straight booster power. So when the engine goes over the frog the power is not sensed
By
Mike's DeepRun RR
·
#4756
·
|
Re: YD8008 with YD6940 and Kato Unitrack turnouts
Iain
I took my advice from the YaMoRC website.? It clearly states that for Kato points you need to use the YD8008 with the YD6940 to convert to 2 wire from 3 wire.? I had originally thought about
By
grahammjmason
·
#4755
·
|
Re: YD8008 with YD6940 and Kato Unitrack turnouts
Graham,
I wonder if the YD8008 are the correct switches to be using with Kato turnouts. The common use for the YD8008 is power hungry solenoids such as the Peco/Seep style that need a real thump
By
Iain Morrison
·
#4754
·
|
YD8008 with YD6940 and Kato Unitrack turnouts
I'm having problems with the reliability when using this combination with iTrain. They occur mostly in automatic mode but do also? when manually operating individual turnouts or when using the track
By
grahammjmason
·
#4753
·
|
DR4088LN-CS with DR4088CS some of my sensed blocks activate with just a touch of the sensed wire
I have just discovered after adding additional blocks that some of the track when just the sensed rail is touched with my finger it will activate the sensor and generate the message of an active
By
Mike's DeepRun RR
·
#4752
·
|
Re: YD6016LN-RC
Fingers crossed that it is soon ?
By
Iain Morrison
·
#4751
·
|
YD6016LN-RC
Hello,
Is there any information when this Railcom detector module will be released?
Thanks
By
Tank
·
#4750
·
|
Re: DCC EXT DR4018?
You need a YD8116
Sent: 24 January 2025 08:34
To: [email protected]
Subject: DCC EXT DR4018?
I have a YD7001 that I believe supports DCCExt. Can I use DCCExt with a DR4018 or do I
By
Iain Morrison
·
#4749
·
|
DCC EXT DR4018?
I have a YD7001 that I believe supports DCCExt. Can I use DCCExt with a DR4018 or do I need a ?YD8116?
I use ITrain which also supports DCCExt.
Roger
By
rog.pearson@...
·
#4748
·
|
Re: DR5000 & Cobalt Problems
well well well
looks like i have the same problem with the adsx2 loosing addresses
if I use a sprogg3 the problem disapears
By
Alan Watt
·
#4747
·
|
Using YD7001 with a DR4088CS or YD6016ES
I have a small iTrain test bench layout controlled by a YD7001. To control my Blocks I have been using either a DR4088CS or YD6016ES connected directly to the EXTN88 IN port of the YD7001. Whilst this
By
Roy Endersby
·
#4746
·
|
Re: YD8116 programming
Pete
The number is, as you guessed, used with DCCExt. This allows you to use a
single address to make complex signalling done because the decoder does the
work rather than you creating a (sometimes)
By
Iain Morrison
·
#4745
·
|
Re: YD8116 programming
Hi Iain and Oldngrey,
Many thanks for your earlier replies.
Well I dived in and bought 7 x YD8116, and the USB to ES link (FTDI) adaptor, and I've had one on the bench and been playing. Thanks
By
Pete S.
·
#4744
·
|
Digitrax DS51K1 switch decoder not working with YD7010
Hi,
We are migrating from the DR5000 to the YD7010. ?We have previously controlled switch decoders with the Z21 app on iPad.
The DS51K1 decoder does not respond when connected to the YD7010. ?We
By
@Kysouthern
·
#4743
·
|
Re: How to control S88N devices with a TCS CS-105
I have a PR4, so I am considering using this as a test of whether the S88N conversation is done in the DR4088LN-CS.
thanks
--
Heath @ Human[c]ity
http://www.humancity.org ( http://www.humancity.org/
By
Heath @ Human[c]ity Junction
·