Re: double traces/lines in tektronix 577 curve tracer
I remember frying some diodes during lunch on a brand new 575 in a class. Teacher walked by and said what are you doing? I and classmate said burning up some diodes. Good, good, he said, knowing we
By John Hancock · #208875 ·
Re: More 2465B SRAM Trouble
Not sure what you mean regarding the accessory boards/widgets. This is the exact package I bought: https://amzn.to/3DBlYq9 I bought the one with the extras since I wanted them for other things in the
By pac1085 · #208874 ·
Re: Tek 2236 Control Button Error
Well... Not a cleaning problem. Actually a broken actuator inside the "CH1V" switch section, it was the internal actuator position that was unreliable, not intermittent contacts. So, it will be
By George Werl · #208873 ·
Re: 2465B which are my options for the SRAM "problem"? low serial with OPTION 5:)
Hi Sigur?ur, Yes, but according to the manual,should have a different designation, not "A/B TRIG" but "A/B MENU", also B TRIG options seems different. It is almost impossible to tell if there is a
By Giuseppe Marullo[iw2jww] · #208872 ·
Re: Tek 492 Y axis failure?
Hi again. To finish off this thread. For whatever reason, the 'spare' CRT damaged the video board, revealing that the CRT is dead and may well have been why the 2nd 492 had been stripped down
By James55 · #208871 ·
Re: More 2465B SRAM Trouble
Craig, no joy with the EXER 03 sequence, tried it a couple times. Same error - 04 Fail. I did notice when I clear by pressing A/B TRIG, I get 4 CRT lines and gibberish on the bottom of the
By Ron Jones · #208870 ·
Re: More 2465B SRAM Trouble
May not be related but I had a lot of trouble with the GQ-4x4 and my 2467B when replacing the Dallas chip. I went with the GQ since I watched a YouTube vid where someone used one successfully with a
By pac1085 · #208869 ·
Re: More 2465B SRAM Trouble
Ron, Try this exercise to see if this clears up your issue. Its a specific button push in the correct sequence. CYCLE ERROR CLEAR (Exerciser 03). This routine provides a way for the operator to
By Craig Cramb · #208868 ·
Re: 5L4N manual (not 'interim')
Hi, The manual doesn't look like the "interim" one: https://w140.com/tekwiki/images/8/81/070-1733-00.pdf They've updated the pdf file I guess. I also have the pdf from Artek, it looks
By Ke-Fong Lin · #208867 ·
More 2465B SRAM Trouble
I bought a no error codes on startup S/N B057443. Inspection of A5 showed no leaking of the SMD eCaps, but the Dallas DS1225Y was 1991 vintage by date code. I bought a new Dallas DS1225AB-200+ from
By Ron Jones · #208866 ·
Re: double traces/lines in tektronix 577 curve tracer
It’s the effect of internal capacitance in the device and/or heating/cooling of the semiconductor junction.
By Dave Voorhis · #208865 ·
Re: VintageTEK demo boards are back
Dave: I will make another round of them. April 5th is not far off but it's possible they could be ready for purchase then. -Thomas
By Mr. Fang · #208864 ·
Re: VintageTEK demo boards are back
Thomas! I will be visiting the museum on April 5th!!! Is there any chance you can save me one?!?!? - Dave KQ4VBE
By @ICY.dev · #208863 ·
Re: 2465B which are my options for the SRAM "problem"? low serial with OPTION 5:)
Thanks Alex, 1) could you please confirm that your 2465B has a low serial? If so you should have performed the battery mod, else it should fail the battery voltage check, right? I saw that the
By Giuseppe Marullo[iw2jww] · #208862 ·
double traces/lines in tektronix 577 curve tracer
Hi, Can anyone explain why my Tektronix shows double curves in each step when I testing transistors? thank you! /g/TekScopes/album?id=301335
By richar926@... · #208861 ·
Re: Looking for Tektronix VM700T Software
Perfect. I sent you my SN info directly, hope it helps.
By Tim Wright · #208860 ·
Re: Dennis Tillman Tek 575 Curve Tracer Adapter PCB?
I am very interested in the tube adaptor for my 575. I was not aware a tube tester was not needed. I do have a couple Sencore testers. John
By John Hancock · #208859 ·
Re: 2465B which are my options for the SRAM "problem"? low serial with OPTION 5:)
I do have a 2465B with a FM16W08 FRAM and so far it has worked perfectly for several years. Plug-n-Play without any special mods or anything else but to mount the FRAM on an SOIC to DIP28 adapter, and
By Alex · #208858 ·
Re: 2465B Screen artifacts
Hey there Hachiroku, nice to meet you, welcome to the group :). <chester.jamie.jammy@...> wrote: I guess one other thing to check is whether J504 is in the correct position, it
By Sigur?ur ?sgeirsson · #208857 ·
Tektronix 2236
I need plastic cover box #342-0592-00 for Tektronix 2236 which is on the multmeter board. Does anybody have one to sell.
By lbrown8008 · #208856 ·