Re: YD7001 LAN Connection

 

I note that the default port for Loconet LBServer is described in JMRI as
being 1234.

If TC does not have the ability to change the TCP port and is hard-coded to
use the default then perhaps changing the TCP port on the DR5000/YD7001 to
1234 might allow Loconet connection between TC and the DR5000/YD7001?

Iain Morrison

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Brian A
Sent: Tuesday, September 5, 2023 11:43 PMthe DR5000/
To: [email protected]
Subject: Re: YaMoRC, Digikeijs, JMRI, English YD7001 LAN Connection

TC does have a Loconet LAN connection. I use it for another product.

Brian


Re: YD7001 LAN Connection

 

Hi Reg

Between TC, iTrain and Jmri, all 3 have a steepish learning curve.
Yesterday was the first time I played with TC since V7, it was fun, but its not for me.
I have no experience with iTrain so cant help you there, tho from what i've read in forums, people seen to like iTrain over TC? .
Jrmi is what I use, its the perfect price, more trains ;) but its not for everyone.

In the end it comes down to "The Devil you know" verses cost verses that learning curve.

Ian


Re: YD7001 LAN Connection

Reg Foster
 

¿ªÔÆÌåÓý

Hi Iain,
I agree there seems to be an issue with TC and Loconet as managed by DR/YD products. As Brian says there is facility on the TC interface for a Loconet LAN connection, as there is for the Roco Z21. But enter the exact same information and one works one doesn¡¯t . I suspect Brian is using Digitrax, not YaMoRC.?
Thanks for your input.
My next decision is do I upgrade my TC 9 Silver to 10 Gold or dump it and use the money to buy iTrain?
Onward and upward
Reg


On 6 Sep 2023, at 8:02 am, Iain Morrison <w.iain.morrison@...> wrote:

?
I am amazed that TC doesn¡¯t have Loconet TCP/IP - staggering omission.

Many Thanks

Iain Morrison



On Tue, 5 Sep 2023 at 23:04, Reg foster <Mgb074@...> wrote:
Thanks Ian,?
I changed the protocol to Z21 and bingo, all working fine.?
With that of course all the addresses in TC had to be changed from Loconet to Z21.
Thanks again, very much appreciated.?
Regards
Reg



On 5 Sep 2023, at 3:28 pm, don_chi_orchawa@... wrote:

?Hi Reg

I've spent the day learning tc10 demo,
I don't have a 7001 but i do have a 5000, it should be the same????
Below I'm accessing the 5000 via usb,
I set the protocol to z21

<dummyfile.0.part>


In TC10 I set the system to Z21, with the IP address of my 5000 and it just worked


<dummyfile.1.part>


Crossing my fingers for you Reg

Ian
Sydney


Re: YD7001 LAN Connection

 

TC does have a Loconet LAN connection. I use it for another product.

Brian


Re: YD7001 LAN Connection

 

I am amazed that TC doesn¡¯t have Loconet TCP/IP - staggering omission.

Many Thanks

Iain Morrison



On Tue, 5 Sep 2023 at 23:04, Reg foster <Mgb074@...> wrote:
Thanks Ian,?
I changed the protocol to Z21 and bingo, all working fine.?
With that of course all the addresses in TC had to be changed from Loconet to Z21.
Thanks again, very much appreciated.?
Regards
Reg



On 5 Sep 2023, at 3:28 pm, don_chi_orchawa@... wrote:

?Hi Reg

I've spent the day learning tc10 demo,
I don't have a 7001 but i do have a 5000, it should be the same????
Below I'm accessing the 5000 via usb,
I set the protocol to z21

<dummyfile.0.part>


In TC10 I set the system to Z21, with the IP address of my 5000 and it just worked


<dummyfile.1.part>


Crossing my fingers for you Reg

Ian
Sydney


Re: YD7001 LAN Connection

 

¿ªÔÆÌåÓý

Thanks Ian,?
I changed the protocol to Z21 and bingo, all working fine.?
With that of course all the addresses in TC had to be changed from Loconet to Z21.
Thanks again, very much appreciated.?
Regards
Reg



On 5 Sep 2023, at 3:28 pm, don_chi_orchawa@... wrote:

?Hi Reg

I've spent the day learning tc10 demo,
I don't have a 7001 but i do have a 5000, it should be the same????
Below I'm accessing the 5000 via usb,
I set the protocol to z21

<dummyfile.0.part>


In TC10 I set the system to Z21, with the IP address of my 5000 and it just worked


<dummyfile.1.part>


Crossing my fingers for you Reg

Ian
Sydney


Re: Connecting WLANMaus throttle to YD7001

 

So after lots of attempts, I finally got the transfer of locos between WLANMaus to work.

For future reference:

Firstly, the handsets must be connected to the command system, and the system to be turned on, for the send to start and the receive to happen.

On the Receiver, once you press OK, the Receive changes to RECV.

On the Sender, once you press OK, the display scrolls through the List of Locos. Once this happens the Receive handset also scrolls through the list of locos.?

THIS DOESN'T WORK WITH THE YD7001. Once I connected both handsets to a z21 Start it worked.?

On the YD7001 the Send works but the Receiver just stays on RECV.?

Hope that helps someone else in the future.

Regards Brian


Re: YD7001 LAN Connection

 

Hi Reg

I've spent the day learning tc10 demo,
I don't have a 7001 but i do have a 5000, it should be the same????
Below I'm accessing the 5000 via usb,
I set the protocol to z21



In TC10 I set the system to Z21, with the IP address of my 5000 and it just worked




Crossing my fingers for you Reg

Ian
Sydney


Re: Connecting WLANMaus throttle to YD7001

 

So having been following this thread I decided to update the firmware in my 3 WLANMAUS this morning. So all failed on multiple attempts. I ended up trying 3 different WIFI routers for the Maus and the PC and using the Maintenance app and finally got all 3 upgraded. However in the process, 2 throttles lost all their locos, about 30 locos.

I have tried do do the send - receive to transfer the locos from the Throttle that has all the locos to the other two but it doesn¡¯t appear to work. Receive starts scrolling on the receivers, but pressing OK when on SEND on the transmitter does nothing. Am I missing something?

I have an operating session on Friday so if I don¡¯t get it to work, it will take me a while to enter 60 locos.

Brian


Re: YD7001 LAN Connection

 

Hi Don
Thank you, the YD 7001 is now working a treat with the PC interface by changing the Ethernet Properties to 192.168.0.93. Thanks again. Now to get Traincontroller communicating via LAN. Iain says the Port needs to be changed, but I haven't found where to do that yet. You were a great help
Regards
Reg


Re: YD7001 LAN Connection

 

Hi Reg

going by the Pic's, did you set both the computer and the 7001 to the same IP address?

Change 1 of them to say 192.168.0.93


September 4, 2023 Open Meeting 1:00PM-5;00PM CDT

 

Yesterday we had some interesting conversations.

Had the Engineer that designed the TCS Throttles.? We learned a lot.

Worked on some product issues.

One topic came up to make a spreadsheet of comparing the Digikeijs products numbers to the YaMoRC product number.
Also add the latest revision numbers to the spreadsheet.
If you want to volunteer for this task let me know.




--
Dennis Cherry
Owner/Moderator-


Re: YD7001 LAN Connection

 

is there away to use loconet over IP on traincontroller I did not think there is


On Mon, Sep 4, 2023 at 9:23?AM Iain Morrison <w.iain.morrison@...> wrote:
No, in TrainController. The DR5000 used 5550 as the Loconet TCP port, YAMORC
uses 5560 by default as the TCP port.

If you have TC setup for a DR5000 then you could change the port in the
YD7001 to 5550 to regain connectivity - BUT be aware that this could have
consequences when upgrades are applied if they change the port back to 5560.
Best to change it within TC - though not being a TC user I don't know where
that change would be made, I would think somewhere in the interface
definition.

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Reg foster
Sent: Monday, September 4, 2023 9:19 AM
To: [email protected]
Subject: Re: YaMoRC, Digikeijs, JMRI, English YD7001 LAN Connection

Thanks Iain,
Do you mean here
Reg












Re: YD7001 LAN Connection

 

No, in TrainController. The DR5000 used 5550 as the Loconet TCP port, YAMORC
uses 5560 by default as the TCP port.

If you have TC setup for a DR5000 then you could change the port in the
YD7001 to 5550 to regain connectivity - BUT be aware that this could have
consequences when upgrades are applied if they change the port back to 5560.
Best to change it within TC - though not being a TC user I don't know where
that change would be made, I would think somewhere in the interface
definition.

-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Reg foster
Sent: Monday, September 4, 2023 9:19 AM
To: [email protected]
Subject: Re: YaMoRC, Digikeijs, JMRI, English YD7001 LAN Connection

Thanks Iain,
Do you mean here
Reg


Re: YD7001 LAN Connection

 

Thanks Iain,
Do you mean here
Reg


Re: YD7001 LAN Connection

 

Have you set the port for loconet to 5560?

Many Thanks

Iain Morrison



On Sun, 3 Sep 2023 at 23:58, Reg foster <Mgb074@...> wrote:
Greetings All, I have returned from my holiday and think I have followed your advice Karst. I have found the ip address of the YD7001. 192.168.0.94, set that in the Track Go/Stop tab, entered the ip, subnet mask, and Default Gateway into Windows 10 Ethernet settings. Ensured the YD LAN settings in the YD are STATIC, connected track and a bright yellow Ethernet cable and bubkiss, zip, naught, nothing. So I loaded the ip address into Traincontroller 10 Gold, it told me to consult a computer expert. Well here I am folks. I will post some pics to show the setup. I humbly ask for assistance please.

Attachments:
image1.jpeg: /g/Digikeijs/attachment/3661/0
image2.jpeg: /g/Digikeijs/attachment/3661/1
image3.jpeg: /g/Digikeijs/attachment/3661/2
image4.jpeg: /g/Digikeijs/attachment/3661/3
image5.jpeg: /g/Digikeijs/attachment/3661/4






Re: YD7001 LAN Connection

 

Greetings All, I have returned from my holiday and think I have followed your advice Karst. I have found the ip address of the YD7001. 192.168.0.94, set that in the Track Go/Stop tab, entered the ip, subnet mask, and Default Gateway into Windows 10 Ethernet settings. Ensured the YD LAN settings in the YD are STATIC, connected track and a bright yellow Ethernet cable and bubkiss, zip, naught, nothing. So I loaded the ip address into Traincontroller 10 Gold, it told me to consult a computer expert. Well here I am folks. I will post some pics to show the setup. I humbly ask for assistance please.


Re: Connecting WLANMaus throttle to YD7001

 

Bernhard

Yes, you are correct.? I missed that.? You can directly start the WLANMaus Update Tool application, and there is no need to use z21 Maintenance Tool to update the WLANMaus. Again I learn something new :-)

When I was trying to figure out the update process for the WLANMaus I found and watched a You Tube video done by a German modeler and he always started at the z21 Maintenance Tool?probably because he has other Z21 components to maintain.

Jay Lennox - Toronto


Re: Meeting Room Sept 3, 2023 Starting 1:00 PM CDT

 

Dennis,

Thank you for setting this up. It was very nice to meet everyone on the call.

Thanks,
Stuart


Re: Connecting WLANMaus throttle to YD7001

 

Hi Jay,
after having succesfully updated my WLANmaus using your information (thanks for this!) I think installing the z21 Maintenance Tool is not necessary. The option for WLANmaus update in the maintenance tool is just starting the WlanMausUpdate.exe program and thus it should be possible to start WlanMausUpdate.exe without the detour via z21 Maintenance Tool. That is the way given in the german instructions who are included in the WLANmaus update tool.

Kind regards
Bernhard