Welcome to the YaMoRC/Digikeijs English Forum
?
This Table of contents provides information about the YaMoRC and Digikeijs products in US English and JMRI.
Click on the "Read More" to see all the information.
Legal notice:
All instructions are written to the best of our knowledge and belief of the respective authors.
Nevertheless, no liability for any errors or omission in the Documentation is intentional!
?
General:
The Main website of the manufacturers YaMoRC and Digikeijs can be reached via the following link:
- Link to the
- YaMoRC Support for Documents. TBD
- Link to the Digikeijs Firmware:?The latest firmware for each product will be in its respect file directory if we have the latest firmware.
- This is an archive that was made and will have documents in other languages. Check before you download.
?
US Dealers:
- for YaMoRC and Digikeijs Products.
Click on any RED Model number below, it will send you to the files page for that device.
English Only Manuals and Photos, etc can be found on this Forum and elsewhere:
Central Station:
- DR5000 The first Command Station with all conceivable connection sockets and LED status lights, USB, LAN & WLAN
- Detailed Tutorial - Rudy's Model Railway Videos on DR5000
Booster:
- DR5033 3 amp Booster works with many different Command Stations
Switch and Servo Modules:
- DK50018 16 Channel Bluetooth accessory and switching decoder
- DR4018 16 Channel Multi-Protocol Switching Decoder
- Manual: DR4018 Advanced V1.2
- Video Series for the DR4018 or DK50018 on Preset 1 in JMRI to invert the outputs for LED Signals.
-
- Guide for Testing the DR4018/DK50018 for proper Preset Configuration.?
- DR4024 4-output multi-protocol servo decoder with 4 additional switching outputs
?
Feedback Modules:
- ?DR4088CS & CS-GND 16-input feedback module (S88)
?
- ?DR4088LN-CS, LN-GND & LN-OPTO 16-input feedback module (LocoNet)
-
?
- ?DR4088RB-CS & RB-OPTO 16-input feedback module (R-Bus)
?
- ?DR5088RC 16-input feedback module with RailCom (LocoNet)
?
Reverse Loop Module
- ? DR5013
- Video :?
Turntable Module
- ??? DR5052
?
Other Equipment
- ??? DR4050 DigiLEDs RGB Model Train Light Control
?
- ??? DR5022 DigiControl for the control of 2 trains via a swivel
?
- ??? DR5039 LocoNet-B to CDE
?
- ??? DR5097 DigiNetHub 10x LocoNet Hub
?
- ??? DR5098 DigiNetHub 10x X-Bus Hub
?
- ??? DR5099 DigiNetHub 5x X-Bus Hub & 5x LocoNet Hub
Software
- JMRI
?
- RocRail
-
- ITrain
- Train Controller
- Perecli RRA (Railroad Automation)
- ?
- ?
- ?
- ?
- ?
-
- AnyRail:
Throttles:
- Document showing the Apps that work with JMRI and DR5000 with download links.
- Roco WLANmaus Throttle Setup For The Digikeijs DR5000
- Test of the Proto-Throttle with the Digikeijs DR5000
- RtDrive Lenz With The Digikeijs DR5000
- ESU Mobile Control II Throttle With The Digikeijs DR5000
- DigiTrainsPro (Android Phone) DR5000 Setup (Now a monthly fee of 5 Eros for this version)
- Z21 App for Apple or Android Phones.?
?
Other Features:
- ?
?
?
?
DR50018 Preset 1
Hi
I'm thinking of using a spare output on my DR50018 to switch a lighting module on and off, the lighting module has its own external power source (accessory bus so about 16v DCC) and has an option
By
Matt Wolstenholme
·
#3895
·
|
Re: Feedback Sensors
I realized after I posted that there was more to discover about YaMoRC feedback modules from the manual, website and a YouTube video.
Just checking my knowledge here:
* the ES-in versions still get
By
Oldngrey
·
#3892
·
|
Feedback Sensors
Am I correct in assuming that the YD6016LN GND modules get their power from the LocoNET T cable?
If so, then how many modules can I daisy chain from the YD7001?
I envisage using a mixture of CS, GND,
By
Oldngrey
·
#3891
·
|
Difficulty acquiring locomotives with a Duplex throttle
I have a DR5000 (now a YD7001) connected to a LocoNet with a UR93 on it. I can run locomotives fine with either the DT602D or the UT6D throttles. However I can't seem to acquire the locomotives unless
By
Scott Walton
·
#3890
·
|
Re: DR4088xx S88 modules
Or get rid of the turnout position feedbacks, don’t really need occupation
feedbacks either
Many Thanks
Iain Morrison
By
Iain Morrison
·
#3889
·
|
Re: DR4088xx S88 modules
Thankyou Karst, I suspect the? 3 meter rule is the cause of the issues. this is going to be an expensive correction then as there are 11 modules on the layout handling track and turnout feedbacks.
By
Andrew Jebb
·
#3888
·
Edited
|
Re: DR4088xx S88 modules
Yes, the YD7001 Firmware can handle up to 16 modules, from which 8 are managed, the rest is unmanaged. ( managed means, the YD7001 controls what the feedbacks send to control software as well which
By
karst.drenth
·
#3887
·
|
Re: DR4088xx S88 modules
Andrew
Should be ok then, have increased the number of s88 modules in the yd7001
to cover the number of contacts you have installed?
Many Thanks
Iain Morrison
By
Iain Morrison
·
#3886
·
|
Re: DR4088xx S88 modules
Hi Iain
There are no LN modules connected the S88 units are connected into the S88 bus on the YD7001
Andrew
By
Andrew Jebb
·
#3885
·
|
Re: DR4088xx S88 modules
There is a limit of 5 x s88 modules on 1 x DR4088LN-CS
Many Thanks
Iain Morrison
By
Iain Morrison
·
#3884
·
|
DR4088xx S88 modules
I have just completed and returned a 6 board modular layout I have bult to a friend and all the track feedbacks and turnout feedbacks are handled by Digikeijs DR4088 S88 modules. I have used a mix of
By
Andrew Jebb
·
#3883
·
Edited
|
Re: Digikeijs DR5088RC RailCom LocoNet Occupancy Detector
Keep your eyes on eBay, I see them for sale quite often and recently bought another couple from there
Sent: Monday, October 23, 2023 1:21 PM
To: [email protected]
Subject: YaMoRC, Digikeijs,
By
Iain Morrison
·
#3882
·
|
Digikeijs DR5088RC RailCom LocoNet Occupancy Detector
I'm? currently using Digikeijs DR5088RC for occupancy detection and railcom feedback.? With my recent layout expansion I find myself in need of 2 more DR5088RC modules, but have been unable to
By
tabear
·
#3881
·
|
Re: Connecting Z21 app, DR5000 and Train Controller
Got it.? Thanks again.
By
John Pollard
·
#3880
·
|
Re: DR5033 Wiring to DR5088RC Diag wrong?
If you do not want to have a short on the DR5033 shutting down the DR5000,
then you can change LNCV3 to 10 on the DR5033 by using the DR5033 App.
Dennis Cherry
By
Dennis Cherry
·
#3879
·
|
Re: DR5033 Wiring to DR5088RC Diag wrong?
Thanks Dennis. Good to confirm and rule out. I had an issue in one area on the layout. It would short and shutdown. Coupled with that, I decided to move all electronics from a slide out tray to a
By
PJCwasHere
·
#3878
·
|
Re: Connecting Z21 app, DR5000 and Train Controller
You can connect via USB with a DR5000, and one protocol on WiFI/LAN - you
cannot have a different protocol on WiFi and different one on the LAN
Many Thanks
Iain Morrison
[email protected]>
By
Iain Morrison
·
#3877
·
|
Re: Connecting Z21 app, DR5000 and Train Controller
My connection to Train Controller is by usb to the PC.? If I select? the z21 protocol will that leave the loconet TC connection unaffected?
John
By
John Pollard
·
#3876
·
|
Re: DR5033 Wiring to DR5088RC Diag wrong?
The DR5033 does not have a J & K designation.?? Just wire it up as shown in the drawings.
Can you give us more information on what is your problem?
--
Dennis Cherry
Owner/Moderator
By
Dennis Cherry
·
#3875
·
|
Re: Connecting Z21 app, DR5000 and Train Controller
You can only have one wifi protocol, but can still have wired connections to Loconet and / or Xpressnet.
Mike Ruby
By
Mike
·
#3874
·
|