Re: yd7110
Now that the MRR season is a bit "over", we start working our as*&*s off on this one: This will become our "Entry-Level" Command Station. Basic functionality equals the YD7001-E. And has even more
By karst.drenth · #4271 ·
Re: DR4088LN with JMRI
Nope, the sa called "Inquiry" requests are not honoured by the DR4088LN.? Alternative is sending a GP_ON on the LocoNet Greets, Karst
By karst.drenth · #4270 ·
Re: DR5033 Digiboost
Karst, over looked the other internal component failure, with the 7805 failure that could cause other parts to fail. The history of the P/S make sense and wonderfully explained by you. Thank
By Dennis Cherry · #4269 ·
Re: DR5033 Digiboost
Well, I do see a bit more than "just" a blown 7805. Further, in Europe ( maybe because we have 230VAC on our outlets ?? ) an number of those old PSU's caused a) fire ? and b) sponteaneously
By karst.drenth · #4268 ·
Re: DR5033 Digiboost
When I started using the Digikeijs Products around 2017, the Power Supply's all had the voltage selector switch, then Digikeijs changed to fixed voltage power supply's and only had the 16 & 18 volt
By Dennis Cherry · #4267 ·
Re: DR5033 Digiboost
Did Digikeijs change the power supply over the years? I don't see any variable voltage capabilities on the ones I have. The DR5033 and DR5000 I bought all came with MeanWell GST60A15-P1J power
By Oldngrey · #4266 ·
Re: DR5033 Digiboost
Thanks Dennis for your input George
By GMB Rail Systems · #4265 ·
Re: DR5033 Digiboost
All electronics have failures. 7805 Regulars are produced by the billions over the years. Equipment is always sent back to the respective companies for repair, most are just tossed by the user and
Re: DR5033 Digiboost
Bob, thanks for asking the question as I would like to know as well. -- Heath @ Human[c]ity http://www.humancity.org ( http://www.humancity.org/ ) http://www.riversidetransfer.nyc (
By Heath @ Human[c]ity Junction · #4263 ·
Re: DR5033 Digiboost
Would you recommend replacing these power supplies? If so, is there a recommended replacement or specifications for one? Regards, Bob Gamble
By Bob Gamble · #4262 ·
Re: DR5033 Digiboost
Thanks Karst George
By GMB Rail Systems · #4261 ·
Re: Access to yamorc.de site for activation code
You got the reason in FB Messenger ;)
By karst.drenth · #4260 ·
Re: DR5033 Digiboost
Correction: Since the LM7805 also has a crater, it has been massive overvoltage from the powersupply. This typically happens with the Digikeijs Adjustable Powerbricks.... known problem.
By karst.drenth · #4259 ·
Re: DR5033 Digiboost
Looks like either a Powersupply that went bazooka's Or there was a massive external powersource connected to the TrackOut ...
By karst.drenth · #4258 ·
Re: YD9401: LAN DHCP choice when STATIC (Fixed IP) in web interface
Thank Iain, that's correct. The webInterface is unfortunately not yet completely functional. Greets, Karst
By karst.drenth · #4257 ·
Re: DR4088LN with JMRI
...I posted this question on the JMRI group as well
By Vinny DeRobertis · #4256 ·
Re: YaMoRC WiThrottle protocol
Thanks, But unfortunately I see no evidence of the Short in the Log :'(
By karst.drenth · #4255 ·
DR4088LN with JMRI
I am using DR4088LN (LocoNet) Input Modules and the 'Request update of all sensors' LogixNG action does not seem to work. I have the Logix NG setup to Run once upon startup. Can anybody verify
By Vinny DeRobertis · #4254 ·
Re: Access to yamorc.de site for activation code
I have similar issues with the link to the registration site. In MS Edge, Google Chrome and the Ipad browser I get: **** Not Found **** The requested URL was not found on this
By rzwartus · #4253 ·
Re: YaMoRC WiThrottle protocol
Karst, If you could take a first look at this log, I can dig a bit dig a bit deeper on the UWT side if you find something interesting. Thanks, Stuart
By Stuart Baker · #4252 ·