Re: upgraded DR5000 to YD7001 throttle issue
Thanks for the thread, it appears there was no resolution to the issue. I figured quickly that after acquiring the locomotive I was able to use the 602D wirelessly for control. Seems like a conflict
By David Betz · #4822 ·
Re: Can the YD7001 be used for setting CVs on accessories ?
Nope, that is not unclear ;) As of LocoNet specs, RailSync ( which drives the boosters ) must be a carbon-copy of what the commandstation sends to the track. And so it is done by our command stations,
By karst.drenth · #4821 ·
Re: Programmer Busy reading CVs with Ops mode over Railcom with YD9401
Lower this setting: (POM packet repeat count) ... until it completely stops reading. My experience is that 2 or 3 are a good value. Unfortunately JMRI does *not* handle "Busy" with a retry of the
By karst.drenth · #4820 ·
Re: Programmer Busy reading CVs with Ops mode over Railcom with YD9401
Scott, There are many factors that can impact the speed of reading when using PoM, amongst them being how busy the track is i.e. how many other locos are present, with special consideration as to
By Iain Morrison · #4819 ·
Re: upgraded DR5000 to YD7001 throttle issue
I think this is the same as previously discussed. A search in this forum for DT602D found this thread: /g/YaMoRC-Digikeijs/topic/102227767#msg3973 I don't think the DR5000 was
By Oldngrey · #4818 ·
Programmer Busy reading CVs with Ops mode over Railcom with YD9401
I have a DR5000 which has been upgraded to a YD9401. When I use DecoderPro with Programming on Main to read Read All Cvs, I get many "Programmer Busy" responses. The LocoNet log shows that the Write
By Scott Walton · #4817 ·
Re: Can the YD7001 be used for setting CVs on accessories ?
Jay, Just select the Loco PoM or Accessory PoM radio button on the YD7001 programming interface, enter the address for the device, the CV number and then the value. You will need to try both
By Iain Morrison · #4816 ·
Can the YD7001 be used for setting CVs on accessories ?
Hi We will shortly have 6 circuit breakers installed on our club layout.? I am giving each of them a unique accessory address before they are installed. I am trying to determine if the YD7001 can
By Jay Lennox · #4815 ·
Re: Resistor for block detection, best size?
Whist iTrain can calculate the train length placing resisting axles at the back of trains lets iTrain see the back of the train - especially useful for reversing or if you lose part of the train
By Iain Morrison · #4814 ·
Re: Resistor for block detection, best size?
Thanks for that Iain.? Would you add the resistors to wagons when using iTrain as the length of the loco/wagon combination is calculated by iTrain?
By alanmayfield@... · #4813 ·
Re: Resistor for block detection, best size?
The resistor axles have no impact upon Railcom and simply provide occupancy for the wagon. FYI Railcom has nothing to do with occupancy, it is simply reporting the details from the decoder. The
By Iain Morrison · #4812 ·
Re: Resistor for block detection, best size?
I use iTrain with DR5088RC but don't have axle detection for wagons.? I can understand how resistors would work for current detection, I don't understand how they work with Railcom as resistors are
By alanmayfield@... · #4811 ·
upgraded DR5000 to YD7001 throttle issue
I recently upgraded my DR5000 to a YD7001. Everything went according to plan and I now have WIFI working. I use Digitrax DT602D throttles and a Digitrax UR93 radio. The problem is that I now have to
By David Betz · #4810 ·
Re: Mounting the YD6940
Don't discount hot glue ht glue. It's super easy & I use it everywhere with success.
By Ray Jorgenson · #4809 ·
Re: Mounting the YD6940
Thanks for the suggestion. I dunno why I didn't think of zip ties on mounts before. On order now.
By Oldngrey · #4808 ·
Re: Mounting the YD6940
I use the small zip tie mounts that I screw to the bottom of the baseboards and then use zip ties to hold them up. The mounts come with sticky tape but I use the screw hole. Mike -- Mike's Deep Run
By Mike's DeepRun RR · #4807 ·
Mounting the YD6940
I have been using the YD6940 3 to 2 wire adapter to power my Tortoise switch machines with the YD8116. They work well electrically, but I would like some advice on how to best mount the things rather
By Oldngrey · #4806 ·
Re: DR5000 help needed
Hi Thanks. This worked though I had to do it a few times, trying each of the other protocols before going back to Z21. My DR5000 had XpressNet LAN LocoNet over TCP/IP LBServer Dr.Command LocoNet
By Chadbag · #4805 ·
Re: DR5000 help needed
Hi, Resetting the RM04 module caused the evil. Now the DR5000 and the module disagree about which protocol is to be used. ( because of the factory reset ) Fix: 1. Set the Protocol to TCP/IP
By karst.drenth · #4804 ·
DR5000 help needed
Hi All I’ve taken about 2 — 2 1/2 years off from model railroads as I was contracting and building a house for my family (and still had my day job). I have a Digikeijs DR5000 command center.
By Chadbag · #4803 ·