Re: yd6016es problem


 

what i mean by out of sink is

if you open up the yd7001 software click on the exts88 and click on feedbacks?

follow the numbers down until you come to number128 the next number should be 129 but it shows 128 the next number should be 129

On Tue, May 28, 2024 at 2:28?PM karst.drenth via <karst.drenth=[email protected]> wrote:
On Tue, May 28, 2024 at 04:28 AM, Alan Watt wrote:
is there a bug in the software

Nope, works as designed. But....

?

The YD7001 can fully configure and address 1-128 inputs (8x 16-bit modules) Modules above are run in "legacy mode".

?

That means that they get numbered as if it were in the DR5000 --> "First contact in feedback space" + 128? for the 9th module upwards.

?

So if you want to use more than the recomended 8 modules you are more or less obliged to follow the legacy numbering scheme.

?

That is:?

?

"First contact in feedback space" set to 0 and answer Yes to the automatic renumber question.

?

i dont?understand what you mean about out of spec when you said it was 5 mtr cable length?from the yd7001


Our spec is a guaranteed maximum of 3 meters, as is the original M?rklin spec for the s88 Bus. Provided that all YD6016ES modules are contiguous connected from the command station on. "non ES-Link modules (i.e. DR4088) should be connected AFTER the last ES-Link Module. This is required, since DR4088 do not carry the ES-Link signals "upstream" to the later modules on the string.

?

I mentioned 5 meters, because some people her and in other fora reported 5 or more meters also working. But it's in the range of "getting luky when it works".?

Greets,